Alexander R. Opotowsky 2026-11-05
Alexander R. Opotowsky is a physician whose research includes adult congenital heart conditions, exercise physiology and evaluation of cardiac output measurements. His institutional profile identifies these scientific interests.[ref]
Alexander Opotowsky profile at Cincinnati Children's. Research interests: exercise physiology, pulmonary vascular disease and right ventricular function
In a 2017 primary study, Opotowsky and colleagues compared paired thermodilution and estimated-oxygen-uptake Fick principle measurements from 12,232 adults in a Veterans Affairs cohort and 3,391 adults at Vanderbilt. The investigators examined method agreement and subsequent mortality associations.[ref]
Thermodilution vs Estimated Fick Cardiac Output Measurement in Clinical Practice by Alexander R. Opotowsky and others. Abstract, Design, Exposures and Main outcomes; JAMA Cardiology 2, 1090–1099, DOI 10.1001/jamacardio.2017.2945
Comparing two methods does not make either an error-free ground truth.The measurement distinction can be explained by oxygen-uptake assumptions in estimated Fick output. At steady state, the oxygen Fick principle writeswhere is cardiac output, the numerator is oxygen consumption per unit time and the denominator is the arterial-minus-mixed-venous oxygen content difference. Estimating the numerator from an external formula introduces an assumption that directly scales the inferred cardiac output; it is distinct from measuring oxygen consumption.
For stipulated oxygen uptake of 200 mL/min and a content difference of , L/min. Substituting an estimated uptake of 250 mL/min gives 5 L/min, a 25% increase with unchanged content measurements. This is an original error-propagation example, not a patient result or a universal performance estimate. Errors in the content difference can also affect the ratio.
The primary study found that a small average difference between methods coexisted with wide limits of agreement.[ref]
Thermodilution vs Estimated Fick Cardiac Output Measurement in Clinical Practice by Alexander R. Opotowsky and others. Abstract, Results; Figure 1, paired-method differences
Positive and negative discrepancies can cancel in a mean while remaining substantial for individuals. This separates average bias, individual agreement and prognostic association, rather than treating all three as one measure of accuracy. Alicia M. Maceira 2026-11-05
Alicia M. Maceira is a physician working in cardiology and cardiac imaging. Her hospital profile identifies cardiac diagnostic imaging as her specialization.[ref]
Alicia Maceira profile at Hospital Ascires. “Cardióloga” and “Especialista en Diagnóstico Cardiológico por Imagen”
Her primary research includes establishing right ventricle reference measurements with magnetic resonance imaging.In a 2006 paper, Maceira and colleagues studied 120 healthy adults, 60 men and 60 women aged 20–80 years, using cine images acquired by steady-state free-precession imaging and three-dimensional modelling. The study examined how age, sex and body surface area related to ventricular volumes and function.[ref]
Reference right ventricular systolic and diastolic function normalized to age, gender and body surface area from steady-state free precession cardiovascular magnetic resonance by Alicia M. Maceira and others. Abstract, Methods and results; European Heart Journal 27, 2879–2888, DOI 10.1093/eurheartj/ehl336
An original numerical example separates the measurements. If end-diastolic volume is 150 mL and end-systolic volume is 60 mL, the volume difference is 90 mL and right ventricular ejection fraction is . Dividing the 150 mL end-diastolic volume by a body surface area of gives an indexed volume of approximately . The fraction and the indexed volume describe different properties; neither numerical value alone specifies a universal reference interval.
The study found associations with age even for several size-normalized measurements. This motivates population conditioning of ventricular reference intervals: scaling by body surface area need not eliminate all dependence on age or sex.[ref]
Reference right ventricular systolic and diastolic function normalized to age, gender and body surface area from steady-state free precession cardiovascular magnetic resonance by Alicia M. Maceira and others. Abstract, Results and Conclusion
Reference values also belong to an acquisition and analysis procedure. A numerical example explains the quantities; clinical interpretation requires the appropriate validated reference framework.Alicia Maceira, identified on her official Hospital Ascires cardiology profile.
