Denis E. Bergeron 2026-11-05
Denis E. Bergeron is a NIST research chemist in its Radioactivity Group whose work concerns physical radioactive activity measurements and standards. His official profile identifies his work in that group; an author account in the Journal of Research of NIST documents the comparison of primary activity standards over several decades.[ref][ref]
Figure 1.
Denis E. Bergeron, from his labeled NIST staff portrait
. Source.
In the 2014 coauthored review, Bergeron and colleagues examined ten fluorine-18 standardizations from 1982 to 2013. A new standard differed by about 4 percent from results obtained in1998–2008. The authors compared multiple primary measurement methods and possible sources of bias, while explicitly reporting that the older discrepancy was not fully explained.[ref]
A simple ionization chamber example shows why a calibration difference matters. Suppose measured electric current is and the response model is . A hypothetical factor gives activity . Replacing it by gives approximately for the same current, an increase of about .
These numbers are invented, not the review's calibration table. They separate the detector observation from the inferred radioactive activity. Bergeron's standards work demonstrates why cross-method comparisons and an explicit measurement uncertainty budget matter even when repeated readings are consistent.
Eduardo García-Toraño 2026-11-05
Eduardo García-Toraño is a physicist whose work includes precision measurements of radioactive decay. His 2010 coauthored study of fluorine-18 lists an affiliation with an ionizing radiation metrology laboratory in Madrid. The experiment followed radioactive decay using three systems: ionization chambers, germanium detectors, and coincidence counting with fast scintillators. Measurements extended over as many as nine half-lives, providing several instrumental routes to the same physical parameter.[ref]
The combined result was a half-life of , where the parenthetical notation represents in the last quoted digits. This is the result reported by that experiment; the distinction matters when comparing a historical measurement with a later evaluated half-life.[ref]
A simple model illustrates why the long observation interval is demanding. Suppose a detector's observed event rate is
where is the radioactive decay constant and is a constant instrumental background. This illustrative model assumes stable detection efficiency and background. After nine half-lives, the decaying contribution is . An initial contribution of events per second would therefore fall to just event per second: even a small background can then noticeably distort an exponential decay fit if it is omitted. Independent detector systems make a valuable comparison because their instrumental backgrounds and responses need not behave identically.
Fluorine-18 2026-11-05
Fluorine-18 is a radioactive isotope of fluorine with 9 protons and 9 neutrons. It decays to oxygen-18, mainly by emitting a Positron and also by electron capture. Its approximately 110-minute half-life makes its radioactivity change appreciably over an ordinary laboratory session. It is used in positron emission tomography.[ref]
The half-life can be measured by following the falling radioactivity, rather than by watching one nucleus wait to decay. A 2010 experiment used ionization chambers, germanium detectors and coincidence counting with fast scintillators, following decay for up to nine half-lives. The combined result was . Comparing different detector systems tests whether the inferred decay rate depends on one measurement technique.[ref]
For a closed sample governed only by radioactive decay, the surviving parent fraction is . Taking 110 minutes as an illustrative rounded half-life, 220 minutes leaves one quarter of the original fluorine-18 nuclei. Four half-lives leave , not zero. This calculation concerns nuclear survival; movement of a labelled molecule into or out of an observed region is an additional process.