J. Bartels is the first named author of the 1954 primary study comparing respiratory dead space measurements using single-breath analysis of oxygen, carbon dioxide, nitrogen or helium. The journal supplies the initial-only byline; it does not establish a fuller personal name. The measurement contribution concerns the relationship between expired gas composition and expired volume.[ref]
The Respiratory Dead Space Measured by Single Breath Analysis of Oxygen, Carbon Dioxide, Nitrogen or Helium by J. Bartels and others. p. 41, primary byline, study title and opening measurement description
A single expired breath is not compositionally uniform. Conducting-airway gas appears before gas from exchanging regions, with a transition that depends on mixing and measurement response. Pairing mouth-flow recording with gas-fraction recording allows elapsed time to be converted into an expired-volume coordinate. Synchronization matters because a gas analyser can respond later than the flow sensor.
An original idealized washout curve makes the volume interpretation concrete. Suppose a tracer fraction is zero over the first 100 mL, rises linearly to its plateau over the next 100 mL, and then stays at a plateau value . The equivalent sharp-boundary volume under this flat-plateau model isThe transition contributes half its width. This synthetic equal-area construction explains a measurement principle; it is not a reported observation from Bartels's subjects.
A sloping plateau, incomplete tracer equilibration or analyser delay can change the inferred boundary. Comparing tracers therefore tests a physiological measurement model as well as an instrument. Bartels's verified authorship belongs to that gas-analysis experiment, without claiming that the initial-only name identifies a particular namesake or that every definition of respiratory dead space gives an identical volume.
C. B. McKerrow coauthored the 1959 primary report with Basil Martin Wright on maximum forced expiratory flow and a portable instrument for measuring it. The primary record retains the initials C. B.; no fuller name is established here. The scientific contribution links a compact flow measurement to quantitative assessment of ventilatory performance.[ref]
Maximum Forced Expiratory Flow Rate as a Measure of Ventilatory Capacity by Basil Martin Wright and C. B. McKerrow. Primary byline; BMJ 2(5159), pp. 1041–1046; indexed subtitle on the portable instrument
Peak expiratory flow is the maximum of the expiratory volume-flow curve, whereas expired volume is its time integral:A maximum and an integral preserve different information. Their distinction motivates a flowmeter even when a volume measurement is also available.
For two original triangular flow pulses, let one have height 8 L/s and base duration 0.25 s, and the other height 4 L/s and duration 0.50 s. Both enclose 1 L, but their peak flows are 480 and 240 L/min. Equal expired volumes therefore do not imply equal peak flow. These stipulated traces are not human reference values or results assigned to McKerrow's experiment.
The surviving Wright instrument is documented by a primary museum collection record, including its portable construction and a dial graduated in litres per minute.[ref]
Wright Peak Flowmeter at the Wood Library-Museum of Anesthesiology. Object description and catalogue, accession 1998-02-25-1
Such an instrument supplies a specific observable. It does not, from one peak alone, reconstruct the entire expiratory curve or distinguish every possible cause of an altered measurement.Basil Martin Wright was a physician and instrument developer associated with the portable Wright peak flowmeter. The primary museum catalogue explicitly connects B. M. Wright with the full name Basil Martin Wright, and the 1959 paper with C. B. McKerrow presents maximum forced expiratory flow as a measurable index with a new portable instrument.[ref]
Wright Peak Flowmeter at the Wood Library-Museum of Anesthesiology. Named inventor description; catalogue Author field, accession 1998-02-25-1
[ref]Maximum Forced Expiratory Flow Rate as a Measure of Ventilatory Capacity by Basil Martin Wright and C. B. McKerrow. Primary byline and instrument-report title
The practical motivation was portability: the museum describes the earlier available lung-volume apparatus as bulky, while the Wright instrument enabled measurements outside the laboratory. Its dial reports peak expiratory flow in litres per minute. Portability changes where an observation can be made, while dynamic response determines what part of a rapid flow event is preserved.
An original sensor model illustrates that second issue. Suppose a hypothetical readout obeys , initially at zero. A rectangular input of height lasting produces a maximumFor , the reading reaches only about 63.2% of the actual peak before the input stops. This is a deliberately simplified low-pass sensor, not a claim that the Wright meter has that transfer function. It shows why static measurement calibration alone does not establish accuracy for a short expiratory peak.
Wright's documented contribution makes a useful distinction between physiological quantities and their instrumentation: a conveniently retained peak is valuable because it can be measured repeatedly, but it is still a peak rather than a full record of volume, timing and flow. The collection's tentative dating of its particular specimen is not treated as an exact invention date.
Ahmet Baydur is first author of the 1982 primary study testing an esophageal balloon method for estimating pleural pressure. His official faculty profile identifies respiratory mechanics and control of ventilation among his research interests.[ref]
A Simple Method for Assessing the Validity of the Esophageal Balloon Technique by Ahmet Baydur and others. Primary byline; abstract, experimental objective
[ref]The esophageal balloon occlusion test experiment occluded the airway at end expiration in ten subjects and compared changes of esophageal and mouth pressure during ensuing inspiratory efforts. It tested sitting, supine and lateral positions. The reported pressure-change ratio was near unity in sitting and lateral positions; some supine deviations could be reduced by repositioning the balloon. This made balloon placement and posture testable parts of the measurement rather than assuming that any esophageal pressure trace was an adequate surrogate.[ref]
A Simple Method for Assessing the Validity of the Esophageal Balloon Technique by Ahmet Baydur and others. Abstract, occlusion protocol, posture comparison and repositioning observations
For an original reduction, suppose an occluded effort changes mouth pressure by cm of water and esophageal pressure by cm of water. The change ratio is . If repositioning gives cm of water at the same mouth change, the ratio becomes 0.98. These invented numbers illustrate the comparison; they are not observations from the paper or a prescribed acceptance threshold.
A change ratio also cannot determine a constant offset. If , then for fixed . Agreement of changes therefore addresses pressure transmission under the tested conditions, rather than proving equality of every absolute pressure reading.
Ahmet Baydur, identified portrait linked from his USC faculty profile
. Robert L. Kormos is a named coauthor of the 1994 primary study estimating ventricular compliance from automated echocardiography and pressure measurements. The publisher supplies the full name and describes the shared isolated-heart measurement experiment.[ref]
Estimation of left ventricular compliance using on-line echocardiographic automated border detection and pressure data by John Gorcsan III and others. Publisher full byline; abstract, study objective
The apparatus makes the reference quantity unusually concrete: an intraventricular balloon supplies known volume changes, rather than inferring every volume from the same image being tested. A micromanometer records pressure, and a computer interface pairs it with short-axis ventricular area.
An original calibration example separates absolute volume from its increments. If a reference has a fixed offset , then and . The offset does not disappear from the reported absolute volumes. If instead , the inferred ventricular compliance is multiplied by . With true compliance 4 mL/mmHg and , it becomes 4.2 mL/mmHg. Agreement about increments is therefore different from agreement about the curve's absolute location.
The primary experiment varied balloon volume repeatedly and compared image-area and volume-based pressure relations. Its favorable experimental correspondence and explicit need for clinical validation document a methodological contribution, without establishing an identical result for every chamber or loading condition.[ref]
Akihiko Kawai is a verified coauthor of the 1994 study estimating ventricular compliance by automated echocardiography and paired pressure measurements. The publisher supplies the full name. An intraventricular balloon provided volume, a micromanometer supplied pressure and short-axis boundary detection supplied ventricular area in six perfused dog hearts.[ref]
Estimation of left ventricular compliance using on-line echocardiographic automated border detection and pressure data by John Gorcsan III and others. Publisher full byline; abstract, experimental preparation
The scientific target is a chamber's pressure-volume behavior. A chamber can have the same volume in two mechanical states while requiring different distending pressures; volume alone does not identify compliance.
