Apply the steady-flow energy balance to an entire liquefaction apparatus, allowing a warm gas outlet and a separate cold liquid outlet. With incoming heat per unit feed mass, no shaft work, and negligible changes in bulk kinetic energy and gravitational potential energy, conservation of mass and conservation of energy give . Solving this equation gives the displayed liquid mass fraction.
The two outlet streams need not share a temperature. For example, a counterflow heat exchanger can warm returning gas before it crosses the overall control volume boundary, while collected liquid leaves at the cold end. When the outlet temperatures differ, includes sensible heating as well as phase change; it is not simply a latent heat. A colder two-phase separator nested inside the apparatus has its own boundary states and a different local enthalpy balance.