Bartley P. Griffith 2026-11-05
Bartley P. Griffith coauthored the 1994 experiment comparing image-derived ventricular area with a balloon-based pressure-volume reference. The publisher's full byline directly verifies the identity. The study used perfused dog hearts, a micromanometer catheter and automated echocardiography to investigate estimates of ventricular compliance.[ref]
His university profile identifies his professional field as surgery, including heart and lung transplantation and the development of circulatory-support devices.[ref]
Bartley P. Griffith faculty profile by University of Maryland School of Medicine. Primary Appointment and Biosketch, Personal Statement
A central issue is the conversion between a geometric surrogate and the mechanical quantity of interest. If volume and area are linked by a differentiable relation , the chain rule givesThe reciprocal slope has area-per-pressure units, whereas ventricular compliance has volume-per-pressure units. They require a geometric conversion before being interpreted as the same physical quantity.
For an original local example, suppose and . Then mmHg/mL and mL/mmHg. Simply copying the area-pressure inverse slope would give 0.5 square centimetres per mmHg, a different observable.
This illustrates why an experimental reference is valuable even when the surrogate and reference curves have similar shapes. The paper's abstract explicitly confines its conclusion by noting that clinical application remains to be validated.[ref]
Bartley P. Griffith, identified portrait linked from his University of Maryland faculty profile
. Brian Diffey 2026-11-05
Brian Diffey, credited as B. L. Diffey in the primary byline, coauthored the 1983 study of optical transmission through human toenails with S. G. Parker. The paper measured thirteen autopsy toenails at fifteen wavelengths between 300 and 600 nm using a monochromator, integrating sphere and photodiode; its analysis included a correction for nail fluorescence.[ref]
The transmission of optical radiation through human nails by S. G. Parker and B. L. Diffey. Abstract and byline, British Journal of Dermatology 108, 11–16, DOI 10.1111/j.1365-2133.1983.tb04573.x
Newcastle University's named profile identifies Brian Diffey as a photobiology researcher, lists work under the initials B. L. Diffey and records his medical-physics work at Dryburn Hospital, the affiliation given for the nail paper. His research interests include measuring human exposure to ultraviolet radiation.[ref]
Brian Diffey profile at Newcastle University. Background, Research Interests and Publications; Dryburn Hospital history and Diffey BL entries
The research attribution here is collective; a joint byline does not establish which author performed a particular apparatus task.The nail experiment illustrates fluorescence contamination in nail-transmission measurements. A light detector can register both incident-wavelength light transmitted through a sample and light emitted at other wavelengths. In an original linear detector model,where is spectral responsivity and is spectral radiant power. Converting the total detector current into transmittance requires separating those contributions or specifying a valid correction. The detector's response at the emitted wavelengths need not equal its response at the illumination wavelength.
For an illustrative already power-calibrated signal, suppose incident power is 1.00 mW and the collected signal contains 0.08 mW of transmitted illumination plus 0.02 mW of fluorescence. Treating all detected power as transmitted illumination gives 10% instead of 8%, a 25% relative overestimate. These are invented values explaining the measurement issue, not data reported by the authors. Their explicit fluorescence correction shows why a detector reading alone does not define the desired optical quantity.
Christopher M. Kramer 2026-11-05
Christopher M. Kramer is a cardiologist whose research uses cardiovascular magnetic resonance imaging to assess the heart. His University of Virginia profile identifies cardiovascular imaging as an area of expertise.[ref]
Christopher M. Kramer profile at UVA Health. Bio & Overview
He is the first author of the 2020 primary protocol document specifying standardized cardiovascular magnetic resonance imaging acquisitions.[ref]One concrete contribution of such a protocol is to make image geometry reproducible. Its left-ventricular procedure links the cardiac apex, mitral valve center, cardiac long axis views and a cardiac short-axis stack.[ref]
Standardized cardiovascular magnetic resonance imaging (CMR) protocols: 2020 update by Christopher M. Kramer and others. Left ventricular structure and function, items 3 and 6; Figures 1–3
The geometry determines which anatomy is acquired before an analyst draws a cavity boundary.An original example explains the measurement consequence. A volume reconstructed as depends on both the cavity areas and the represented slice thicknesses. If ten slices each have area 8 cm and represented thickness 0.8 cm, the estimate is 64 mL. Omitting one such slice loses 6.4 mL even if every retained boundary is traced perfectly. Standardized coverage and phase selection therefore address errors that cannot be removed merely by improving image segmentation on the available slices.
The documented protocol work connects acquisition choices to interpretable measurements of chamber structure and function. It provides technical procedures and reference geometry; the arithmetic example here illustrates their purpose rather than reporting a result from that document.