Topics (384k) Articles (398k) Users (410) Discussions (242) Comments (383) Files (13k) New article
The inner ear contains fluid-filled sensory structures for hearing and balance. In the cochlea, motion transmitted from the middle ear creates a traveling disturbance along the basilar membrane. Movement of sensory hair cells bends their stereocilia, changing mechanically gated ion-channel opening and producing an electrical response.[ref]
How Do We Hear? by the National Institute on Deafness and Other Communication Disorders. Steps 3–6: cochlear fluid, basilar membrane, hair bundles and auditory signaling
The mechanical response varies along the cochlea, so position contributes to frequency selectivity. The vestibular part of the inner ear instead detects head motion and orientation. The distinction is anatomical and functional: detecting a sound frequency and detecting a rotation of the head use related mechanosensory principles in different structures. Mechanical input, hair-cell response and activity in the associated sensory neurons are successive measurable stages.
A noise-limited dynamic range is the ratio between an upper usable signal level and a lower level defined by a noise criterion, with the observation conditions specified. The lower bound might require a chosen signal-to-noise ratio; the upper bound can be set by amplifier clipping or detector saturation. The ratio depends on bandwidth, integration time, signal convention and acceptance threshold, not only on displayed digits.
For a linear response after offset correction, let the output-noise standard deviation be , the minimum accepted signal be , and the output ceiling be . ThenThese equations assume the stated noise and ceiling apply throughout the interval. Changing alone shifts the input interval without changing under those assumptions. A real amplifier can change noise and bandwidth with gain; the primary specification reports these dependencies separately.[ref]
Datasheet DLPCA-200 by FEMTO. p. 2, integrated RMS input noise and gain-dependent bandwidth; footnote, shielded open-input measurement condition
For an original voltage-amplitude example, take a usable RMS signal ceiling of , RMS zero-mean noise , and . The lower accepted signal is and . As a voltage-amplitude ratio at fixed impedance, this is . If the input quantity instead denotes optical power, its power ratio uses ; the physical quantity must accompany a decibel statement.
Noise density and total noise are different. For a flat one-sided output power spectral density over a specified effective noise bandwidth , the model gives . Increasing fourfold doubles and halves if the ceiling and threshold factor remain fixed. A spectrum with drift or nonwhite components need not obey that scaling.
A noise-limited detection threshold is consequently an operational choice. Five times RMS noise is not a universal minimum detectable signal, nor by itself a statement of false-alarm probability without a noise distribution and observation rule. To characterize a particular instrument, measure its zero-input fluctuations under the actual filtering and loading conditions, then test a stable source near the proposed lower and upper bounds.
Gain ranging changes the sensitivity of a measuring signal path to keep its output within a useful interval as the input changes. A high-sensitivity setting resolves smaller inputs; a lower-sensitivity setting accommodates larger ones before amplifier clipping. Combining the settings can extend the instrument's usable dynamic range, provided their input intervals overlap and their measurement calibration is consistent.
A concrete apparatus is a switchable transimpedance amplifier converting electric current into an output electric potential difference. The DLPCA-200 manufacturer diagram separates a current-to-voltage stage from programmable amplification, and its performance tables give gain-dependent noise, input limits and bandwidth. The settings therefore change more than the decimal point of a display.[ref]
For an original ideal calculation, suppose two settings follow , where is input current, the offset and zero-mean output noise. Stipulate a usable offset-corrected output from to in either setting. With , the input interval is to . With , it is to . Each setting spans a ratio 200, but their overlapping union spans a current ratio 20000. These are stipulated intervals, not specifications for the cited amplifier.
Range-overlap calibration checks that both settings estimate the same current in their common – interval. A range-switching hysteresis rule can switch down in sensitivity above and back up below , reducing repeated switching near one boundary. The output must settle before it is accepted as a new measurement indication.
An analog-to-digital converter that merely changes its printed units cannot recover an already clipped upstream signal. Likewise, increasing amplification does not automatically improve input-referred noise; the new setting may have different noise sources, bandwidth and drift. A meaningful combined range includes these effects and the required measurement uncertainty, rather than multiplying nominal gain settings without checking their usable intervals.
