Derek Jones (magnetic resonance researcher) 2026-11-05
Derek Jones is a physicist at Cardiff University whose research develops quantitative magnetic resonance imaging, especially diffusion tensor imaging. He trained in physics at Nottingham, medical physics at Leeds and completed a Leicester doctorate on diffusion tensor imaging. His work asks how acquisition design changes what can be inferred from a measured signal.[ref]
Derek Jones profile at Cardiff University. Overview, Research and Biography: research focus and1993/1995/1998 education
Derek Jones, from his labeled Cardiff University staff-profile portrait
. Jones investigated how diffusion MRI gradient sampling affects the measurement uncertainty of inferred diffusion tensors. In 2004, Jones used Monte Carlo simulations to compare sampling schemes at a diffusion weighting b-value of , tracking tensor orientation, trace and fractional anisotropy. It showed why a minimal set of directions need not give robust estimates; its numerical findings belong to the tested models and noise conditions.[ref]
The effect of gradient sampling schemes on measures derived from diffusion tensor MRI: A Monte Carlo study by Derek K. Jones. Original abstract: controlled b-value, tensor-derived outcomes and comparison of angular sampling schemes
An earlier conference report made the comparison with a fixed observation budget: one baseline and 60 diffusion-weighted observations. Six unique orientations repeated 10 times and 30 orientations repeated twice therefore used the same number of diffusion-weighted observations. Varying angular coverage while controlling that budget separates a direction-design question from simply acquiring more data.[ref]
The Effect of Gradient Sampling Scheme on Estimates of Fiber Orientation: Implications for Fiber Tractography by D. K. Jones. Methods and Table1:61 total rows, unique orientations and repetition counts
A noise-free calculation illustrates diffusion tensor identifiability. With separately known baseline , fixed and a unit direction , the Gaussian diffusion tensor model givesThe symmetric matrix has six independent coefficients. Its quadratic form produces a row in a linear least squares design. Directions give six observations but only matrix rank three: opposite directions repeat a row and the off-diagonal coefficients remain undetermined.
Adding the normalized mixed directions , and to the three positive coordinate axes instead gives matrix rank six. For example,This establishes uniqueness in the stated noise-free model. It does not establish small measurement uncertainty or an optimal experimental design.
Original noise-free diffusion-tensor design matrices: six antipodal directions give rank three, while axes plus three mixed directions give rank six
. Details. Jones also interviewed John E. Tanner about the physical origins of pulsed field gradient NMR. The interview preserved concrete details of the apparatus, including Tanner's carefully spaced mica stack and the practical difficulties of rapidly switching magnetic field gradients.[ref]
John Tanner, the return to Germelshausen, and the work that nearly never happened by Derek Jones. pp.6–7: restricted-diffusion apparatus and switching problems
Diffusion MRI gradient sampling 2026-11-05
Diffusion MRI gradient sampling is the choice of magnetic field gradient directions, strengths and repetitions used to acquire diffusion magnetic resonance imaging measurements. Under a Gaussian diffusion tensor model, different directions probe different values of a quadratic form. Acquiring many measurements in an uninformative set of directions cannot determine every tensor coefficient.
For a unit gradient direction , a separately measured matched baseline and fixed positive diffusion weighting b-value , the ideal signal model isThe symmetric matrix has six independent coefficients. Opposite directions and give the same model prediction. Thus counting orientations without considering their independent information can overstate diffusion tensor identifiability.
A 2003 Monte Carlo simulation study controlled the observation budget: one baseline plus60 diffusion-weighted observations. Six distinct orientations repeated ten times and30 distinct orientations repeated twice each use60 diffusion-weighted observations. The comparison asks how angular coverage and repetition affect estimated orientation, rather than simply comparing a longer acquisition with a shorter one.[ref]
The Effect of Gradient Sampling Scheme on Estimates of Fiber Orientation: Implications for Fiber Tractography by D. K. Jones. Methods and Table1: observation budget, directions and repetitions
The subsequent 2004 study compared direction schemes through estimated orientation, trace and fractional anisotropy at . These are distinct outputs of the same tensor fit. An acquisition suited to one readout need not minimize uncertainty in another.[ref]
The effect of gradient sampling schemes on measures derived from diffusion tensor MRI: A Monte Carlo study by Derek K. Jones. Primary Abstract: Monte Carlo design and tensor-derived measurements
An original design comparison separates two questions. Repeating the three coordinate axes may reduce random variation in their measured attenuations, but it adds no equations for the three off-diagonal tensor entries. Adding suitable mixed directions can supply those equations. Full matrix rank establishes uniqueness in the ideal model; practical measurement uncertainty, motion and model mismatch still require assessment.