Let denote isotropic permeability of a porous medium, the fluid dynamic viscosity, the reference fluid mass density, its volumetric thermal-expansion coefficient and gravitational acceleration. The Boussinesq approximation uses only in the gravitational force. With upward coordinate , hydraulic pressure and Darcy flux , the equations are
where is the perturbation to the conductive temperature. To keep porous heat-capacity conventions explicit, let be effective heat capacity per bulk volume, the liquid volumetric heat capacity, effective thermal conductivity, , and . The thermal equation is . If the usual unit-capacity convention is adopted, and is the thermal diffusivity. Thresholds below do not depend on ; it only changes temporal rates.
For a conductive state with upward temperature decrease , linearization gives
where . The second equation follows by taking the divergence of Darcy law to eliminate and then differentiating its vertical component. It is important that the Laplacian on its right is horizontal.
In the horizontal layer, both boundary planes prescribe the temperature and are impermeable, so at . Use a normal mode proportional to , with horizontal wavenumber , . Writing , the momentum relation gives , and the thermal relation gives
A neutral mode therefore requires . Since , the smallest value is , attained at and . This derives the onset of convection in a horizontal Darcy layer rather than simply importing its critical number. Thus
Every small disturbance decays for ; at equality the critical roll is neutral. Strict decay has this threshold as a supremum, not an attained maximum. The first roll wavelength is , compatible with the very large horizontal extent. Cooling from above gives the opposite, stable buoyancy feedback.
For the tall square column, define as its side length and as its height. The insulated vertical walls impose , while impermeability imposes zero normal Darcy flux. Away from the remote ends, a nearly height-independent mode has hydrostatic pressure adjustment and , with zero cross-sectional mean. The transverse temperature modes are
where but is excluded: a closed column cannot support a net vertical discharge. Its horizontally uniform density perturbation is balanced by pressure, rather than driving overturning. The rate of a nonconstant mode is
The smallest allowed eigenvalue is , so the insulated square-column Darcy convection onset is
Again strict decay requires . This is the leading long-column result. End conditions that maintain the basic gradient require the vertical velocity to turn around near the ends and give small finite-height corrections; their exact coefficient cannot be inferred from insulation of the vertical walls alone. For a separated vertical mode of small wavenumber , the neutral expression is , which tends to the displayed value as .
Just above threshold, warm fluid rises along one side and colder fluid sinks along the opposite side, with horizontal return flow at the top and bottom. The two lowest modes, proportional to and , have the same threshold. A square therefore admits either orientation or a superposition, including diagonal overturning. Linear theory predicts the weak columnar circulation and its degeneracy; it does not select a unique nonlinear planform.