Similar triangle Created 2026-10-14 Updated 2026-10-20
Two triangles are similar if a Euclidean similarity maps one onto the other. Their corresponding angles agree, and corresponding side lengths have a common positive ratio.
Specify the correspondence first: matches , matches and matches . For similar triangles, the common scale factor satisfies
The ratios compare matching sides in the same order. A Euclidean similarity can also move, turn or reflect the triangle; its orientation on the page is irrelevant. In the Euclidean plane, matching just two interior angles is enough: their sums force the third to match, and equal corresponding angles force the side ratios to agree. This is the angle-angle (AA) criterion for similar triangles. Matching just one angle is insufficient.
Scale the right triangle with vertices , and by . Its new vertices are , and , and its side lengths are . The matching side ratios are . Both triangles have a right angle and the same two other interior angles, approximately and . However, their areas are and : doubling lengths multiplies area by four.
Figure 1.
Similar 3-4-5 and 6-8-10 right triangles: side lengths multiply by , while area multiplies by
. Details.
Generally, a Euclidean similarity multiplies both a base and its perpendicular height by , so the area becomes . This explains why an enlarged drawing needs four times as much surface when each length doubles. It also enables indirect measurement: under assumptions of level ground, vertical objects and parallel light rays, an object of height casting a shadow of length provides a right triangle. Another object's shadow of length gives a similar triangle and height . The shared angles justify the inference; visual resemblance alone does not.
Euclid's Elements VI, Definition 1 describes similarity using corresponding angles and proportional sides. VI.4 establishes the implication from matching angles to matching side ratios, while VI.19 states the squared relation between side ratios and areas. These are documented ancient formulations of the principles used above, without establishing a first discoverer.[ref][ref][ref]
A timing-skew bound for a ratiometric measurement limits the resistance-ratio error caused by sampling the signal and reference at different times. It converts a bound on the fractional rate of change of the shared excitation into an acquisition-timing requirement. This is useful even when the two analog filters are exactly matched.
Use the model in sampling skew after matched ratiometric filters: the common filtered excitation is , the true resistance ratio is , and the reference is sampled after the signal. Then . Suppose is continuously differentiable and its logarithmic derivative obeys throughout the entire interval between the samples. The fundamental theorem of calculus gives
The same proof works for either sign of . Writing , exponentiation yields the exact interval
This is a deterministic bound under the stated slope assumption, rather than an expansion truncated at first order.
For an original timing budget, suppose and require at most fractional resistance error from skew alone. It suffices to require
The slightly smaller-than- value accounts for the exponential upper bound. An excitation proportional to reaches one side of the logarithmic bound exactly, so the bound is attainable in this model.
A sufficient way to establish is to verify and , giving . A filter cutoff by itself supplies neither a positive excitation floor nor this fractional-slope bound. Near an excitation zero, a small absolute change can produce a large resistance-ratio error. The primary filter-design report establishes the need to match signal and reference dynamics and to allow filter settling; the inequality above adds an original unequal-time error budget.[ref]
A proposed bench check uses a stable sensor substitute and reference resistor, records the filtered excitation with an oscilloscope, and deliberately changes the acquisition delay. Compare each observed ratio with the interval predicted from a verified excitation floor and slope bound. This isolates timing effects from a fixed reference-resistor error in ratiometric resistance measurement.
Trigonometric function Created 2026-09-24 Updated 2026-10-13
Trigonometric functions turn an angle into a coordinate or a ratio of lengths. Start at on the unit circle and rotate counterclockwise through radians: the resulting point is
The cosine records horizontal position and the sine records vertical position. This definition continues around the whole circle, including negative angles, so the signs encode direction rather than requiring a separate rule for each right triangle.
Figure 1.
Sine and cosine as signed circle coordinates and periodic traces
. Details.
The unit circle picture explains why these functions are useful beyond measuring triangles. The two coordinates of a point rotating at constant angular speed are periodic functions. Scaling the radius to and using gives and . A circular motion becomes two simple repeating traces, connecting Euclidean geometry, simple harmonic motion, and Fourier series.
For an acute angle in a right triangle, rescaling its hypotenuse to one recovers the familiar ratios: sine is opposite side divided by hypotenuse, and cosine is adjacent side divided by hypotenuse. The tangent function is their ratio, , wherever the denominator is nonzero; the secant function, cosecant, and cotangent give the other reciprocal ratios.
The same names extend to complex numbers through the complex exponential:
These definitions agree with the circle interpretation for real angles. For complex arguments, the values need not lie between and ; the literal circle-coordinate picture is restricted to real arguments. [ref]
For fixed nonnegative integer , the row increases to its middle and then decreases. Indeed, for , the ratio of consecutive binomial coefficients is , which is greater than, equal to, or less than according as is less than, equal to, or greater than . Thus even has one maximum at , while odd has two equal maxima at .
Total-protein Western blot normalization compares a target-band signal with a signal representing many transferred proteins in that lane. It is distinct from measuring one reference protein, and from measuring the target itself. Its denominator is a loading proxy: normalization estimates target abundance relative to detected total protein, rather than target amount per biological cell. Different sample compositions, selective Western blot transfer losses or unequal stain responses can still matter.
For an original calculation, suppose background-corrected target signals , and total-protein signals , are in their respective proportional response ranges. Then
The invented signals double together, so this calculation supplies no evidence for a higher target fraction. With but , the same calculation gives . These examples assume a common target response and a common total-protein response between lanes, negligible remaining background, and comparable target recovery; they do not equate total-protein staining with target abundance. Multiplying both signals in a lane by the same loading factor cancels in their ratio; a selective target loss does not cancel.
Western blot response saturation means that increasing target amount no longer increases the recorded signal proportionally. It can arise before imaging, through limited binding or reagent availability, as well as through detector limits. Shortening exposure can address a detector limit without repairing an already unresponsive assay. Test the target and normalization readouts with a dilution series under the actual assay conditions; merely seeing a gray band does not establish a proportional response.
In a 2013 methods experiment, a biological cell extract containing added purified yeast protein was separated on gels, transferred with a Trans-Blot Turbo to polymer membranes, and read with an enzyme-linked secondary antibody. A ChemiDoc MP imager and film recorded the same dilution-series blots. The target and an abundant reference protein had different usable response ranges; transferred total-protein imaging and the reference bands did not track loading equally well. This demonstrates the need for assay-specific response checks, rather than a universal conversion from darkness to amount. [ref]
An illustrative response model separates background , target amount , retained fraction , response scale and characteristic amount :
This is an assumed model, not a fitted Western blot calibration. When , . When , approaches . For two otherwise identical lanes, doubling gives the background-corrected ratio
At the ratio is , despite a true twofold amount change. Thus Western blot normalization cannot recover a lost amount difference merely by dividing two saturated readouts.