MALDI, short for matrix-assisted laser desorption/ionization, is an ionization method for mass spectrometry. The sample is prepared with a MALDI matrix that absorbs the incident laser light and helps release sample molecules into the gas phase as ions. The MALDI matrix is a chemical preparation component; it is distinct from the mass analyzer that subsequently separates the ions. Combining MALDI with time-of-flight mass spectrometry gives MALDI-TOF. The measured mass-to-charge ratio characterizes the resulting ion, rather than directly reporting the mass of an uncharged molecule.
For an illustrative molecule of nominal mass atomic mass units, adding one proton gives a singly charged ion with nominal mass-to-charge ratio , whereas adding two protons gives approximately . These are simplified assignments that neglect exact mass defects. A second peak therefore need not mean a second molecular species: charge states, isotopes and attached ions also affect a mass spectrum.
In the 1997 tissue-imaging experiment, a MALDI matrix coated a tissue section or its blotted imprint, and an ordered array of mass spectra supplied a spatial map for a selected mass-to-charge ratio. The investigators mapped insulin in rat pancreas and peptides in rat pituitary. This connects the ion source to mass spectrometry imaging: sample position supplies the image coordinates, while the mass spectrum supplies chemical discrimination. A bright pixel alone does not establish an absolute molecular concentration.[ref]
A MALDI matrix is material combined with an analyte to assist its release and ionization during MALDI. In ultraviolet MALDI, the MALDI matrix absorbs light at the laser wavelength, coupling the pulse to a sample that need not absorb efficiently on its own. Its chemical and physical properties influence the resulting mass spectrum.
An early experiment compared amino acids at different laser wavelengths. In a mixture of alanine and tryptophan irradiated at , an alanine molecular-ion signal appeared at about one tenth of the irradiance required for alanine alone. Absorbing tryptophan therefore supplied a concrete matrix-assisted effect; the useful observation was the changed ion-production threshold.[ref]
An idealized optical model illustrates why absorption matters without predicting ion yield. If a uniform layer has absorption coefficient and thickness , the Beer-Lambert law gives absorbed fraction , ignoring reflection and scattering. Optical depths and give approximately and . These are absorbed-light fractions, not the fractions of analyte molecules that become detected ions; chemistry and subsequent transport still intervene.
The MALDI matrix can also affect spatial interpretation. A tissue-imaging study at sampling found matrix-crystal clusters larger than the sampling scale; their distribution contributed granular structure to the ion image.[ref] Matrix preparation is consequently part of the measurement, not an invisible supporting surface. Mass spectrometry image normalization may reduce some common intensity variation, but it cannot make every matrix-dependent response an absolute concentration measurement.