For a circular current loop, the Biot-Savart law is
where points from a current element to the field point. Choose the loop in the plane, with observation point . A parametrization consistent with positive axial magnetic field is
Then and
The transverse contributions cancel around the circle, leaving the on-axis magnetic field of a circular current loop
The right-hand rule fixes its direction; reversing the electric current reverses the magnetic field. At the centre this becomes , and far away it decays as , as expected for a magnetic dipole.
Model the uniformly wound air-core solenoid as coaxial circular turns with solenoid turn density . Put its ends at and an internal axial point at . By the superposition principle, integrating the on-axis magnetic field of a circular current loop gives
Since , this evaluates to the on-axis magnetic field of a finite solenoid:
The source's acute endpoint angles satisfy and . Hence
Although the paper calls this a “flux”, is magnetic flux density, measured in teslas. Magnetic flux is an surface integral , measured in webers, and cannot be assigned to a point. For example, two differently sized small disks at the same point have the same limiting but different magnetic fluxes, approximately times their normal areas. The displayed plus sign uses the internal-point angle convention shown in the source. Outside the coil, the integral expression still works, but one must retain signed axial projections rather than adding two acute-angle cosines.
At an end, , the on-axis magnetic field of a finite solenoid is
At its centre, , it is
The ratio is therefore
For a long solenoid, and . For a very short solenoid, the ratio tends to one, providing a separate check: its centre and end become nearly coincident compared with its radius.