Nonuniqueness of pulse energy at fixed peak power and FWHM means that those two measurements do not determine the integral of an otherwise unspecified power profile. The pulse energy shape factor gives a rectangular/exponential counterexample. A stronger original construction shows there is no finite universal upper bound without restrictions on lower-level tails.
Fix , power FWHM , and . Choose any . Let the power equal for , equal for , and zero afterward. The optical pulse pedestal is part of the stipulated signal, not an unrelated background. Its level stays below half maximum, so the peak and FWHM remain unchanged, butWith and , the energy is , compared with for the pedestal-free rectangle. Increasing finite gives unbounded pulse energy at fixed peak and FWHM across this family of finite-duration ideal profiles.
This is an identifiability result, not a claim that a particular laser has arbitrarily long tails. The primary source definition of power-FWHM fixes a threshold width, not the integrated energy below that threshold.[ref]
Plane wave and beam source - Simulation object in Ansys Optics documentation. PULSELENGTH definition
A measured full profile, a justified shape family or additional tail-duration bounds supply information that peak and FWHM omit. Optical energy outside a time gate 2026-11-05
Optical energy outside a time gate is the radiant energy excluded by a specified ideal temporal acceptance set . For a nonnegative radiant power profile of finite positive total energy,The time-integral definition is the radiometric one.[ref]
International Lighting Vocabulary by CIE. entry17-21-041, note1, radiant energy as the integral of radiant flux
This observable needs a gate boundary but no fitted separation into a main field and an optical pulse pedestal.For an original three-pulse example, let an optical prepulse, main pulse and optical postpulse carry , and respectively, with disjoint supports. A gate containing only the main pulse admits of , so . Widening that gate to include the postpulse reduces the fraction to . The optical waveform has not changed; the admitted observable has.
For a translated interval with continuous boundary values,Unequal power at the boundaries produces first-order sensitivity to a timing shift. Equal boundary values eliminate this derivative but need not eliminate higher-order loss; quadratic energy loss from centred Gaussian gate timing error gives an existing example.
The total-energy denominator must cover the excluded light too. If the acquisition window misses an unknown tail, pulse-energy interval from incomplete tail measurements supplies conditional bounds rather than an exactly known fraction. A detection time gate on an electrical detector trace also includes the detector impulse response and is not automatically an ideal gate on incoming optical power. A characterized optical response and a stated detector baseline subtraction are needed to compare the two.
Optical postpulse 2026-11-05
An optical postpulse is a secondary optical pulse arriving after the chosen main pulse. Specify the delay, relative peak radiant power, duration and collected laser pulse energy: a relative peak alone does not determine the energy of a differently shaped replica. It is distinct from an extended optical pulse pedestal and from electronic ringing from a photodetector.
A transparent plate provides a concrete mechanism. At normal incidence, a transmitted replica that makes one additional internal round trip has approximate delaywhere is plate thickness and is its group refractive index. Neglect absorption, dispersion and overlap, and let each internal reflection retain power fraction . The first delayed replica then has approximately times the directly transmitted energy. This etalon round-trip delay can create a physical optical echo.
For an original chosen , and , the delay is about and the energy ratio is . A main pulse would be followed by a replica under that model. The historical single-shot correlator experiment deliberately inserted a BK7 etalon to generate and detect such a delayed pulse.[ref]
A Single Shot 3rd Order Cross-Correlator for Pulse Contrast and Pulse Shape Measurements by J. Collier and others. printedp195, Results and Figure4, double-reflection postpulse near1.5×10^-3
Changing the plate thickness tests the delay prediction; changing optical alignment tests whether a stray reflection is involved. A third-order intensity autocorrelation can distinguish temporal sides under its model, while a symmetric second-order intensity autocorrelation cannot alone assign a feature to a prepulse or postpulse. An opposite-delay correlation feature may instead be a third-order pulse correlation ghost; it need not identify another physical pulse.
Optical pulse temporal contrast 2026-11-05
Optical pulse temporal contrast compares a pulse's peak with weaker light at another time. For a radiant power trace with peak , explicitly choose either the peak-to-local ratio or its inverse . The first is at least one where the local power is positive; the second lies between zero and one. With a fixed transverse beam shape, the same ratio can be formed from light intensity. If the beam shape changes with time, specify the spatial sampling instead of identifying local intensity and total power.
