Attosecond streaking uses a synchronized reference electric field to change a photoelectron's outgoing momentum. Scanning relative delay produces an energy-versus-delay distribution. A short emission interval samples only a small part of the reference cycle; a longer interval samples a range of kicks and can broaden or reshape the distribution.
For an explicit classical limit, use the electric dipole approximation and choose the magnetic vector potential along the detection axis with and . Neglect the residual ion's Coulomb force. An Electron released at with mechanical momentum obeys
Indeed, integrating from release to the end of the field gives the stated minus sign. The useful clock variable here is , rather than the instantaneous itself. If is nearly linear across a narrow emission window with temporal standard deviation , and initial momentum is sharp, then
This local mapping fails near a zero of , where first-order timing sensitivity vanishes. A real inversion must include the incident bandwidth, initial photoelectron distribution, collection angles and target–field response.
For an original dimensionless example in atomic units, choose , and . Then and , compared with initial kinetic energy . Reversing gives : the shifts are asymmetric because of the term. A measurement that keeps only the term linear in would miss in both cases.

Articles by others on the same topic (NaN)

There are currently no matching articles.