For an original pair of linear passive models, take and , with volume in mL and pressure in mmHg. At mL, the pressures are 4 and 8 mmHg. The corresponding compliances are and mL/mmHg. Equal volume therefore coexists with a twofold difference in this derivative. These are explanatory chambers, not measurements or reference values from Kawai's study.
The experiment tested whether the image-derived pressure-area relation could track a known pressure-volume reference under its acquisition conditions. The abstract reports favorable agreement but reserves clinical validation.[ref]
Estimation of left ventricular compliance using on-line echocardiographic automated border detection and pressure data by John Gorcsan III and others. Abstract, comparison and clinical-validation limitation
That evidence documents Kawai's participation in a specific physiological measurement problem without guessing a separate personal task, date of birth or broader biography.Shigeki Morita is a coauthor of the 1994 isolated-heart study comparing automated echocardiography with a pressure-volume reference for ventricular compliance. The exact full name appears in the publisher byline. The experiment combined intraventricular balloon volumes, micromanometer pressure and image-derived short-axis area.[ref]
The study's replication has two levels: three runs of changing volume were performed in each of six hearts. Repeated observations help describe a curve within a preparation, while different hearts supply biological replication. The reported 1,080 simultaneous measurements are not 1,080 independent hearts.[ref]
An original error model shows why that distinction matters. Let , with independent heart-level effects of variance and independent within-heart errors of variance . For hearts and observations per heart,Adding more measurements to the same heart reduces the second term but not the first. This stipulated model is not a reanalysis of the study's observations; it illustrates how the apparatus and replication structure shape the scientific question.
Morita's verified contribution is coauthorship of that measurement experiment. Its evidence supports the tested preparation and does not establish universal interchangeability of imaging area and chamber volume.
Lee G. Deneault coauthored the 1994 primary experiment relating image-derived ventricular area, measured pressure and balloon-reference volume. The publisher gives the full name, and the paper's abstract describes automated boundary detection linked to simultaneous computerized pressure-area acquisition.[ref]
This work addresses an important distinction between correlation and numerical agreement. A surrogate can track changes extremely consistently while retaining a scale or offset error. For original reference volumes 10, 20 and 30 mL, let a hypothetical estimator give mL. It yields 17, 29 and 41 mL. The Pearson correlation coefficient is exactly one, yet every estimate is biased upward and the change scale is 20% high.
Likewise, a strong relation between pressure-area and pressure-volume measurements does not by itself make area and volume interchangeable. Their units and geometric conversion differ. A useful validation compares the actual relationship, its repeatability and the conditions under which the surrogate is applied.
The primary abstract reports both correlations and fitted-curve comparisons, then states that clinical application remains to be validated.[ref]
Estimation of left ventricular compliance using on-line echocardiographic automated border detection and pressure data by John Gorcsan III and others. Abstract, regression comparisons and final qualification
This establishes Deneault's participation in a concrete imaging-validation study without attributing the illustrative error model or an individually invented role to him.William A. Mandarino is a named coauthor of the 1994 study estimating ventricular compliance from automated echocardiography and pressure measurements in an isolated-heart preparation. The full publisher byline establishes this identity and the shared contribution; it does not assign a separate experimental task to each coauthor.[ref]
The method pairs image-derived ventricular area with simultaneously acquired pressure, using a balloon volume as an experimental reference. A micromanometer's pressure zero and the chamber's external pressure are different inputs to interpreting that relation.
For an original measurement model, suppose the recorded pressure is , with constant offset . Then : a fixed zero offset moves a curve vertically without changing its local derivative. By contrast, a gain error givesIf , inferred ventricular compliance is about 9.09% low even though the curve retains the same qualitative shape. These stipulated errors explain why measurement calibration matters; they are not errors reported for Mandarino's apparatus.
The study's repeated paired measurements therefore concern a quantitative mapping, not just acquisition of a recognizable heart image. Its experimental results support the tested preparation, while the abstract explicitly reserves validation in clinical use.[ref]
Estimation of left ventricular compliance using on-line echocardiographic automated border detection and pressure data by John Gorcsan III and others. Abstract, simultaneous acquisition, repeated volume runs and stated limitation
John Gorcsan III is first author of the 1994 experimental study comparing automated echocardiography with known ventricular volume and measured pressure to estimate ventricular compliance. The publisher explicitly supplies his full name. The experiment used six perfused dog hearts, an intraventricular balloon, a micromanometer catheter and computer-linked short-axis border measurements.[ref]
Estimation of left ventricular compliance using on-line echocardiographic automated border detection and pressure data by John Gorcsan III and others. Publisher byline; abstract, isolated-heart apparatus and study objective
The methodological question is how a two-dimensional image can track a three-dimensional chamber. The balloon supplies a volume reference, while the ultrasound boundary supplies an area; agreement must be tested rather than assumed from visual resemblance.
An original geometry example makes the distinction quantitative. Under uniform scaling of an unchanged shape, area scales as and volume as , so for a shape-dependent constant . A ten-percent area increase then predicts a volume factor , rather than 1.10. This is a homothetic model, not the study's asserted ventricular shape or an independent volume measurement.
The paper reports strong correspondence between its pressure-area and pressure-volume relationships but explicitly leaves clinical application to further validation.[ref]
Estimation of left ventricular compliance using on-line echocardiographic automated border detection and pressure data by John Gorcsan III and others. Abstract, comparison results and final clinical-validation qualification
Gorcsan's verified contribution here is leadership of that measurement study, not a claim that every image-area change is already a calibrated volume change.William A. Zoghbi chaired the 2017 technical report on noninvasive evaluation of native heart valve regurgitation, developed by the American Society of Echocardiography with the Society for Cardiovascular Magnetic Resonance. The primary title page names him as chair.[ref]
Recommendations for Noninvasive Evaluation of Native Valvular Regurgitation by William A. Zoghbi and others. Title page and author byline
His documented contribution includes a shared quantitative framework connecting valve anatomy, Doppler echocardiography and volumetric measurements.The report defines complementary ways to assess regurgitant volume and regurgitant fraction, rather than equating a jet's visual size with the whole amount of backward blood flow.[ref]
Recommendations for Noninvasive Evaluation of Native Valvular Regurgitation by William A. Zoghbi and others. Section II.B.6; Figure 8, volumetric assessment
The quantities depend on which surfaces, time intervals and volume conventions the observations represent.An original measurement example distinguishes shared and unequal scale errors. Suppose total ventricular stroke volume is 90 mL and matched forward volume is 60 mL, giving RF . If both estimates are multiplied by the same gain , their ratio remainsIf only the forward estimate is 10% high, however, the apparent RF becomes . A normalization removes one common factor but does not remove every acquisition or reconstruction error. These are chosen values, not an accuracy result from the report.
This illustrates why combining measurements requires knowing their common inputs and their independent limitations. Anatomical imaging, integrated flow and chamber-volume reconstruction supply different information. Zoghbi's verified report leadership belongs to that methodological integration, without attributing every coauthor's technique or a hypothetical error model to him individually.
