Right ventricle 2026-11-05
The right ventricle is the heart chamber receiving blood from the right atrium through the tricuspid valve and ejecting it through the pulmonary valve into the pulmonary trunk.[ref]
Anatomy and Physiology 2e by J. Gordon Betts and others. Section 19.1, Chambers and Circulation through the Heart
Its output enters the pulmonary circulation rather than passing directly into the aorta.The chamber's volume changes through the cardiac cycle. Define stroke volume as end-diastolic minus end-systolic volume:The second ratio is the right ventricular ejection fraction. In an original example with and , stroke volume is and ejection fraction . At beats per minute, multiplying stroke volume by rate gives .
That last conversion represents net forward output only under its stated assumptions. Significant backward or alternate flow can separate chamber-volume displacement from the amount delivered onward. Nor does an ejection fraction alone provide the chamber's absolute output: chambers with different initial volumes can share the same fraction.
In a steady serial-circulation model without shunts or sustained storage, right- and left-sided net outputs must balance. A persistent difference would accumulate blood somewhere in the system. This conservation statement does not require the two ventricles to generate equal pressure or perform identical mechanical work. Anatomy, volume displacement, forward flow and pressure are distinct but connected observations.
Second heart field Created 2026-10-20 Updated 2026-11-05
A population of cardiac progenitors that contributes cells to the developing heart after initial heart-tube formation. Retaining a proliferative reservoir allows progressive addition of differentiated myocardium.
Serkan Ünlü 2026-11-05
Serkan Ünlü investigates cardiac imaging and the dependence of measured heart function on image acquisition. His official institutional profile identifies cardiology as his unit and lists cardiac and cardiovascular research areas.[ref]
Serkan Ünlü academic profile at Gazi University. General Information, institutional unit and research areas
Ünlü is first author of a primary study testing cardiac image foreshortening in echocardiography. The investigators imaged 72 participants using a GE Vivid E9 system and deliberately collected altered apical views from a window one rib-space above the optimal position. They compared ejection fraction and longitudinal deformation measurements using two analysis systems.[ref]
Impact of apical foreshortening on deformation measurements: a report from the EACVI-ASE Strain Standardization Task Force by Serkan Ünlü and others. Byline; Abstract, Methods and results
This is an experimental acquisition comparison: the view changes while the patient's chamber is not assumed to have become anatomically shorter.An original geometric example shows why a constant scale error and a phase-dependent distortion have different consequences. Let a modeled chamber length change from to cm. Its fractional shortening isMultiplying both lengths by 0.9 leaves the ratio unchanged. If instead the measured lengths become 9 and 7 cm because the same 1 cm terminal segment is missed in each phase, the apparent fractional shortening is . Neither model is a complete echocardiography reconstruction; they demonstrate why the error mechanism matters even in a normalized measurement.
The primary study found that deliberately foreshortened views changed measured deformation, with the effect differing by myocardial layer and analysis system.[ref]
Impact of apical foreshortening on deformation measurements: a report from the EACVI-ASE Strain Standardization Task Force by Serkan Ünlü and others. Abstract, Results and Conclusion
Ünlü's documented contribution is to test that dependence experimentally. Repeatable software output does not establish that the acquired image represents the intended anatomical view. Sinoatrial node 2026-11-05
The sinoatrial node is a group of specialized cardiac cells that normally initiates the electrical rhythm of the heart. Its pacemaker cells gradually undergo depolarization between action potentials instead of remaining at a stable resting voltage. Their activity spreads into surrounding atrial cardiac muscle through electrical coupling. [ref]
Anatomy and Physiology 2e by J. Gordon Betts and others. Section 19.2, Autorhythmicity of Cardiac Cells and the Sinoatrial Node
The rhythm can arise without a separate motor nerve triggering every beat. Autonomic inputs modulate its rate, while conduction through other cardiac structures organizes the order of activation. Pacemaker activity, propagation and mechanical contraction are therefore different stages: recording the first does not by itself prove that every later stage proceeds normally.
Sinus rhythm Created 2026-10-31 Updated 2026-11-05
A cardiac rhythm initiated by the sinoatrial node and propagated through the usual activation pathway. Sinus rhythm specifies the origin and pattern of activation, not a guarantee that every aspect of heart function is normal.
Todd Heallen Created 2026-10-20 Updated 2026-11-05
Coauthor of research on Hippo signaling and heart size. The study investigated inhibition of Wnt signaling and cardiomyocyte proliferation, connecting pathway interactions with control of organ growth.[ref]
Umbilical artery Created 2026-10-31 Updated 2026-11-05
Vein Created 2026-10-31 Updated 2026-11-05
Venous pole of the heart Created 2026-10-20 Updated 2026-11-05
Venous return Created 2026-10-31 Updated 2026-11-05
Venous return is blood flow returning toward the heart. Over a stable interval it balances cardiac output, but transient storage changes can occur. Venous pressures, compliance, surrounding muscle activity and breathing contribute to the return pathway.
William A. Mandarino 2026-11-05
William A. Mandarino is a named coauthor of the 1994 study estimating ventricular compliance from automated echocardiography and pressure measurements in an isolated-heart preparation. The full publisher byline establishes this identity and the shared contribution; it does not assign a separate experimental task to each coauthor.[ref]
The method pairs image-derived ventricular area with simultaneously acquired pressure, using a balloon volume as an experimental reference. A micromanometer's pressure zero and the chamber's external pressure are different inputs to interpreting that relation.
For an original measurement model, suppose the recorded pressure is , with constant offset . Then : a fixed zero offset moves a curve vertically without changing its local derivative. By contrast, a gain error givesIf , inferred ventricular compliance is about 9.09% low even though the curve retains the same qualitative shape. These stipulated errors explain why measurement calibration matters; they are not errors reported for Mandarino's apparatus.
The study's repeated paired measurements therefore concern a quantitative mapping, not just acquisition of a recognizable heart image. Its experimental results support the tested preparation, while the abstract explicitly reserves validation in clinical use.[ref]
Estimation of left ventricular compliance using on-line echocardiographic automated border detection and pressure data by John Gorcsan III and others. Abstract, simultaneous acquisition, repeated volume runs and stated limitation