Systematic error Created 2026-10-14 Updated 2026-11-05
A systematic error is a component of measurement error that remains constant or changes predictably when measurements are repeated under specified conditions. A ruler with an incorrect scale, a thermometer with a measurement zero offset, and an unaccounted instrumental drift can all produce such effects. Closely agreeing readings can therefore have poor measurement accuracy: repetition tests their scatter, not the correctness of the shared reference.
An estimated systematic error should be corrected when possible, with the correction's measurement uncertainty included in the measurement uncertainty budget. Suppose a balance reads and a reference gives an estimate of its offset. The corrected result is ; uncertainty in remains even if the same unknown offset affected every weighing. Changing the reference, using a blank, or testing systematic-error cancellation by reversal can reveal effects that a long sequence of identical readings misses. The Type A evaluation of uncertainty and Type B evaluation of uncertainty distinction concerns how uncertainty is evaluated, so neither label is synonymous with systematic error.[ref]
Tare mass 2026-11-05
Tare mass is the specified container or packaging mass excluded when reporting net mass. It is also called tare weight in weighing terminology. The intended boundary matters: a jar alone and that jar with its lid have different tare masses. A tare device adjusts a weighing scale's indication with a load present, whereas a zero-setting device establishes zero with the load receptor unloaded.[ref]
A simple demonstration separates the reading from the physical load. Choose an empty container of mass and an ideal weighing scale that initially reads zero. After the container is placed on the load receptor, operate the tare device. Its displayed value becomes zero while the container's mass remains . In a uniform gravitational field with chosen magnitude , its gravitational weight is stillThe supporting force remains present after the display adjustment.
In an ideal unit-gain measurement model, the tared indication for a complete load of mass is . Adding of contents gives gross mass and indication . Removing the complete load while retaining that reference gives indication . The negative indication expresses the difference from the stored reference; the removed container still has positive mass.
A preset tare device instead uses an introduced preset tare value, which can be recalled or entered without weighing each individual empty container.[ref] For the same chosen load, using a preset of gives calculated net mass : the contents are overestimated by 20 g. A persistently low preset produces a systematic error even with otherwise exact readings.
Composite tare mass includes several excluded components, such as all the jars and an outer crate. The gross mass example shows how to account for these components once each. The symbol here denotes a mass; the terminology's use of the word weight does not change the quantity's unit from a kilogram to a unit of force.
Type A evaluation of uncertainty 2026-11-05
A Type A evaluation of uncertainty obtains an uncertainty component through statistical analysis of observations. For independent repeated readings with sample standard deviation , the estimated standard uncertainty of their mean is .
Independence and stability matter: serially correlated readings do not generally provide independent pieces of information. Type A and Type B evaluation of uncertainty classify how components are assessed, rather than separating random measurement errors from systematic error.[ref]
Zero-lift drag coefficient 2026-11-05
The zero-lift drag coefficient is the drag coefficient at for a stated configuration and flow condition. It is not necessarily the drag at zero angle of attack: a cambered airfoil can have a nonzero zero-lift angle of attack. In a simple parabolic drag polar, , the lift-dependent term vanishes there.[ref]
Induced Drag Coefficient by NASA Glenn Research Center. Total drag decomposition,
The zero-lift drag coefficient also need not be the smallest drag coefficient on a general polar. An original shifted parabolic drag polar,has minimum at , while . Confusing the intercept with the minimum loses the shift caused by the particular aerodynamic configuration.
A measurement should locate the state where the measured lift crosses zero, then evaluate or interpolate drag at that state using compatible references. Zero readings can be affected by balance tare and systematic error. Measurements at several nearby angles of attack distinguish a crossing from one apparently small reading.
For a complete aircraft, the coefficient can include skin-friction, pressure and component-interaction effects under the selected decomposition. A finite-wing term proportional to can vanish at zero lift without making those other sources of drag vanish. Holding constant while changing speed is itself an approximation if the Reynolds number, Mach number or flow state changes.