Nirav R. Bhakta is first author of the 2023 European Respiratory Society/American Thoracic Society technical statement standardizing measurement of lung volumes. The report defines lung-volume subdivisions and distinguishes body plethysmography from gas-dilution measurements.[ref]
Standardisation of the measurement of lung volumes, 2023 update by Nirav R. Bhakta and others. Primary byline; Definitions and subdivisions of lung volume, Figure 1; Measurement of FRC
This is a contribution to making physiological measurements comparable across acquisition systems and laboratories.The relationships among functional residual capacity, inspiratory capacity, expiratory reserve volume, total lung capacity and residual lung volume are also a useful test of data reduction. For an original accounting example, writeSubtracting gives vital capacity . At stipulated FRC 3 L, IC 2 L and ERV 1 L, the derived values are TLC 5 L, RV 2 L and VC 3 L. These are illustrative inventories, not clinical reference values.
The same recorded FRC enters TLC and RV with the same coefficient. If independent FRC, IC and ERV estimates each have standard uncertainty 0.10 L, the derived TLC and RV each have variance , but their covariance is . HenceThe standard uncertainty is about 0.141 L, matching direct propagation through IC + ERV. Incorrectly treating the two derived capacities as independent gives 0.20 L instead.
Bhakta's technical work helps make the definitions and acquisition conditions behind such comparisons explicit. The algebra does not establish that a gas-dilution estimate and a plethysmographic estimate sample exactly the same accessible gas in every circumstance. A consistent volume identity and an appropriate measurement mechanism are separate requirements.
Arthur B. DuBois is first author of the 1956 primary report introducing a rapid plethysmographic measurement of thoracic gas volume and comparing it with a nitrogen-washout measurement of functional residual capacity in normal subjects.[ref]
A rapid plethysmographic method for measuring thoracic gas volume by Arthur B. DuBois and others. Title and primary byline, JCI 35, pp.322–326
The experiment turns a gas-compression relation into an observable pressure-volume slope.The apparatus enclosed the subject in a sealed chamber, used a mouthpiece shutter and recorded chamber and mouth-pressure signals with capacitance manometers on a cathode-ray oscillograph. Chamber calibration related its pressure signal to changes in body volume.[ref]
A rapid plethysmographic method for measuring thoracic gas volume by Arthur B. DuBois and others. Method, p.323 and Figure 1
This supplied simultaneous signals rather than an estimate from one uncalibrated pressure reading.An original Boyle's law example follows the paper's derivation. For an approximately isothermal closed gas compartment,Here is the signed change in gas volume, not a raw chamber-pressure signal. If , the approximation is . The original article derives the same exact-to-small-change distinction.[ref]
For stipulated kPa, compression L and pressure rise kPa, the exact expression gives 3.03 L and the small-change approximation gives 3.00 L. Their 0.03 L difference is an approximation effect in the chosen gas model, not observed instrument error in the study.
The experiment also depends on the relationship between mouth and alveolar pressure. The paper explicitly discusses failures when that relationship is disrupted.[ref]
A rapid plethysmographic method for measuring thoracic gas volume by Arthur B. DuBois and others. Method, p.323, unsatisfactory tracings
DuBois's contribution combines the physical law, pressure sensing, chamber calibration and tests of the assumptions needed to interpret the signal.C. Carlhäll is first author of a 2007 experiment quantifying how mitral annulus motion contributes to left ventricular filling. The study implanted markers in the ventricular wall and around the annulus in six sheep, then used biplane fluoroscopy to reconstruct three-dimensional marker motion.[ref]
Contribution of mitral annular dynamics to LV diastolic filling with alteration in preload and inotropic state by C. Carlhäll and others. Byline; Abstract, marker implantation and biplane reconstruction
This makes boundary movement an experimentally measured part of chamber filling, rather than treating the valve plane as stationary.The investigators estimated enclosed volumes using multiple tetrahedra defined by the reconstructed markers.[ref]
Contribution of mitral annular dynamics to LV diastolic filling with alteration in preload and inotropic state by C. Carlhäll and others. Abstract, tetrahedral volume estimates
Changing marker positions can change both the annular area and its excursion. Their contributions cannot generally be recovered from one distance alone.An original geometric example takes a tetrahedron with one vertex at the origin and the other vertices at , and cm. Its volume isMoving only the last vertex to cm increases this to . Translating all four vertices by the same vector leaves the volume unchanged, because the relevant vectors are differences between vertices. This illustrates the reconstruction geometry, not measured animal dimensions.
A boundary-swept volume and the amount of blood crossing that boundary are nevertheless distinct observables. Interpreting their relationship requires a consistent moving-boundary model and matching cardiac phases. The primary work compared annular dynamics under altered loading and contractile conditions; its contribution is the quantitative experimental connection between three-dimensional motion and filling. The original initial-only byline is preserved without inferring an expanded identity from a separate profile.
Marcus Carlsson investigates cardiac pumping using magnetic resonance imaging. His 2007 primary study measured longitudinal atrioventricular-plane displacement and related it to stroke volume in twelve controls, twelve elite triathletes and twelve patients with dilated cardiomyopathy.[ref]
The study combined a longitudinal displacement with a short-axis area to estimate the longitudinal contribution to ejected volume.[ref]
Atrioventricular plane displacement is the major contributor to left ventricular pumping in healthy adults, athletes, and patients with dilated cardiomyopathy by Marcus Carlsson and others. Abstract, calculation from mean epicardial area and displacement
A shorter displacement need not imply a proportionally smaller contribution when the chamber's transverse dimensions differ.An original constant-area illustration givesWith stipulated and cm, the modeled contribution is 40 mL. Doubling area to while halving displacement to 0.5 cm gives the same 40 mL. If total stroke volume is 80 mL in both examples, both longitudinal fractions are one half. These are geometric examples, not group values from the study.
This explains why comparing displacement alone and comparing its contribution to stroke volume are different questions. The experimental paper supplies actual images and a specified geometric estimator, while the toy model isolates the multiplication responsible for that distinction. Neither a displacement nor its volume fraction alone determines every aspect of ventricular function; ejection fraction also requires the corresponding chamber volume.
Marcus Carlsson, named portrait linked from his Karolinska Institutet profile
. Laura L. Koth is a pulmonologist whose institutional profile describes research on lung inflammation and macrophage activation.[ref]
Laura L. Koth profile at UCSF Health. About me, clinical specialty and research focus
With Warren M. Gold, she coauthored the technical chapter Pulmonary Function Testing, which explains how instrument observations are converted into respiratory quantities.[ref]Pulmonary Function Testing by Warren M. Gold and Laura L. Koth. Primary chapter byline and Gas Dilution Methods
A useful example is the chapter's closed-circuit helium dilution method. A known tracer amount mixes with communicating lung gas; its final concentration provides information about the initially unlabelled gas volume. The chapter also distinguishes such indirect measurements from the volume changes available through spirometry.[ref]
Pulmonary Function Testing by Warren M. Gold and Laura L. Koth. Gas Dilution Methods and Figure 25-10
For an original ideal balance, suppose a chamber initially contains volume with helium fraction , and the connected lung compartment contains no helium. If there is complete equilibration, no leak or tracer loss, and all volumes use the same pressure and temperature basis,Choosing L, and final fraction gives L. These are stipulated values, not a clinical test protocol or measurements from Koth's work.
The model identifies the gas volume that equilibrates under its assumptions. An additional compartment that does not communicate with the tracer would not contribute to that same dilution signal. Better precision in the final concentration does not establish that the entire anatomical volume was sampled. This is why measurement mechanism, equilibration and the intended physiological quantity must be stated together.