A plateau at of the peak has and . Expressing this power ratio as optical contrast in decibels givesFor an amplitude ratio whose power ratio is , the same definition gives . Contrast also needs a delay or time range: an optical prepulse, an optical postpulse and a long optical pulse pedestal can have the same relative height but different positions and laser pulse energies. The pedestal energy fraction additionally requires integration over the contribution's duration.
A useful nonlinear measurement is third-order intensity autocorrelation. In an ideal instantaneous model, an input light intensity generates a second-harmonic gate proportional to . Sum-frequency generation with a delayed fundamental replica gives a recorded signal proportional toThe instrument measures this cross-correlation, rather than simply reading . Finite gate width, phase matching, spatial overlap and detector response enter the interpretation.
The1998/99 instrument of J. Collier and colleagues used second-harmonic generation, a Wollaston prism and an optical biprism to form crossing fundamental and harmonic beams. A second crystal generated the sum-frequency signal, imaged through optical filters onto a charge-coupled device. Position encoded delay. An inserted glass etalon produced a delayed replica near of the main signal, recorded on one side of the correlation peak. Figure4 combines window settings shifted with etalons.[ref]
A Single Shot 3rd Order Cross-Correlator for Pulse Contrast and Pulse Shape Measurements by J. Collier and others. Printedpp194–195, Description/Figure2 and Results/Figure4
An independent ideal calculation explains both the asymmetry and a possible third-order pulse correlation ghost. Let represent two identical-shape pulses with well-separated supports and correlation lobes, with the second weaker and delayed. Squaring introduces no overlap term. If , expansion givesThe delayed replica produces a lobe of relative order , while the opposite-delay ghost has order . For , the scales are about and respectively. These values are predictions of the stated ideal model. Assigning every small correlation feature directly to a separate input pulse would miss this distinction.
A nondetection below the measurement floor establishes a bound under a detection model, rather than demonstrating that no light exists there. Finite dynamic range, detector baseline subtraction, delay coverage and resolution should accompany a reported contrast trace. The Sequoia manufacturer likewise distinguishes optical temporal resolution from the scan step; making that step smaller does not alone narrow the optical response.[ref]
Sequoia temporal contrast measurement by Amplitude. January2024 sheet, PDFp2, Specifications
Pedestal energy fraction 2026-11-05
The pedestal energy fraction is the fraction of an optical pulse's laser pulse energy assigned to its optical pulse pedestal. Specify the decomposition and integration interval before quoting it. For a nonnegative additive radiant power model ,The assumptions imply by integration. A pedestal fit is a model of the measured radiant power; it is not automatically a unique physical separation into optical fields. Overlapping fields with optical coherence can have wave interference terms, so their separate field energies cannot generally be added as though those terms were absent.
The distinction from optical pulse temporal contrast is quantitative. Use the stipulated rectangular model of optical pulse pedestal: a main contribution has height and duration , while a centered pedestal has height and duration . For , the total peak is and the power full width at half maximum remains . Define peak-to-pedestal contrast . ThenHalf the laser pulse energy is in the modeled pedestal when . A large peak-to-pedestal ratio therefore does not by itself imply a small energy contribution.
For an original comparison, fix and the same in both traces. With , the pedestal fraction is ; with , it is . Thus the same contrast and power FWHM can coexist with about1% or50% pedestal energy. At fixed finite , increasing the pedestal duration can make approach one without changing that FWHM.
Optical energy outside a time gate is a related observable that avoids assigning a pedestal underneath the main peak. For a specified gate containing that peak,In the rectangular example with equal to the main interval, . At and , this is , while . The difference is pedestal power inside the gate, which the outside-gate measurement does not label separately.
The analysis must also specify its temporal coverage and detector baseline subtraction. Subtracting actual weak light as though it were detector background changes the inferred laser pulse energy. A short detection time gate omits outlying light instead. Neither operation is justified solely by knowing the peak-to-pedestal contrast. The Sequoia technical sheet illustrates why temporal coverage and resolving power are separate instrument properties: it lists scan range, scan resolution and optical temporal resolution independently.[ref]
Sequoia temporal contrast measurement by Amplitude. January2024 sheet, PDFp2, Specifications