Drug release kinetics describes how the amount leaving a formulation changes with time. Let be the initially releasable amount and the cumulative amount released. The released fraction and instantaneous drug release rate areA fraction has no units; a rate has units of amount per time. These definitions also require stating the releasable amount used for normalization, rather than silently identifying it with every molecule initially loaded.
Several simple models give distinct curve shapes. Constant-rate release gives until the available amount is exhausted. First-order depletion of a reservoir gives , with an amount released per time that declines as the reservoir empties. In a suitable early-time diffusion-controlled drug release regime, a model may instead give . Thenso equal increments of released fraction do not occur in equal time intervals. The square-root expression is a limited-time model, not a law that applies from arbitrarily small times through complete release.
For an illustrative curve , the fractions at one, four and nine hours are , and . The mean fraction released per hour in the intervals –, – and – hours is respectively , and . A plot with equally spaced vertical increments can therefore conceal a strongly changing release rate.
The mechanism must be tested, not inferred solely from a convenient curve fit. Diffusion, material erosion, changing geometry and the measurement apparatus can produce overlapping features. The historical polymer sustained-release work and the modern FDA assay account illustrate the separate tasks of designing a carrier and measuring what it releases.[ref]
Polymers for the sustained release of proteins and other macromolecules by Robert Langer and Judah Folkman. Original sustained-release publication, Nature 263, pp. 797–800
[ref]Adaptive Perfusion: A Novel In Vitro Drug Release Testing Method for Complex Drug Products by the FDA. Technology Summary, rate-limiting measurement transport
A defensible comparison states the time range, normalization, sampling correction and physical assumptions, then checks whether the proposed mechanism is consistent with additional observations.An in vitro drug release test measures the amount or rate at which a substance leaves a formulation under specified laboratory conditions. The medium, temperature, agitation or flow, separation method and sampling schedule define the experiment. A measured release curve is therefore a property of a formulation–apparatus system under those conditions, rather than a direct measurement of the concentration in a person.
A typical design places the formulation in contact with a receiving medium, separates released material from the carrier and measures concentration at several times. The primary FDA technical account describes pressure-driven separation as an alternative to passive dialysis-membrane transport for complex formulations. It emphasizes that the separation step can itself limit the observed rate.[ref]
Adaptive Perfusion: A Novel In Vitro Drug Release Testing Method for Complex Drug Products by the FDA. Technology Summary, pressure-driven separation and limitations of conventional membrane methods
Repeated sampling requires a material balance. Suppose a well-mixed receiver has constant volume . At each observation a volume is removed and replaced with blank medium. If is the concentration immediately before the th withdrawal, the cumulative amount transferred into the receiver by time isThe first term is material still in the receiver; the sum is material removed at earlier observations. This sampling correction in drug release testing assumes matched replacement, a well-mixed receiver and no unmeasured loss or chemical transformation.
For illustrative , , and , the amount at the second observation is , not just . These chosen values demonstrate accounting; they are not a formulation specification or dosing instruction.
An informative experiment also accounts for material retained in the formulation and material lost to the apparatus. Adsorption, incomplete separation or degradation can change a measured concentration without the same change in carrier release. A control without the carrier and a recovery check address different parts of this problem. Comparing the measured curve under several justified apparatus conditions helps distinguish drug release kinetics from transport and analytical limitations.
A DOM text node stores character data within a DOM tree. It represents text content rather than an HTML element with a tag name. One element can contain several text nodes separated by other nodes, and adjacent text nodes can also exist as distinct objects.[ref]
DOM Standard by WHATWG. Text interface and node tree definitions
For example, start with an empty paragraph and append
document.createTextNode("A") followed by document.createTextNode("B"). The paragraph has two child nodes, its combined text content is AB, and it has no element children. Calling paragraph.normalize() merges adjacent text nodes and removes empty ones, so this example then has one text child containing AB.[ref]DOM Standard by WHATWG. Document.createTextNode, Node.textContent and Node.normalize
The distinction matters when editing. An operation expecting the first child to be an element can instead encounter a whitespace text node produced between tags. Traversing all child nodes and traversing only element children answer different questions.