Koth's documented contribution combines pulmonary research with quantitative interpretation of lung-function measurements. The chapter is jointly authored; its individual methods are not attributed exclusively to one coauthor.
Warren M. Gold, with Laura L. Koth, coauthored Pulmonary Function Testing, a technical account of how respiratory measurements relate to the mechanical and gas-exchange behavior of the lungs.[ref]
Pulmonary Function Testing by Warren M. Gold and Laura L. Koth. Primary chapter byline and sections on lung volumes
The contribution is a quantitative synthesis of methods and their interpretations; the jointly authored chapter does not assign its individual methods to one coauthor.An important distinction is between a change in lung gas volume and the absolute amount left behind after expiration. The chapter explains that spirometry measures volume changes, while residual lung volume requires an indirect determination. It also shows that reduced vital capacity can accompany different underlying volume configurations.[ref]
In an original inventory example, let total capacity be and residual volume be . The available change between those endpoints isThe pairs L and L both give L. Measuring the same volume change does not identify which absolute-volume pair produced it. Adding an arbitrary constant to both endpoints leaves their difference unchanged.
A separate measurement that constrains one endpoint can remove that particular ambiguity. For example, knowing L as well as L gives L. That does not make every indirect volume method interchangeable: tracer equilibration, pressure/temperature conventions and communicating compartments still enter their measurement models.
Gold's documented technical work helps distinguish the physiological quantity from its instrument signal. More reproducible measurements of an unchanged difference cannot recover an unknown offset merely by averaging. The observed quantity, the supplementary information and the model connecting them all belong in a scientific account of a lung-function test.
Pierre Tawfik is first author of a 2022 pilot study comparing static and dynamic estimates of respiratory-system compliance and driving pressure during passive mechanical ventilation.[ref]
Static and Dynamic Measurements of Compliance and Driving Pressure: A Pilot Study by Pierre Tawfik and others. Primary byline; Study Design
The distinction concerns how pressure and volume are sampled, rather than two names for an automatically identical material constant.The paper compared methods using equilibrated plateau pressure, the first zero-flow pressure, the pressure-volume slope during constant-flow inflation and expiratory time constants.[ref]
Static and Dynamic Measurements of Compliance and Driving Pressure: A Pilot Study by Pierre Tawfik and others. Introduction and Figure 1, methods A–D
Its results concern the respiratory system, including the lungs and chest wall; they should not silently be relabeled as lung compliance alone.An original quasistatic model illustrates the boundary distinction. If the same volume change stretches the lungs and chest wall, their required pressure changes add:Here is lung compliance and chest-wall compliance. At stipulated and , the system compliance is approximately . A 0.50 L change needs 7.5 cm of water across the combined elastic system, of which 5 belongs to the lung term. These are chosen linear-model values, not measurements from Tawfik's cohort.
During flow, an additional resistive pressure contribution can occur. Relaxation after flow stops can also change the observed pressure. Consequently, specifying system boundaries and sampling time is necessary before interpreting a computed volume/pressure ratio. The primary experiment tests those methodological distinctions in the same clinical setting; the simple series-compliance calculation isolates only one reason why different quantities must be kept separate.
Brian L. Graham is first author of the 2019 official American Thoracic Society and European Respiratory Society statement standardizing spirometry. The document specifies equipment checks, acquisition quality and the definitions used to compare forced expiratory measurements.[ref]
Standardization of Spirometry 2019 Update by Brian L. Graham and others. Title page, primary byline; Equipment and Device Quality Assurance; FVC Maneuver
Standardization connects an instrument's numerical output to a reproducible physiological observation.A basic distinction is between airflow and accumulated expired volume. For a flow-sensing instrument with correct zero and a defined start time,An original flow example takes for , with expressed in seconds. It gives L, about 2.36 L at one second and 5.19 L at four seconds. The model is not a reference human expiratory curve; it illustrates why a time-specific volume and the initial flow rate are different quantities.
If the flow estimate has a constant zero error , integration adds to the volume. A stipulated adds 0.080 L over four seconds even if repeated samples of the same biased flow are very precise. Gain errors and timing errors have different effects and need separate checks.
The primary statement describes spirometer calibration verification with a 3-L syringe at multiple flow rates.[ref]
Standardization of Spirometry 2019 Update by Brian L. Graham and others. Calibration and Quality Control, printed p.e75; Table 3
Testing several delivery rates addresses more than matching one number at one speed. It probes whether the measurement system gives compatible integrated volumes across its specified operating conditions. This is measurement calibration and quality assurance, not a diagnosis from a hypothetical flow curve.Graham's documented contribution is the shared technical framework that makes these observations comparable. Instrument response, zero setting, acquisition quality and quantity definitions remain relevant even when a computer performs the integration automatically.
Frederick C. Cobey studies quantitative cardiac imaging, including three-dimensional assessment of how the mitral valve leaflets meet during closure. He is first author of a 2014 primary study using transesophageal echocardiography to measure the valve's coaptation area and relate it to functional mitral regurgitation.[ref]
Quantitative assessment of mitral valve coaptation using three-dimensional transesophageal echocardiography by Frederick C. Cobey and others. Primary byline, affiliations and Abstract
The published name and affiliations establish this contribution without expanding the middle initial.The study examined 25 patients with functional mitral regurgitation undergoing cardiac operations. It used intraoperative two- and three-dimensional echocardiography, followed by offline measurement of the end-systolic coaptation zone and valve area.[ref]
Quantitative assessment of mitral valve coaptation using three-dimensional transesophageal echocardiography by Frederick C. Cobey and others. Abstract, Methods
The three-dimensional observation addresses an extended surface, rather than assuming that a single two-dimensional slice captures its full geometry.The mitral coaptation index divides the measured coaptation zone area by the measured valve area :An original normalization example takes . Valve areas of 6 and then give indices 0.10 and 0.06, respectively. Equal coaptation area need not imply an equal proportion of the valve area. These are stipulated illustrations, not individual patient measurements from the paper.
If every reconstructed length is multiplied by the same scale factor , both areas multiply by and the index is unchanged. The ratio consequently removes that common scale dependence. It does not remove a segmentation error affecting only the coaptation zone, nor does it compensate for measuring a different cardiac phase.
The primary study found an association between the index and the severity of functional mitral regurgitation in its examined sample.[ref]
Quantitative assessment of mitral valve coaptation using three-dimensional transesophageal echocardiography by Frederick C. Cobey and others. Abstract, Results and Conclusions
Cobey's documented work connects an anatomical contact surface to a quantitative imaging observable. Its interpretation still depends on acquisition, surface identification and the population studied.Robert H. Anderson studies cardiac anatomy, including the three-dimensional arrangement of the aortic root and aortic valve. His primary anatomical exposition distinguishes the semilunar leaflet attachments from the anatomical junction between ventricular and arterial walls.[ref]
The surgical anatomy of the aortic root by Robert H. Anderson. Primary byline; Abstract, leaflet attachments and ventriculo-aortic junction
A shared use of the word annulus does not guarantee that two investigators have selected the same structure.The paper describes leaflet attachments extending between basal ventricular positions and the more distal sinutubular region, forming a crown-like arrangement rather than one flat circular line.[ref]
The surgical anatomy of the aortic root by Robert H. Anderson. Abstract, three-dimensional crown and terminology
This makes anatomical terminology part of the measurement definition: diameter, circumference and attachment length require a specified object and plane.An original geometric model illustrates how projection can hide the distinction. Represent a three-lobed closed curve byIts projection onto the horizontal plane is a circle of circumference , independent of . Its actual curve length isFor and , this length exceeds . Identical projected circles can therefore represent spatial curves of different lengths. This is an explanatory mathematical crown, not a fitted human valve or a proposed replacement for anatomical landmarks.
