2001 attosecond pulse-train experiment 2026-10-18
Pierre Agostini's experiment illuminated an argon jet with an annular beam. A pinhole removed the annulus; a tungsten-coated mirror relayed harmonics and weak central reference into another argon jet. A magnetic-bottle electron spectrometer used time of flight and microchannel plate detectors. Glass plates varied delay. Reference-on sidebands contrasted with reference-off peaks. Atomic-phase-corrected reconstruction yielded -attosecond bursts.[ref]
Observation of a Train of Attosecond Pulses from High Harmonic Generation by P. M. Paul and others. pp.1690–1691, Figs.1–4 and Table 1
The two-path attosecond phase reconstruction explains the control's purpose: adding the reference opens an interference channel. Its fitted oscillation tests phase relationships under the weak-field and atomic-response model. It does not independently reveal every target phase or an arbitrary nonperiodic optical pulse.
Fermionic atom antibunching 2026-10-14
The 2007 paper Comparison of the Hanbury Brown-Twiss effect for bosons and fermions by T. Jeltes and others compares polarized helium-3 fermions with helium-4 bosons. The chemical atoms occupy a metastable atomic level. Switching off magnetic trapping of neutral atoms releases them onto a microchannel plate detector with a delay-line anode, 63 cm below. Position and arrival-time readouts give three-dimensional pair separations by time-of-flight atom detection. About 1000 clouds per isotope supply histograms; normalization removes the broad cloud shape.
The pair detection correlation dips below one for helium-3 and rises above one for helium-4. The same apparatus, matched temperatures near , nearly identical trapping potentials, negligible interactions, and magnetic field gradient checks of spin polarization support an exchange-statistics interpretation. Finite detector resolution suppresses contrast; trap switch-off and resolution uncertainties limit quantitative agreement. A diverging laser lens deepens the dip, but its aberrations preclude a precise lens-model test. This detects exchange correlations, rather than measuring occupation of one selected spin orbital.[ref]
Comparison of the Hanbury Brown-Twiss effect for bosons and fermions by T. Jeltes and others. pp. 3–7, Methods, Figs. 1–3; supplementary pp. 14–16
A molecular nitrogen experiment used a pulsed nozzle and two skimmers. A tube raised the rotational temperature. Opposed vacuum-ultraviolet laser pulses excited selected molecular levels and, about later, selectively ionized excited nitrogen fragments. A microchannel plate detector, phosphor screen and camera recorded radii.[ref]
Accurate measurements of the bond dissociation energies of 14N2, 14N15N and 15N2 by Liya Lu and others. Lu, Jiang and Gao, §2, printed manuscript pp. 2–3: nozzle, tube, pump/probe and imaging readout
The measured squared radii were fitted against molecular excitation energies, referenced to the parent ground state:The intercept at zero radius gave the excited-product threshold; the fitted slope absorbed the detector scale. A wavemeter monitored the excitation source; scanning the probe covered the recoil Doppler shift. Subtracting the atomic excitation energies converted the intercept to ground-product .[ref]
Accurate measurements of the bond dissociation energies of 14N2, 14N15N and 15N2 by Liya Lu and others. §1: image-radius equation; §2: wavemeter and probe scan; §3 and Figure 4: fits; §4: atomic excitation correction
An apertured grounded plate and detector timing rejected faster competing channels. Selecting fragment electronic states distinguished nearby thresholds. Agreement of across isotopes after zero-point energy correction tested consistency. The method still requires correctly assigned levels, adequate near-threshold signal and stable imaging; a signal drop alone can reflect another channel or a barrier.[ref]
Accurate measurements of the bond dissociation energies of 14N2, 14N15N and 15N2 by Liya Lu and others. §2: shielding plate and timing; §3: state-selected channels; §4 and Table 2: isotope consistency and limitations
This measurement determines a state-resolved ground-state dissociation energy. Obtaining a finite-temperature bond-dissociation enthalpy requires the thermal increments above; obtaining a bond potential-well depth requires the zero-point energy correction. The three quantities describe different starting conditions for the same specified separation.
Surface ionization detector Created 2026-10-14 Updated 2026-11-05
A surface ionization detector detects a neutral atomic beam by converting incident chemical atoms into ions on a hot surface. For suitable alkali metals, a heated tungsten surface can favor loss of an electron: the competing surface work function and atomic ionization energy make the efficiency strongly dependent on species, surface condition and temperature. An electric field then collects the resulting ions, producing an electric current or a count after amplification. A response therefore requires an efficiency measurement calibration; it is not automatically equal to the incident particle flux.
A 2002 imaging experiment used a tungsten-coated heated ribbon followed by a microchannel plate detector and a phosphor screen. It recorded where the arriving neutral chemical atoms struck, rather than just their total rate. The reported approximately spatial resolution and roughly detection efficiency belong to that apparatus and its conditions, rather than to every surface ionization detector.[ref]
Time-of-flight atom detection Created 2026-10-14 Updated 2026-11-05
Time-of-flight atom detection measures particles after releasing a trapped atomic cloud and allowing it to expand for a known time. For ballistic motion, , so after accounting for gravity the late position largely reflects the initial momentum when the initial cloud size is sufficiently small.
A position- and time-resolving detector can record individual arrivals and form spatial pair correlations. In fermionic atom antibunching, such correlations probe suppression of nearby detection pairs for the prepared state. Finite source size, interactions during early expansion, detector resolution and detection efficiency limit a literal initial-momentum interpretation; expansion is part of the experimental model, not merely a delay before measurement. A microchannel plate detector is one implementation for suitable metastable atoms.