Isidor Rabi developed molecular-beam magnetic resonance for measuring nuclear magnetic moments. Two magnetic field gradient regions focus a selected beam onto a detector, while an intervening uniform magnetic field sets the resonance frequency. An oscillating transverse magnetic field drives transitions between magnetic quantum states. On resonance, the changed states no longer follow the focused path, reducing the detected intensity. Measuring the Larmor frequency in a known magnetic field thereby replaces a small static deflection with a more precise frequency comparison.[ref]
Identity source: www.nobelprize.org/prizes/physics/1944/rabi/facts/
Portrait of Isidor Rabi
. Nobel Foundation; individual photographer not identified. Public domain in Sweden under the File’s Swedish-photograph rule; United States justification not verified. Source usage terms, via Wikimedia Commons. Source. Jerrold R. Zacharias Created 2026-10-18 Updated 2026-11-05
An experimental atomic physicist who coauthored the molecular-beam method for measuring nuclear magnetic moments. Instead of determining a moment solely from a beam's static deflection, the experiment found the Larmor frequency in a known magnetic field. A resonance-induced loss of focused beam intensity made this frequency measurable with high precision.[ref]
The Molecular Beam Resonance Method for Measuring Nuclear Magnetic Moments by Isidor Isaac Rabi and others. p. 526: frequency measurement and loss of beam focusing
Transverse nuclear magnetic resonance measures absorption from a radio-frequency magnetic field perpendicular to the static field. In the A phase, the resonance moved above the Larmor frequency; in the B phase it returned to that frequency despite the changed state. Anthony James Leggett connected the shift to collective spin-orbit structure. A predicted longitudinal resonance, driven parallel to the static field, supplied a further B-phase test.[ref]
Nobel Lecture: Superfluid 3He: the early days as seen by a theorist by Anthony James Leggett. pp.1002–1003 and1009, transverse geometry and longitudinal test
The helium-3 superfluid discovery experiment establishes why a new phase was inferred; comparing response channels then tests its internal structure. An unchanged peak in one geometry cannot, by itself, establish that nothing ordered.
Nuclear magneton Created 2026-10-18 Updated 2026-11-05
The nuclear magneton is the unit of magnetic momentwhere is the proton mass. For a nuclear spin operator , the nuclear magnetic moment is . Consequently its gyromagnetic ratio is , and its Larmor frequency in a uniform magnetic field of magnitude is . The nuclear magneton is smaller than the Bohr magneton by the electron-to-proton mass ratio.
Optical magnetometry 2026-11-05
Optical magnetometry infers a magnetic field from the response of optically prepared and observed atomic spins. In a typical vapor-cell apparatus, resonant pump light polarizes alkali atoms; a field makes that polarization precess at a Larmor frequency . Probe-light absorption or rotation converts the spin evolution into an optical signal.[ref]
Optical Magnetometry by Dmitry Budker and Michael Romalis. Principles of optical magnetometry and atomic-vapor implementations
A motivating experiment uses a sealed vapor cell, pump and probe beams, photodetection, magnetic shielding and coils producing a known test field. Applying an oscillating field and sweeping its frequency reveals a resonance near . Its shift when the coil current changes calibrates the field response, while its width reflects spin relaxation. If a sensor has a calibrated gyromagnetic ratio , a 70 Hz resonance corresponds to 10 nT in this simple model. This numerical example illustrates conversion of frequency to field; actual calibration must control light shifts, field gradients and relaxation. Optical readout detects the spin response, not a direct image of the magnetic field.
Past exam of the advanced quantum physics course of the University of Cambridge 2017 1 a Solution 2026-10-18
Use the isolated nuclear spin Zeeman effect implied by the supplied nuclear magnetic moment, with hyperfine structure neglected. The proton gyromagnetic ratio isThe two spin levels are separated by . Resonant nuclear magnetic resonance therefore requires the Larmor frequency
The duration is a Rabi pi pulse: in a frame rotating with the resonant transverse magnetic field, the spin must rotate through . If denotes the magnitude of a circularly rotating field with the correct sense of rotation, the Rabi angular frequency is . The shortest pulse is then
There is an amplitude convention to specify. If the applied transverse magnetic field is instead the linearly oscillating , its resonant circular component has magnitude . The rotating-wave approximation gives and henceThe wording does not specify this polarization convention, so the two pulse durations should be distinguished. Odd multiples of either shortest Rabi pi pulse also invert the spin within the corresponding ideal model.
Stimulated echo 2026-11-05
A stimulated echo is a delayed nuclear magnetic resonance signal produced by a sequence that stores part of a dephased magnetization pattern along the static magnetic field and later converts it back into detectable transverse magnetization. In a common ideal sequence, three pulses are applied at times , and . The selected stimulated echo appears a further after the third pulse, at .[ref]
The first interval lets spins with different Larmor frequencies accumulate different phases. The second pulse converts part of that frequency-dependent pattern into longitudinal magnetization. During the storage interval this component does not precess as transverse magnetization does. The third pulse returns part of the pattern to the transverse plane, where the appropriate contribution rephases. Storage retains a frequency-dependent population pattern, not a continuously rotating transverse vector.[ref]
For an original ideal calculation, hold fixed and neglect diffusion, pulse errors and exchange. If is the spin-lattice relaxation time, the selected echo contribution obeysA storage interval therefore halves that contribution. The two transverse intervals still incur transverse relaxation; longitudinal storage does not undo every source of signal loss.
This distinction is useful for diffusion measurements when a longer observation interval is wanted without keeping the relevant pattern transverse throughout. A 1989 experiment used pulsed-gradient stimulated echo sequences to reduce particular background-gradient effects in heterogeneous samples. It tested specified pulse arrangements, rather than establishing that every stimulated echo removes every gradient error.[ref]
Pulsed field gradient stimulated echo methods for improved NMR diffusion measurements in heterogeneous systems by R. M. Cotts and others. Abstract: pulsed-gradient sequences, cross-term cancellation conditions and experimental tests