The example shows why documenting the chosen attachment, junction or imaging plane is necessary before comparing dimensions. It does not establish that every aortic measurement must follow this curve. Anderson's contribution is to clarify the structures that those measurements and surgical descriptions intend to represent, keeping a named anatomical boundary distinct from a convenient geometric surrogate.
Ole Storstein is first author of a 1959 experimental study separating airway resistance from lung compliance. The investigators recorded mouth-to-esophageal pressure differences, breathing volume and airflow to analyze the mechanical behavior of respiration.[ref]
Airway Resistance and Lung Compliance by Ole Storstein and others. Primary byline; Methods, simultaneous pressure, volume and airflow recordings
The apparatus used an intra-esophageal balloon, a differential pressure transducer and a pneumotachograph with volume integration. The paper selected corresponding points of no mouth airflow for its compliance calculation and used paired observations during inflation and deflation to estimate resistance.[ref]
Airway Resistance and Lung Compliance by Ole Storstein and others. Methods, Sanborn recording apparatus and definitions of compliance and resistance
Simultaneous signals matter because a pressure observed during flow includes a different mechanical contribution from pressure observed after that flow term vanishes.For an original one-compartment model with a chosen zero-volume baseline, writewhere is lung compliance and is airway resistance. This neglects inertial and regional effects. At stipulated , L, and L/s, the elastic contribution is 4 and the resistive contribution is 1 cm of water. Total modeled pressure is 5 cm of water.
Dividing volume by that total would give , below the chosen compliance. At the same modeled volume and zero flow, pressure becomes 4 cm of water and the ratio recovers 0.10. A time point and the definition of the pressure difference are therefore part of the observable, rather than optional details.
The primary paper explicitly notes the limitation of treating a nonuniform mechanical system as uniform.[ref]
Airway Resistance and Lung Compliance by Ole Storstein and others. Discussion, interpretation of the simplified mechanical analysis
Zero net airflow at the mouth need not establish that every region has identical local behavior. Storstein's documented contribution combines apparatus, simultaneous observations and a stated mechanical interpretation, rather than equating one pressure/volume ratio with every aspect of lung function.Serkan Ünlü investigates cardiac imaging and the dependence of measured heart function on image acquisition. His official institutional profile identifies cardiology as his unit and lists cardiac and cardiovascular research areas.[ref]
Serkan Ünlü academic profile at Gazi University. General Information, institutional unit and research areas
Ünlü is first author of a primary study testing cardiac image foreshortening in echocardiography. The investigators imaged 72 participants using a GE Vivid E9 system and deliberately collected altered apical views from a window one rib-space above the optimal position. They compared ejection fraction and longitudinal deformation measurements using two analysis systems.[ref]
Impact of apical foreshortening on deformation measurements: a report from the EACVI-ASE Strain Standardization Task Force by Serkan Ünlü and others. Byline; Abstract, Methods and results
This is an experimental acquisition comparison: the view changes while the patient's chamber is not assumed to have become anatomically shorter.An original geometric example shows why a constant scale error and a phase-dependent distortion have different consequences. Let a modeled chamber length change from to cm. Its fractional shortening isMultiplying both lengths by 0.9 leaves the ratio unchanged. If instead the measured lengths become 9 and 7 cm because the same 1 cm terminal segment is missed in each phase, the apparent fractional shortening is . Neither model is a complete echocardiography reconstruction; they demonstrate why the error mechanism matters even in a normalized measurement.
The primary study found that deliberately foreshortened views changed measured deformation, with the effect differing by myocardial layer and analysis system.[ref]
Impact of apical foreshortening on deformation measurements: a report from the EACVI-ASE Strain Standardization Task Force by Serkan Ünlü and others. Abstract, Results and Conclusion
Ünlü's documented contribution is to test that dependence experimentally. Repeatable software output does not establish that the acquired image represents the intended anatomical view.S. D. Eilen is the first author of a 1983 study comparing palpation of the apical impulse with two-dimensional echocardiography as evidence of left ventricular enlargement. The investigators examined 41 patients and compared surface observations with end-diastolic volume measurements.[ref]
The study found that impulse location relative to selected chest landmarks alone was not a reliable indicator of increased ventricular volume.[ref]
Accuracy of precordial palpation for detecting increased left ventricular volume by S. D. Eilen and others. Abstract, conclusion about location
Its scientific contribution is a test of a physical sign against an independent imaging measure, rather than an assumption that the visible or palpable position directly reveals chamber size.An original classification example shows why different accuracy quantities must be separated. Imagine 100 subjects, 40 with the target enlargement by an independent reference. A test detects 24 of those 40 and also flags 6 of the remaining 60. Its diagnostic sensitivity is , while the fraction of positive findings confirmed by the reference is . These invented counts are not the 1983 study's data.
The first fraction conditions on the reference-defined group; the second conditions on the observed positive group. Changing which subjects enter a study can change their relationship. The example clarifies why a useful account of a physical sign identifies the observation, comparison measurement and study population. Eilen's published initial-only byline is retained without inferring a full identity or unrelated career history.
Sophia Bäck researches cardiac blood flow using computational fluid dynamics. Her institutional publication profile documents work on personalized atrial-flow models.[ref]
Sophia Bäck publication profile at Linköping University. Research statement and publication list
She is the first author of a primary study that reconstructed left-atrial flow from time-resolved computed tomography and followed modeled particles to distinguish six flow components.[ref]The study compared 21 participants with paroxysmal atrial fibrillation, imaged during sinus rhythm, with eight controls. Its analysis distinguished direct passage, storage and longer-residence histories within the left atrium.[ref]
Comprehensive left atrial flow component analysis reveals abnormal flow patterns in paroxysmal atrial fibrillation by Sophia Bäck and others. Abstract and flow-component definitions
The anatomical images constrain the model, while the trajectories are computational results; they are not direct optical tracking of every blood cell.An original two-region example illustrates the extra information supplied by spatial flow analysis. A chamber with total volume 40 mL and total throughput 20 mL/s has a nominal volume/flow timescale of 2 s. Suppose two idealized parallel regions each contain 20 mL but receive 19 and 1 mL/s. Their individual volume/flow timescales are about 1.05 s and 20 s, despite the unchanged overall volume and throughput.
The example does not predict a clinical threshold. It shows why global chamber volume and cardiac output can coexist with very different local transport histories. Atrial flow component analysis asks which blood passes onward, remains stored or returns through a boundary, adding information to the extrema used for atrial reservoir function. That link between anatomy, flow modelling and transport history is the documented scientific contribution.
R. D. Mosteller authored the 1987 letter Simplified calculation of body-surface area, associated with the Mosteller formula for estimating body surface area from height and mass.[ref]
Simplified calculation of body-surface area by R. D. Mosteller. Primary byline; New England Journal of Medicine 317(17), 1098
The published initial-only identity is retained.The official VA technical manual records the unit-specific equationwhere height is in centimetres and body mass in kilograms.[ref]
Formulas for Body Surface Area Calculator in the VA Clinical Reminders Manager's Manual. Printed p.36, Formulas for Body Surface Area Calculator
It is an empirical estimate of area, not a direct measurement of the skin's complete geometry.For an original arithmetic example, height 180 cm and mass 80 kg give m. Entering 1.8 as though metres were the required input would instead give 0.2 m: a hundredfold change in the numerical height becomes a tenfold change after taking the square root. The unit convention is therefore part of the formula, not an optional label.
