Let be the magnitude of each transferred electric charge, and let arrivals form a Homogeneous Poisson process of rate . Extend the stream over past and future times when considering stationary filtering. For Electrons, , the elementary charge. Choose the positive electric current direction to follow these transfers, so is its mean magnitude. If counts arrivals in a gate of duration , then
The gate's transferred electric charge is , and its average electric current is . Scaling the expected value and variance gives
More arrivals increase the absolute fluctuation but decrease its size relative to the mean. For an original count example with , the mean count and its variance are both , the standard deviation is , and the relative standard deviation is . The probability of no transfer is ; the probability of four is . A constant arrival rate does not prescribe four arrivals in every gate.
These are fluctuations of a time average, not the variance of an ideal instantaneous electric current. A model of point transfers has arbitrarily sharp impulses; it acquires a finite measured variance only after specifying a gate or linear filter. Actual collection pulses have finite duration and electrical circuits have finite response times.