Bo Madsen (materials scientist) 2026-11-05
Bo Madsen studies the physical and mechanical behaviour of composite materials. His DTU profile relates experiments and analytical modelling to microstructure, volumetric composition and manufacturing conditions.[ref]
Bo Madsen profile at DTU. Personal profile, field of interest
He is also a named contributor to the shared glass- and carbon-fibre tensile dataset.[ref]Single fiber tensile test - Glass and Carbon fibers by Rajnish Kumar and others. Full contributor list
In 2024 he was first and corresponding author of an experimental vibroscope study with Rajnish Kumar and Hans Lilholt. The apparatus uses frequency measurements on a fibre under tension to infer its cross-sectional area. The paper compared simple, direct and iterative analysis procedures, and reported distributions of individual fibre areas rather than treating all strands as geometrically identical.[ref]
Vibroscope method for determination of cross-sectional area of glass and carbon fibres – Experiments and analyses by Bo Madsen and others. Institutional primary byline, corresponding-author mark and public abstract
This method addresses a practical difficulty in a single-fibre tensile test: the area needed to convert force into engineering stress may be difficult to determine from an image of one apparent diameter. Comparing independently inferred areas with the resulting stress-strain curves tests more than a force sensor alone. It also keeps geometric variation between material fibres separate from differences in the material's constitutive response. The work is a collaboration; the byline does not imply that Madsen alone performed every measurement.
Fibre (material) 2026-11-05
A material fibre is a long, slender physical strand: its length is large compared with its transverse dimensions. The geometry is shared by materials with different roles. Carbon fibres and glass fibres can reinforce a composite material, while an optical fibre guides light. The material's properties, the strand dimensions and the way strands are assembled all affect its response.
A single-fibre tensile test grips one strand, measures its axial force and extension over a specified gauge length, and uses its cross-sectional area to obtain stress and strain. A 2020 study used a semi-automated instrument to characterize glass fibres and carbon fibres through their stress-strain curves and inferred moduli.[ref]
Understanding the mechanical response of glass and carbon fibres: stress-strain analysis and modulus determination by Rajnish Kumar and others. Public primary abstract: single-fibre apparatus and modulus analysis
Its public dataset supplies individual tensile curves at several gauge lengths, summary sheets and calculations of test-setup machine compliance.[ref]Single fiber tensile test - Glass and Carbon fibers by Rajnish Kumar and others. Dataset description, gauge-length groups and compliance files
This matters because crosshead displacement can include deformation of the apparatus as well as extension of the material fibre; its slope alone need not give the specimen's Young's modulus.An original ideal model shows why making thinner strands changes some responses more strongly than others. Keep total material cross-sectional area , length and Young's modulus fixed. Compare one solid circular rod with identical circular fibres, each of radiusFor axial loading, grip every strand so that all undergo the same extension . Each supplies force , and adding the forces gives the axial stiffnessindependent of under these assumptions. This is the uniform-bar linear elasticity relation applied to parallel strands.
Now make a separate pure-bending comparison of an unbonded material-fibre bundle. Allow longitudinal sliding, neglect friction, and let each strand bend about its own neutral axis with the same curvature . A circular strand has second moment of area and filament bending modulus . Its bending moment is in the small-deformation model.[ref]
Stresses in Beams by David Roylance. Normal Stresses, equations3–6, pp.2–4: linear-elastic moment-curvature relation
Adding those moments gives the bending rigidity of an unbonded fibre bundle:Each material fibre has its own neutral axis, which is crucial to this calculation. Bonding strands together transfers shear stress and couples their axial deformation; the independent-strand sum then ceases to describe the assembly. In a reinforced composite material, that coupling is part of fibre-matrix load transfer.For chosen , and , both axial specimens have . At , each radius is approximately , and the independent-bending value is compared with for the solid rod. The parameters are stipulated for this model; counts material and excludes spaces between strands.
A useful mechanical comparison therefore records which material fibres are gripped, whether they can slide, their arrangement and the loading direction. Equal material quantity alone does not determine an assembly's stiffness, and small filament bending modulus does not imply small axial Young's modulus.
Hans Lilholt 2026-11-05
Hans Lilholt is a materials scientist whose DTU profile identifies research on composite materials, their preparation and their physical and mechanical properties.[ref]
Hans Lilholt profile at DTU. Personal profile, materials and mechanical-properties research
He is a named contributor to the glass- and carbon-fibre tensile dataset, alongside Rajnish Kumar, Bo Madsen and Lars Pilgaard Mikkelsen.[ref]Single fiber tensile test - Glass and Carbon fibers by Rajnish Kumar and others. Full contributor list
With Bo Madsen and Rajnish Kumar, he coauthored a 2024 experimental study of the vibroscope method for estimating fibre cross-sectional area from vibration under tension. It compared three analysis procedures and used tensile stress-strain curves in assessing the area estimates.[ref]
Vibroscope method for determination of cross-sectional area of glass and carbon fibres – Experiments and analyses by Bo Madsen and others. Primary byline and public abstract, frequency measurements and comparison of analysis procedures
An original calculation shows why this metrology affects a strength claim. At fixed measured force, inferring an area produces inferred engineering stressA chosen two-percent area underestimate therefore gives about a 2.04-percent stress overestimate. This is an illustrative calculation, not a new measurement from that study. The area measurement and its analysis belong alongside the reported tensile result; a force record alone does not determine material stress.