A small-error calculation givesThis describes sensitivity to input errors within the equation; it does not quantify the empirical model's accuracy for a particular person. Area estimates can also enter derived quantities such as cardiac index, defined as cardiac output divided by body surface area. For stipulated output 5 L/min and area 2 m, that ratio is 2.5 L/(min m). A normalization changes the stated quantity; it does not create an additional direct flow measurement.
S. G. Parker is the first named author of the 1983 primary study of optical radiation passing through human nails, coauthored with Brian Diffey. The byline uses these initials. The study measured total transmission through thirteen autopsy toenails at fifteen wavelengths from 300 to 600 nm and reported decreasing transmission towards the shorter wavelengths.[ref]
The transmission of optical radiation through human nails by S. G. Parker and B. L. Diffey. Abstract and primary byline; British Journal of Dermatology 108, 11–16 (1983)
The apparatus joined a monochromator to an integrating sphere and photodiode. Selecting an illumination wavelength and collecting the light that emerges answer different experimental questions. In particular, light scattering can redirect transmitted light outside a narrow detector acceptance angle without absorbing it. The collection geometry must therefore accompany a stated transmittance.
Collection geometry in nail-transmission measurements can be illustrated with an original accounting model. Let be directly transmitted fraction, the remaining transmitted fraction, and the fraction of diffuse transmission collected by a particular detector. Its idealized response isFor stipulated direct and diffuse fractions of 0.04 and 0.08, total transmission is 0.12. A detector collecting one quarter of the diffuse component gives . The sample has not changed; the reported value changes because the collection differs. An integrating sphere is designed to collect light over many directions, although its ports, calibration and losses still matter.
An isolated nail plate experiment also separates plate transmission from the optical behaviour of living tissue underneath. These measurements do not by themselves determine nail-bed blood flow or the response of every living nail. The work offers a concrete example of defining the specimen, wavelength and detector collection before interpreting an anatomical covering as an optical filter.
J. R. Ortale is the first named author of a primary anatomical study of the coronary sinus and its tributary veins. The paper's byline uses these initials. Ortale and colleagues dissected 37 formalin-fixed adult human hearts, recording venous connections and relationships between veins and arteries.[ref]
The anatomy of the coronary sinus and its tributaries by J. R. Ortale and others. Byline and Abstract; Surgical and Radiologic Anatomy 23, 15–21 (2001), DOI 10.1007/s00276-001-0015-0
The observations make anatomical variation concrete. The small cardiac vein was present in 54% of examined specimens, and a connection of approximately 1 mm calibre between anterior and posterior interventricular veins was found in 19%. These are specimen observations, not universal drawings of one invariant venous arrangement.[ref]
The anatomy of the coronary sinus and its tributaries by J. R. Ortale and others. Abstract, venous presence and anastomosis observations
An artery's familiar route does not uniquely determine the course of an adjacent vein.Sampling limits in anatomical variant frequencies distinguish an observed absence from a universal absence. In an original hypothetical example, suppose a different variant is seen zero times in 37 independent, representative specimens. Under a binomial distribution model, a population frequency gives probability of that observation. Solving gives : even zero observed cases would be compatible with a one-sided 95% upper bound near 7.8% under those assumptions. This hypothetical calculation is not a result reported in Ortale's paper, and its sampling assumptions need justification.
Dissection establishes visible structural relationships in preserved specimens. It does not directly measure living blood flow, pressure or whether a particular connection carries a substantial flow under a given condition. The study's value is therefore both anatomical and methodological: document what was observed, distinguish prevalence in the specimen set from a population claim, and keep structural evidence separate from a physiological flow measurement.
A. P. Shepherd is the first named coauthor of a 1989 instrument paper that separated hemoglobin concentration from oxygen saturation in a sample of whole blood. The published byline uses these initials. The apparatus illuminated a blood-filled capillary tube with red and infrared light-emitting diodes; scattered light travelled along the tube to a photodetector, followed by amplification, digitization and microprocessor calculation.[ref]
An oximeter for measuring hemoglobin concentration and oxygen content by A. P. Shepherd and others. Abstract and byline, American Journal of Physiology 257, H1705–H1711, DOI 10.1152/ajpheart.1989.257.5.H1705
The important distinction is hemoglobin-concentration and saturation separation. Oxygen saturation measures the fraction of available hemoglobin oxygen-binding capacity that is occupied. In a simplified accounting model, the amount of oxygen bound to hemoglobin per unit blood volume is , where is hemoglobin mass concentration, is fractional oxygen saturation and is oxygen-binding capacity per unit hemoglobin mass. At the same , stipulated concentrations of and therefore give a twofold difference in bound oxygen content. The example omits dissolved oxygen and illustrates why oxygen saturation alone cannot determine the oxygen carried per unit blood volume.
The paper's instrument calibration addressed this separation optically: the microprocessor used a nonlinear function of infrared intensity for total hemoglobin concentration and a ratio of logarithms of red and infrared intensities for oxygen saturation. Those are distinct calibrated transformations of the detector signals; a two-colour reading is not automatically a concentration-independent saturation measurement.[ref]
An oximeter for measuring hemoglobin concentration and oxygen content by A. P. Shepherd and others. Abstract: infrared concentration function, logarithmic intensity ratio and concentration-related calibration shifts
Wilbert Aarnoudse is the named first author of a 2007 study validating direct volumetric blood flow measurement in coronary arteries by thermodilution. The method used continuous saline infusion, a 2.8-F infusion catheter and a 0.014-inch pressure/temperature-sensing guidewire. Validation included five dogs and 35 patients.[ref]
The measurement uses a thermal tracer: a known inflow at a different temperature changes the downstream mixture temperature. An original two-stream model illustrates the principle. If blood and infused fluid have equal volumetric heat capacities, negligible heat exchange with the vessel and complete mixing,Here are volume flow rates, is baseline blood temperature, the infused-fluid temperature and the mixed temperature. This conservation calculation is not the clinical instrument's full calibration model.
For stipulated model inputs mL/min, , and , the inferred blood flow is 230 mL/min. A small downstream temperature difference can therefore encode a larger flow, while also making the result sensitive to temperature offsets and incomplete mixing. Coronary thermodilution mixing assumptions matter independently of the precision of the temperature readout.
The primary study reports a canine comparison regression mL/min with .[ref]
Direct volumetric blood flow measurement in coronary arteries by thermodilution by Wilbert Aarnoudse and others. Abstract, Results
Association, calibration agreement and repeatability are different properties: a high association does not force slope one and intercept zero. The apparatus and validation comparisons make the credited work a measurement-method contribution, rather than a direct measurement of blood oxygen content or a general substitute for every coronary assessment.Christie D. Fowler is a neuroscientist whose experimental work includes the role of nicotinic acetylcholine receptors in controlling nicotine intake. In a 2011 study, mice lacking the receptor subunit consumed more nicotine; restoring the subunit in the medial habenula corrected this phenotype. Reducing the subunit locally in rats produced a corresponding change in intake.[ref]
Habenular α5 nicotinic receptor subunit signalling controls nicotine intake by Christie D. Fowler and others. Abstract and Figures 1–3; author contributions identify Fowler's roles in experimental design, experiments, analysis and writing.
