Voltmeter loading 2026-10-14
Voltmeter loading is the change in an electric potential difference caused by the electric current drawn by the measuring voltmeter.
For a loaded voltage divider in steady direct current, a voltmeter connected across the lower resistor places its finite input electrical resistance in parallel with the lower arm's electrical resistance and any intended electrical load of electrical resistance . With positive, fixed electrical resistances, an upper resistor of electrical resistance , and an ideal voltage source supplying electric potential difference , Kirchhoff's current law and Ohm's law give
Here is the connected circuit's electric potential difference across the voltmeter; omit if there is no intended electrical load. The parallel connection and need for large input electrical resistance are standard voltmeter operating principles.[ref]
Voltmeter loading is a bias relative to the target electrical circuit with the voltmeter absent and any intended electrical load still present. Voltage divider loading error instead compares the attached-load output with the wholly unloaded output. An accurate readout of , supported by measurement calibration, can still differ from either target: calibration accuracy concerns the indication of the connected electric potential difference, whereas voltmeter loading changes that electric potential difference itself.
Wheatstone bridge balance 2026-10-14
First disconnect the detector. Each side is a voltage divider. Ohm's law and Kirchhoff's voltage law give the open-circuit intermediate electric potentials and their difference:
Setting this difference to zero and cross-multiplying gives
The balance compares ratios, not necessarily equal arm values or equal branch electric currents. At balance the detector carries no electric current, so Kirchhoff's current law again makes the electric current constant along each two-arm path.[ref]
For a worked null measurement, suppose and , and the detector null occurs at adjustable . Then
For , both intermediate electric potentials are . The left branch carries and the right branch : the zero detector reading does not mean that the unknown carries no electric current. These are stipulated ideal values illustrating the calculation, not experimental observations.