A disorder affecting the respiratory system or its function. Airflow limitation, impaired gas exchange and disturbed control of breathing are different routes to respiratory disability.
Acute respiratory distress syndrome, or ARDS, is an acute form of respiratory failure in which widespread lung injury disrupts normal gas exchange. Fluid accumulates in the alveoli, and altered pulmonary surfactant function and tissue injury can impair expansion and reduce lung compliance. Hypoxemia describes the resulting deficiency of oxygen in arterial blood; it is an observation, not a complete explanation of its cause.[ref]
Acute Respiratory Distress Syndrome by NHLBI. What Is ARDS?: alveolar fluid, surfactant, oxygen transfer and stiffening
The alveolar-capillary barrier normally separates the air-containing region from circulating blood while permitting gas transfer. Injury changes both that interface and the mechanical behavior of the lung. A pressure required to inflate a damaged lung and an oxygen measurement therefore describe different parts of the problem.
One quantitative descriptor is the oxygenation ratio,where the numerator is arterial oxygen partial pressure and the denominator is inspired oxygen fraction, written as a fraction rather than a percentage. For stipulated , an inspired fraction gives , whereas gives . The same arterial measurement can therefore reflect different gas-exchange conditions. These examples do not establish a diagnosis or severity class without the other required clinical observations and measurement conditions.
A landmark primary trial tested how mechanical ventilation strategy affected outcomes in acute lung injury and ARDS. The ARDS Network randomized 861 patients to lower- versus traditional-volume strategies, also differing in plateau-pressure limits. Reported mortality was versus . The result showed that the mechanical conditions of supportive ventilation could affect outcomes, rather than treating delivered breath size as a neutral background variable.[ref]
Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome by the Acute Respiratory Distress Syndrome Network. Abstract, Methods and Results, 2000
These are historical trial observations, not a prescription for individual ventilator settings.Mechanistic explanations should keep oxygen transfer, compliance and patient outcomes distinct. A measurement that improves one physiological quantity does not by itself prove improvement in every other endpoint.
The oxygenation ratio, often called the P/F ratio, divides arterial oxygen partial pressure by inspired oxygen fraction:The denominator is a fraction, not a percentage number. Since it is dimensionless, the ratio retains the pressure units used in the numerator. An arterial blood gas analysis provides the partial-pressure measurement; its measurement target differs from oxygen saturation.[ref]
Arterial Blood Gas (ABG) Test by MedlinePlus. What is an arterial blood gas test?: oxygen partial pressure and saturation
For a constructed example, and give , approximately . Dividing by instead would give a result 100 times too small. Values expressed in kilopascals cannot be compared numerically with values expressed in millimeters of mercury without unit conversion.
The 2012 Berlin definition used this ratio in characterizing acute respiratory distress syndrome. That historical consensus also considered other syndrome criteria; the ratio alone does not establish the syndrome.[ref]
Acute respiratory distress syndrome: the Berlin Definition by the ARDS Definition Task Force. JAMA 307, 2526–2533: definition and performance evaluation
The inspired fraction and respiratory-support conditions must be recorded alongside the arterial measurement. Changing the denominator is not an experiment showing that arterial partial pressure must change proportionally.A first-order uncertainty propagation calculation shows why both measurements matter:If independent standard uncertainties are stipulated as and for the example above, each relative uncertainty is . Their quadratic combination gives a relative standard uncertainty , or about in the ratio. This example concerns measurement arithmetic, not a diagnostic threshold.
A disorder of the airways involving variable respiratory symptoms and variable airflow limitation. Airway inflammation and altered responsiveness connect episodic narrowing with changes that may persist between attacks.
Failure of the respiratory system to maintain adequate gas exchange for the body’s needs. Insufficient oxygenation and inadequate carbon dioxide elimination describe different physiological components.
Hypoxemia, also spelled hypoxaemia, is reduced oxygenation of arterial blood. Its characterization must identify what was measured: arterial oxygen partial pressure, oxygen saturation and arterial oxygen content are related quantities with different meanings. Hypoxia concerns inadequate oxygen availability to tissue, rather than simply naming an arterial measurement.
An arterial blood gas analysis measures the pressure of dissolved oxygen. Pulse oximetry instead estimates oxygen saturation optically; its output is not a direct partial-pressure measurement.[ref]
Arterial Blood Gas (ABG) Test by MedlinePlus. What is an arterial blood gas test?; Is there anything else I need to know?: measured partial pressure versus estimated saturation
This distinction explains why the observation and instrument should accompany a report of reduced oxygenation.A counting example separates saturation from oxygen amount. Suppose 100 available hemoglobin binding sites have 90 oxygen molecules bound: the occupied fraction is . Doubling the number of sites to 200 while keeping that fraction gives 180 bound molecules. The saturation is unchanged although the amount bound has doubled. This is a constructed binding-site count, not a conversion between oxygen saturation and partial pressure.
Likewise, oxygen carried per unit blood and blood delivered per unit time enter different factors. If is arterial oxygen content and is blood flow, then the transported amount per unit time is . Stipulated values and give ; halving halves that transport without changing . The example shows why one arterial oxygen measurement cannot by itself describe oxygen delivery to every tissue. It is not a diagnostic reference range or a treatment rule.
Ventilation insufficient to eliminate the carbon dioxide being produced. It can raise arterial carbon dioxide even when supplemental oxygen improves oxygenation, distinguishing ventilation from oxygen supply.