Replacing the fixed surface temperature by Newton's law of cooling changes the boundary condition but not the radial derivative in steady state. At the surface,
Hence
Here is a surface heat transfer coefficient in , unrelated to the surface tension symbol used in C10. An independent energy-balance check uses a length : the electrical input must equal the surface loss , which gives the same answer.
The complete temperature profile is
Thermal conductivity controls the internal gradient, but cancels from the surface-temperature rise because all generated power must eventually cross the prescribed surface. This assumes positive constant , uniform electrical conductivity and negligible end or additional radiative losses; temperature-dependent material properties could make the heating and boundary problem nonlinear.