Lars Pilgaard Mikkelsen 2026-11-05
Lars Pilgaard Mikkelsen is a researcher in the mechanics of composite materials. His DTU profile describes combining the finite element method with experimental characterization of polymer matrix composites, particularly their mechanical fatigue and compression response.[ref]
Lars Pilgaard Mikkelsen profile at DTU. Personal profile, fields of interest
He coauthored the 2020 study of glass fibres and carbon fibres with Rajnish Kumar, Hans Lilholt and Bo Madsen. The study compared modulus determinations from single-strand stress-strain measurements.[ref]
Understanding the mechanical response of glass and carbon fibres: stress-strain analysis and modulus determination by Rajnish Kumar and others. Institutional byline and public abstract
The associated dataset identifies him by the full name Lars Pilgaard Mikkelsen and lists him as a contributor; it supplies individual tensile records and separate machine compliance calculations.[ref]Single fiber tensile test - Glass and Carbon fibers by Rajnish Kumar and others. Contributor list and description of tensile/compliance files
The measurement distinction is important for mechanics models: crosshead displacement can include movement of the test apparatus as well as specimen extension. A simulation supplied with a modulus inferred from that combined displacement can inherit an apparatus-dependent response. The single-fibre tensile test explains a numerical correction example; retaining both the individual records and the correction assumptions makes that inference inspectable. This is joint experimental work, and the cited records do not assign every instrument or analysis step to one coauthor.
Rajnish Kumar (materials scientist) 2026-11-05
Rajnish Kumar is a researcher in mechanical testing of composite materials. His institutional profile identifies him within DTU's composites manufacturing and testing group and gives ORCID 0000-0002-1243-9585, distinguishing this materials researcher from namesakes.[ref]
He was first and corresponding author of the 2020 glass- and carbon-fibre study with Lars Pilgaard Mikkelsen, Hans Lilholt and Bo Madsen. Their semi-automated single-fibre tensile test examined stress-strain-based modulus determinations. The public abstract reports an approximately strain-independent true-stress-based tangent modulus for the tested glass fibres, while the tested carbon fibres showed a tendency for that modulus to increase with strain.[ref]
Understanding the mechanical response of glass and carbon fibres: stress-strain analysis and modulus determination by Rajnish Kumar and others. Primary byline, corresponding-author mark and abstract, tangent-modulus findings
That distinction explains why one fitted Young's modulus need not summarize an entire stress-strain curve. A local slope and a slope fitted over a finite strain interval answer different questions; their definitions must accompany a comparison. The result concerns the tested specimens and the stated analysis, rather than every glass or carbon fibre. The associated dataset names Kumar as a contributor and preserves individual records and compliance calculations, allowing those measurement assumptions to be examined.[ref]
Single fiber tensile test - Glass and Carbon fibers by Rajnish Kumar and others. Contributor list and description of records and compliance files
Single-fibre tensile test 2026-11-05
A single-fibre tensile test pulls one material fibre between grips while measuring axial force and extension over a defined gauge length. A load cell supplies force information; a direct specimen-extension measurement or a corrected crosshead displacement supplies extension. With initial area and initial gauge length , the conventional engineering stress and engineering strain areThe initial proportional slope estimates Young's modulus; a changing local slope is a tangent modulus. The area and displacement conventions must accompany that result.
The glass- and carbon-fibre study by Rajnish Kumar, Lars Pilgaard Mikkelsen, Hans Lilholt and Bo Madsen used a semi-automated single-fibre machine and compared stress-strain-based modulus determinations.[ref]
Understanding the mechanical response of glass and carbon fibres: stress-strain analysis and modulus determination by Rajnish Kumar and others. Public primary abstract, apparatus and modulus analysis
Its dataset contains individual tensile curves, gauge-length groups and test-setup compliance calculations.[ref]Single fiber tensile test - Glass and Carbon fibers by Rajnish Kumar and others. Description, Data/Results files and Compliance spreadsheets
For an original ideal calculation, take a circular strand of diameter and . Its area is . A force increment produces measured crosshead travel . Suppose independently established machine compliance is , with no grip slip and the same deforming specimen length as . ThenUsing the uncorrected travel would instead give . These chosen increments represent a proportional segment, not measured dataset values or a complete uncertainty analysis.
Check grip slip, specimen alignment and the force zero before interpreting the slope. An irregular area cannot automatically be replaced by a circular area from one apparent diameter. A vibroscope offers another route to fibre-area estimation through vibration under tension.[ref]
Vibroscope method for determination of cross-sectional area of glass and carbon fibres – Experiments and analyses by Bo Madsen and others. Public abstract, area estimation from tensioned-fibre frequency measurements
Preserve the original force and displacement records so corrections and area assumptions remain inspectable.