Cold cathode Created 2026-10-18 Updated 2026-11-05
A cold cathode supplies electrons without relying on deliberate heating for thermionic emission. The term describes that operating distinction rather than one universal microscopic emission mechanism.
A strong surface electric field can produce field emission; in a gas discharge, particle impact and secondary electron emission can sustain the supply. A cathode may still warm during operation, so cold does not guarantee room temperature. Comparing emitted current as a function of field, illumination or discharge conditions helps distinguish mechanisms. The source's energy spread, stability and emitting geometry matter when it is used in an electron gun.
Electron Created 2026-09-29 Updated 2026-11-05
The electron is an electrically charged elementary particle in the lepton family. It has electric charge , spin and rest mass . The Positron is its antiparticle, with the same mass and opposite charge.
In an atom, atomic orbitals describe electron quantum states rather than tiny classical planetary trajectories. In a material, mobile electrons carry current and can respond to applied electric fields and magnetic fields. An electron gun produces a directed beam whose deflection and interactions make electron imaging and scattering experiments possible. A recorded spot is a detection event; the propagation amplitudes that predict its probability can still interfere.
Electron gun Created 2026-10-18 Updated 2026-11-05
An electron gun creates, accelerates and shapes a directed electron beam. A source such as a heated cathode supplies electrons, an applied electric potential difference accelerates them toward an anode, and electrodes control the emitted current and beam geometry.
For an electron accelerated from rest through potential difference , the ideal gained kinetic energy is , with the voltage sign chosen to accelerate it. Focusing optics then control beam position and convergence. Source size, energy spread and space charge affect the useful beam; increasing accelerating voltage alone does not guarantee a smaller probe or higher image resolution.
Electron microscope Created 2026-10-14 Updated 2026-10-20
An electron microscope forms a spatially enlarged representation of a specimen using electrons, electron lenses, and a detector. Its appeal is access to structure too fine for an ordinary optical microscope, but a short de Broglie wavelength alone does not guarantee fine electron microscope resolution. Increasing magnification can enlarge an existing blur without revealing any additional structure.
In transmission electron microscopy, an electron gun illuminates a thin specimen; magnetic electron lenses form and enlarge its transmitted image on a fluorescent screen or detector. A vacuum reduces collisions with gas. Lens electric currents control focusing and magnification.[ref]
The electron-optical column contains an electron gun, an accelerating supply, a condenser lens system, an objective aperture, an electron objective lens, scan coils and alignment/stigmation controls. The electron gun may use thermionic emission or field emission. The condenser lens system sets the incident probe current and source demagnification; the electron objective lens focuses the probe on the specimen. A movable specimen stage controls position, tilt and working distance. The column and specimen chamber need a vacuum system, appropriate pumps and specimen-transfer hardware. Detectors collect secondary electrons, backscattered electrons or characteristic X-rays; amplification and synchronized raster acquisition assign a measured signal to each image pixel. The first two signals provide different imaging information, while characteristic X-rays allow elemental analysis. A source, probe-forming optics, raster scan, specimen stage, detectors, acquisition electronics and vacuum system form the essential chain.[ref]
A scanning transmission electron microscope makes an image by assigning a transmitted-electron signal to each position of a scanned probe. Its essential chain is electron source, probe-forming optics, scan system, thin specimen, transmitted-electron detectors and synchronized acquisition.
An electron gun and accelerating supply provide a stable beam of the chosen kinetic energy. Condenser lens optics and an aperture control probe current and convergence; the probe-forming objective lens focuses a small spot on the specimen. Alignment, focusing and astigmatism correction keep the probe usable across the field.
Scan coils deflect the probe in a raster. A stable specimen holder positions an electron-transparent region, and a high-vacuum column limits gas scattering and contamination. A bright-field transmission electron microscopy detector collects the central transmitted beam; an annular detector can select annular dark-field electron imaging, including high-angle annular dark-field imaging. Different angular selections give different contrasts, rather than a universal map of height.
Detector electronics, scan timing and a computer assign the collected signal to the corresponding image pixel. Spectrometers are useful additions but not essential to basic image formation. The post-specimen optics can adjust detector collection geometry; they do not set scan-image magnification in the same way as the projection lenses of conventional transmission imaging.
Figure 1.
Original schematics of scanned transmitted-electron imaging and contact-mode force feedback; panels show different instruments
. Details.
An electron gun releases electrons by thermionic emission, field emission or photoelectric effect, accelerates them through an electric potential, and uses electrostatic or magnetic lenses to form a beam in vacuum. A hot unpolarized cathode does not by itself select spin.
For a polarized source, illuminate a suitable semiconductor photocathode, commonly strained GaAs, with circularly polarized light near its band-gap threshold. Optical angular-momentum selection rules preferentially populate one conduction-electron spin; emission from a negative-electron-affinity surface extracts the selected population. Reversing the light's circular polarization reverses the beam polarization. Strain and a suitable excitation wavelength suppress transitions that dilute the selection. Solenoids and spin rotators orient the spin after acceleration, and a scattering polarimeter measures the achieved polarization; it need not be .
Consider two ideal thin electron lenses in successive imaging stages. In each stage choose positive object and image distances for a real image, measured from its effective lens plane, and neglect the image rotation of a magnetic electron lens. The paraxial approximation gives
The product follows directly by writing and . Here is transverse magnification, rather than the enlargement applied later to a photograph. Both inversions cancel in this planar model; actual magnetic electron lenses can additionally rotate the image.
For an original worked example, take , , and . Then
A object interval becomes at the screen. The second lens sits after the first. These are calculated distances, not measurements of the 1931 instrument.
Figure 1.
Two electron lenses relay an object into an enlarged screen image
. Original paraxial approximation construction for the worked example, in a frame neglecting magnetic image rotation. Three illustrative trajectories from one off-axis point meet at the intermediate image and again at the screen. The shaded bands represent effective magnetic lens regions; real trajectories bend smoothly. The dashed enclosure represents a vacuum column, with an upstream electron gun and a pump connection indicated schematically. Horizontal and vertical scales differ; neither the geometry nor the rays reproduce historical apparatus measurements. Source. Details.
To measure magnification, divide a screen interval between corresponding grid features by the independently known object interval. Repeat over several periods to reduce endpoint uncertainty. For a proposed check, record accelerating voltage, lens electric currents, screen position and specimen orientation; compare one-stage and two-stage images, refocusing as necessary. Changing a lens electric current should change focus and scale, while a blank exposure checks detector background. Keep irradiation and recording enlargement controlled, and repeat the original setting to test drift or specimen damage. These are suggested checks, not a claim that every check was performed in 1931. A grid-scale measurement establishes magnification; resolving much finer features requires a separate target and contrast criterion.