The combination of gene knockout and localized genetic rescue provides an illuminating experimental comparison: deleting a component throughout an animal shows that it matters, while restoring it in one brain region helps locate a sufficient site of action for the measured phenotype. The rat experiments further distinguished nicotine's rewarding effects from the inhibitory effects of higher doses. Loss of the latter signal helped explain increased intake; the result cannot simply be summarized as an increase in reward at every dose.[ref]
Habenular α5 nicotinic receptor subunit signalling controls nicotine intake by Christie D. Fowler and others. Figures 2–3: rescue and comparison of reward-enhancing versus reward-inhibiting effects.
C. Mulle is the first author of a 1998 study testing the contribution of a kainate receptor subunit to signalling in the hippocampus. The investigators compared mice lacking the subunit with controls and measured responses in CA3 neurons.[ref]
Altered synaptic physiology and reduced susceptibility to kainate-induced seizures in GluR6-deficient mice by C. Mulle and others. Original byline and Abstract: receptor-subunit deletion
The deletion reduced sensitivity to kainic acid and removed a postsynaptic component evoked by repeated stimulation of the relevant inputs. The mutant mice also showed reduced susceptibility to the experimentally induced seizures.[ref]
Altered synaptic physiology and reduced susceptibility to kainate-induced seizures in GluR6-deficient mice by C. Mulle and others. Abstract: synaptic recordings and systemic-kainate comparison
A molecular perturbation was therefore connected to both a local physiological readout and a whole-animal response. The latter alone would not localize the changed signalling step; the neuron recordings supplied that additional resolution. The result concerns the tested genetic and experimental conditions, rather than showing that every kind of seizure uses the same mechanism.
J. L. Weller coauthored, with D. C. Klein, a 1970 investigation of circadian rhythms in the rat pineal gland. The experiment measured serotonin N-acetyltransferase activity over time rather than inferring all biochemical events from the final amount of melatonin.[ref]
Night-time activity exceeded daytime activity by more than fifteenfold. Persistence in darkness and in blinded animals, together with suppression by constant light, supplied controls on how the rhythm related to environmental illumination.[ref]
An enzyme-activity measurement asks what a preparation can do under the assay conditions. It is different from measuring how much enzyme is present or how much product has accumulated in an intact animal. That distinction makes the work an example of connecting a daily biological pattern to a defined biochemical readout.
D. C. Klein coauthored a 1970 study connecting a circadian rhythm to the activity of serotonin N-acetyltransferase in the rat pineal gland. With J. L. Weller, D. C. Klein found activity more than fifteen times higher at night than during the day.[ref]
The rhythm persisted in complete darkness and in blinded animals, while constant illumination suppressed it. These comparisons distinguished an internally maintained rhythm from a response requiring the eye to detect each transition between day and night.[ref]
The study also tested regulation in isolated preparations: norepinephrine, rather than serotonin, regulated the measured activity under those conditions. Combining the time course with an intervention on the biochemical system connected timing to a particular step associated with melatonin synthesis.[ref]
Indole metabolism in the pineal gland: a circadian rhythm in N-acetyltransferase by D. C. Klein and J. L. Weller. Abstract: in-vitro regulation and relation to melatonin rhythm
M. Masu is the first author of a 1995 experiment testing the role of mGluR6 in retinal signalling. The team generated mice lacking this glutamate receptor and compared responses to the onset and offset of light.[ref]
The gene knockout removed the measured ON response while leaving the OFF response intact. Gross retinal organization and optic projections showed no obvious changes, and light-conditioned avoidance behaviour remained.[ref]
Specific deficit of the ON response in visual transmission by targeted disruption of the mGluR6 gene by M. Masu and others. Abstract: electrophysiological, anatomical and behavioural comparisons
These comparisons distinguish failure of a specific signalling route from total loss of vision. A preserved-looking layer of neurons need not transmit signals normally; conversely, a defect in ON retinal bipolar cells need not eliminate information carried by the OFF pathway. The initial-only byline is retained without inferring additional biographical details.
M. Imai authored a 1977 study comparing bumetanide and furosemide in isolated thick ascending limbs of rabbit and rat kidneys. Perfusing the isolated renal tubules allowed direct effects on the epithelium to be studied apart from whole-animal changes in circulation or hormone output.[ref]
Applying the compounds inside the tubule reversibly reduced the lumen-positive electric potential difference. Bumetanide also reduced the outward movement of labelled chloride; the dose-response comparison found greater potency than furosemide under the tested conditions.[ref]
Effect of bumetanide and furosemide on the thick ascending limb of Henle's loop of rabbits and rats perfused in vitro by M. Imai. Abstract: luminal application, chloride tracer and dose-response observations
Pairing electrical and tracer measurements matters. An electric potential difference is a collective result of ion transport; tracking labelled chloride adds a chemically specific readout. Reversibility after changing the perfusate helps distinguish an acute transport effect from permanent destruction of the preparation.
E. E. Fesenko is the first author of a 1985 experiment showing that cyclic guanosine monophosphate can directly increase electrical conductance in membrane patches from rod cells. The original publisher gives the byline Evgeniy E. Fesenko; the initial-only article title is retained.[ref]
The investigators excised inside-out membrane patches and applied cyclic guanosine monophosphate to the exposed inner face. Conductance increased reversibly even without nucleoside triphosphates, arguing against a requirement for an intervening phosphorylation reaction in that preparation. Related tested nucleotides did not reproduce the effect.[ref]
Induction by cyclic GMP of cationic conductance in plasma membrane of retinal rod outer segment by E. E. Fesenko and others. Abstract: patch orientation, reversibility and specificity controls
Excising a patch simplified the experiment: an electrical response could be tested without the entire photoreceptor remaining intact. It supported a membrane-local action of the signal, while leaving the complete light-response sequence in a living rod cell as a further question.
Catherine W. Morgans studies signalling between photoreceptors and retinal bipolar cells. A 2009 study led by Catherine W. Morgans connected TRPM1 to the depolarizing response controlled by mGluR6 in ON retinal bipolar cells.[ref]
The team compared expression, localization and function. Mice lacking TRPM1 retained the photoreceptor-associated a-wave recorded by electroretinography but lacked the bipolar-cell-associated b-wave. Patch clamp recordings from retinal slices then tested individual retinal bipolar cells, rather than inferring their behaviour from the summed retinal signal alone.[ref]
TRPM1 is required for the depolarizing light response in retinal ON-bipolar cells by Catherine W. Morgans and others. Figures 3–4: electroretinography and whole-cell recordings
That combination illustrates how a molecular candidate becomes a functional explanation: localization establishes where a protein is found, whereas removing it and recording a changed current tests its contribution to signalling.
Selig Hecht was a researcher in the physiology of vision who measured how sensitivity changes during light adaptation and dark adaptation. In a 1937 study, Selig Hecht and colleagues varied prior illumination and then measured recovery of the human eye's ability to detect faint test lights.[ref]
The influence of light adaptation on subsequent dark adaptation of the eye by Selig Hecht and others. Original byline and Abstract: preadaptation and recovery measurements
The recovery curve depended on the preceding exposure. Under sufficiently bright preadaptation, an early phase associated with cone cells was followed by a slower phase associated with rod cells; other exposure conditions did not reveal both phases in the same way.[ref]
This makes prior conditions part of the experiment. Two observers tested after the same time in darkness need not be in comparable states if their preceding illumination differed. A curve measured over time reveals changes that a single final sensitivity measurement would hide. The historical illumination unit called photons in this paper should not be interpreted as a count of individually detected photons.