Text insertion also differs from parsing markup. Assigning
paragraph.textContent = "<em>Hi</em>" supplies literal text containing angle brackets; it does not create an emphasis element. A parser-driven operation has different semantics. Finally, rendered whitespace can be collapsed or wrapped by CSS, so the number and contents of text nodes alone do not determine the exact visible line layout.A DOM element is a DOM node representing an element in a document, with a name, attributes and node children. In an HTML document, paragraph and emphasis elements are examples. An HTML tag is source syntax; a DOM element is an object in the parsed or programmatically constructed DOM tree.[ref]
Consider
const p = document.createElement("p"); p.setAttribute("class", "note"); p.textContent = "Ready";. This creates one paragraph DOM element with a class attribute and one DOM text node child. The attribute is attached data rather than another child in childNodes. Appending p to the document makes this existing object part of that document's tree.The element's name, attributes and child content have different roles. Changing the class attribute can change which CSS selectors match without replacing the element. Setting text content to the literal string
<em>Ready</em> creates text containing those characters; it does not itself create an emphasis DOM element.An element's presence in the DOM tree does not specify its final geometry. Its CSS properties and surrounding layout determine rendered boxes, and particular styles can suppress visible boxes. Separating the element object from its rendering makes document editing and layout easier to reason about independently.
Pinned article: Introduction to the OurBigBook Project
Welcome to the OurBigBook Project! Our goal is to create the perfect publishing platform for STEM subjects, and get university-level students to write the best free STEM tutorials ever.
Everyone is welcome to create an account and play with the site: ourbigbook.com/go/register. We belive that students themselves can write amazing tutorials, but teachers are welcome too. You can write about anything you want, it doesn't have to be STEM or even educational. Silly test content is very welcome and you won't be penalized in any way. Just keep it legal!
Intro to OurBigBook
. Source. We have two killer features:
- topics: topics group articles by different users with the same title, e.g. here is the topic for the "Fundamental Theorem of Calculus" ourbigbook.com/go/topic/fundamental-theorem-of-calculusArticles of different users are sorted by upvote within each article page. This feature is a bit like:
- a Wikipedia where each user can have their own version of each article
- a Q&A website like Stack Overflow, where multiple people can give their views on a given topic, and the best ones are sorted by upvote. Except you don't need to wait for someone to ask first, and any topic goes, no matter how narrow or broad
This feature makes it possible for readers to find better explanations of any topic created by other writers. And it allows writers to create an explanation in a place that readers might actually find it.Figure 1. Screenshot of the "Derivative" topic page. View it live at: ourbigbook.com/go/topic/derivativeVideo 2. OurBigBook Web topics demo. Source. - local editing: you can store all your personal knowledge base content locally in a plaintext markup format that can be edited locally and published either:This way you can be sure that even if OurBigBook.com were to go down one day (which we have no plans to do as it is quite cheap to host!), your content will still be perfectly readable as a static site.
- to OurBigBook.com to get awesome multi-user features like topics and likes
- as HTML files to a static website, which you can host yourself for free on many external providers like GitHub Pages, and remain in full control
Figure 2. You can publish local OurBigBook lightweight markup files to either OurBigBook.com or as a static website.Figure 3. Visual Studio Code extension installation.Figure 5. . You can also edit articles on the Web editor without installing anything locally. Video 3. Edit locally and publish demo. Source. This shows editing OurBigBook Markup and publishing it using the Visual Studio Code extension. - Infinitely deep tables of contents:
All our software is open source and hosted at: github.com/ourbigbook/ourbigbook
Further documentation can be found at: docs.ourbigbook.com
Feel free to reach our to us for any help or suggestions: docs.ourbigbook.com/#contact





