For steady flow through a fixed control volume with one inlet and one outlet, the first law of thermodynamics and conservation of mass give
Here is the mass flow rate, incoming heat per unit time, outgoing non-flow work per unit time, the flow speed, elevation and gravitational acceleration. The specific enthalpy includes both the transported internal energy per unit mass and the pressure work needed to push volume through the boundary; is mass density. The inlet supplies that pressure work, while the outlet consumes it to displace the downstream fluid.[ref]
For an insulated stationary throttle, require negligible heat transfer, no shaft or other non-flow work, and negligible changes in bulk kinetic energy and gravitational potential energy. Then . With unchanged composition this is also equality of molar enthalpy. The upstream and downstream states must admit equilibrium pressure, temperature and property values, although the constriction itself is irreversible and can be far from thermodynamic equilibrium. Start-up storage of energy in the walls and fluid, heat leakage, or a large outlet speed invalidates the reduced balance. A nozzle can convert specific enthalpy into bulk kinetic energy even when it is insulated.
The same accounting for a fixed transported amount is , hence . This explains why dropping the two pressure work terms would give the wrong conserved quantity.[ref]