R. Nahum is the first author of a 1995 study of hormone regulation in human theca cells. The investigators maintained the cells in serum-free culture and measured androstenedione after four days, testing insulin and related growth signals with and without luteinizing hormone.[ref]
Metabolic regulation of androgen production by human thecal cells in vitro by R. Nahum and others. Abstract: culture design, treatment comparisons and androstenedione assay; Human Reproduction 10, 75–81, 1995
Hormone output increased under the tested conditions without a corresponding stimulation of cell growth. That distinction matters when interpreting a culture assay: more product can reflect changed activity of the cells already present, rather than simply a larger population. The experiment identified regulation of androgen production in this cultured system; it did not by itself establish how the same intervention would behave in a whole person.[ref]
Metabolic regulation of androgen production by human thecal cells in vitro by R. Nahum and others. Abstract: increased steroid production without stimulated thecal-cell growth
T. A. Fitz is the first author of a 1982 study distinguishing two steroid-producing cell populations in the sheep corpus luteum. The researchers separated small and large luteal cells before measuring progesterone secretion and responses to stimulating substances. Comparing separated populations allowed a tissue-level output to be related to its cellular components.[ref]
Characterization of Two Steroidogenic Cell Types in the Ovine Corpus Luteum by T. A. Fitz and others. Abstract: separation of dispersed ovine luteal cells and secretion/binding assays; Biology of Reproduction 27, 703–711, 1982
Without stimulation, equal numbers of large luteal cells released about 20 times as much progesterone as the small-cell population. The equal-count comparison is essential: a higher total secretion could otherwise arise merely because one preparation contained more cells. It also explains why a change in the mixture of cell types can alter total tissue secretion even when each population's individual behavior stays unchanged.[ref]
Characterization of Two Steroidogenic Cell Types in the Ovine Corpus Luteum by T. A. Fitz and others. Abstract: basal secretion normalized to equal cell numbers
B. K. Fung is the first author of a 1981 study identifying transducin as an amplified intermediary in visual signaling. The team characterized its three types of protein subunits and reconstructed membrane preparations containing rhodopsin and transducin. Illumination promoted binding of a stable GTP analogue even when the downstream phosphodiesterase was absent.[ref]
Flow of information in the light-triggered cyclic nucleotide cascade of vision by B. K. Fung and others. Abstract: subunit characterization and reconstituted membranes; PNAS 78, 152–156, 1981
The researchers then isolated the analogue-bound alpha subunit and found that it activated phosphodiesterase on unilluminated membranes. Separating and recombining components helped establish order: rhodopsin activates transducin, which can activate the enzyme acting on cyclic guanosine monophosphate. A downstream response after adding an isolated intermediary is stronger evidence of a signaling connection than the mere coexistence of the components.[ref]
Flow of information in the light-triggered cyclic nucleotide cascade of vision by B. K. Fung and others. Abstract: nucleotide binding on the alpha subunit and activation without illumination
Evren C. Tumer is a researcher whose work with Michael S. Brainard tested how small variations in a practiced skill can support further motor learning. Their 2007 study examined adult Bengalese finch song, which is highly repeatable but still varies slightly between performances. They asked whether this variation was merely unavoidable noise or could provide alternatives from which learning selects.[ref]
Performance variability enables adaptive plasticity of crystallized adult birdsong by Evren C. Tumer and Michael S. Brainard. Abstract and author byline; Nature 450, 1240–1244, 2007
A computerized system measured the pitch of selected song elements and delivered an auditory disruption for only some of the naturally occurring variations. The birds shifted pitch to avoid the disruption, with changes restricted to the targeted features. The experiment therefore linked a measurable action, its outcome and a later change in performance. It showed that a stable adult skill can contain useful variation on which adaptive motor learning operates.[ref]
Performance variability enables adaptive plasticity of crystallized adult birdsong by Evren C. Tumer and Michael S. Brainard. Abstract and Figures 1–4: contingent feedback, targeted changes and timing controls
J. Tapanainen is the first author of a 1991 study of steroid production in cultured human granulosa-lutein cells. The team compared 48-hour cultures with and without human chorionic gonadotropin or follicle-stimulating hormone, measuring several steroids and assaying aromatase activity separately.[ref]
Regulation of steroid and steroid sulfate production and aromatase activity in cultured human granulosa-luteal cells by J. Tapanainen and others. Abstract: culture design and measured endpoints
Both hormones increased pregnenolone and progesterone production substantially, while changes in several other steroid products were small. This illustrates why one hormone measurement cannot summarize a whole biochemical pathway: different reaction steps can impose different constraints. Separate measurements of products and enzyme activity make the proposed regulation experimentally testable, while the cultured-cell result remains distinct from a complete account of ovarian function in an animal.[ref]
Regulation of steroid and steroid sulfate production and aromatase activity in cultured human granulosa-luteal cells by J. Tapanainen and others. Abstract: differential steroid responses and aromatase regulation; Journal of Steroid Biochemistry and Molecular Biology 39, 19–25, 1991
Barry M. Brenner was a researcher in kidney physiology who helped make the physical forces driving glomerular filtration directly accessible to experiment. In 1971, Barry M. Brenner and collaborators studied rats whose glomeruli lay at the exposed surface of the kidney. This anatomical feature let them place pressure-measuring micropipettes inside glomerular capillaries, rather than infer their pressure only from upstream arterial measurements.[ref]
The Dynamics of Glomerular Ultrafiltration in the Rat by Barry M. Brenner and others. Byline and Abstract: surface-glomerulus Wistar rats and servo-nulling micropipette transducers
The team combined hydrostatic pressure measurements with oncotic pressure estimates and measurements of filtration by individual nephrons. These quantities describe different parts of the mechanism: a pressure difference can drive water across the glomerular filtration barrier, while the concentration of retained plasma proteins opposes that movement. Raising pressure in the receiving compartment can therefore reduce filtration without changing arterial pressure. Connecting these separately measurable quantities made the experiment a test of a physical explanation of kidney function.[ref]
The Dynamics of Glomerular Ultrafiltration in the Rat by Barry M. Brenner and others. Abstract: proximal-tubular pressures, plasma colloid-osmotic pressures and single-nephron filtration; qualitative conclusions only, in view of the linked October 1971 correction
G. Gamba is the first author of a 1994 study identifying two related salt-transport proteins in the mammalian kidney. The team cloned the corresponding DNA sequences and tested the expressed proteins in Xenopus laevis oocytes. One transported sodium, potassium and chloride; the other transported sodium and chloride without the same potassium requirement.[ref]
Molecular cloning, primary structure, and characterization of two members of the mammalian electroneutral sodium-(potassium)-chloride cotransporter family expressed in kidney by G. Gamba and others. Abstract: cloned cDNAs and functional expression; Journal of Biological Chemistry 269, 17713–17722, 1994
The transporters also differed in their responses to inhibitors, including bumetanide. Combining sequence comparison, transport assays and localization within the kidney established a family resemblance without assuming identical function. This is an important experimental distinction: a similar protein primary structure suggests a relationship, while controlled measurements of ion movement test what each membrane transport protein actually does.[ref]
Molecular cloning, primary structure, and characterization of two members of the mammalian electroneutral sodium-(potassium)-chloride cotransporter family expressed in kidney by G. Gamba and others. Abstract: sequence similarity, differing ion requirements and inhibitor sensitivity, and intrarenal expression
Articles were limited to the first 100 out of 262 total.
Articles by others on the same topic
There are currently no matching articles.

