John E. Tanner 2026-11-05
John E. Tanner was a physical chemistry researcher whose work with Edward O. Stejskal established pulsed field gradient NMR as a method for measuring self-diffusion. He studied physical chemistry at Oberlin, Indiana and Wisconsin, and later worked at Idaho National Laboratory. His early NMR work received renewed recognition with an honorary fellowship in 2016.[ref]
Figure 1.
John E. Tanner, from the profile portrait accompanying his family memorial
.
The appeal of pulsed field gradient NMR was practical as well as theoretical: strong magnetic field gradients could encode motion without remaining strong during excitation or detection. In a 2017 interview with Derek Jones, Tanner recalled choosing Stejskal's laboratory because it had a magnet and because he wanted to measure slow diffusion. He also described rebuilding the probe to deal with eddy currents generated by switching the magnetic field gradients.[ref]
Tanner made restricted diffusion experimentally concrete. He described assembling 99 layers of mica with aluminium foil spacers, carefully removing wrinkles and burrs to obtain regular gaps. Such a controlled geometry lets an echo probe displacement between known barriers, rather than treating every loss of NMR signal as free diffusion with a smaller diffusion coefficient.[ref]
His 1970 work used a stimulated echo to extend the observation interval when spin-lattice relaxation is slower than transverse relaxation. The interval can store the relevant pattern as longitudinal magnetization, rather than keeping it transverse throughout.[ref] For an illustrative ideal comparison, take , and storage time . The storage-dependent nuclear spin relaxation factors are and . Even allowing the ideal three-pulse pathway's initial factor of , the former factor is about 45 times larger. This compares only that storage contribution: pulse losses, the other transverse intervals and diffusion attenuation still matter.[ref]
Restricted diffusion 2026-11-05
Restricted diffusion is diffusion whose displacement statistics are constrained by boundaries that particles cannot cross. A reflecting boundary condition models an impermeable wall: particles continue moving, but there is no normal diffusive flux through it. Finite permeability would require a different boundary model.
A physical demonstration uses a liquid confined between solid lamellae. In his first-person account, John E. Tanner described constructing 99 mica layers separated by aluminium-foil strips, removing wrinkles and burrs to obtain regular spacing; Edward O. Stejskal inspected the stack with a stereomicroscope. Pulsed magnetic-field gradients encode displacements in the nuclear magnetic resonance signal, allowing motion normal to the barriers to be compared with less confined directions.[ref] This is a material confinement experiment, not a change in the liquid's chemistry.
For an original one-dimensional model, let particles diffuse in with constant diffusion coefficient :
The wall conditions are homogeneous Neumann boundary conditions for the diffusion equation. Start in equilibrium, so has the uniform distribution on . Its variance is
At long time separation, the positions decorrelate. Consequently the mean squared displacement approaches
At short times relative to , most displacements have not encountered a wall, and the leading scale is the free-diffusion result . For a hypothetical gap , the long-time plateau is and its root is about .
Figure 1.
Equilibrium restricted diffusion saturates in a reflecting interval
. Original Neumann-eigenmode calculation with uniform initial positions; time is and mean squared displacement is divided by . Perfectly reflecting walls give a plateau , while free diffusion continues as . These are model curves, not measurements of the mica stack. Details.
The initial condition matters: fixing instead gives the long-time value . Likewise, echo attenuation in a confined sample must not automatically be converted into a free-diffusion coefficient. Confinement geometry, timing and the selected boundary model all affect the inference.
Stejskal-Tanner equation 2026-11-05
The Stejskal-Tanner equation relates diffusion-sensitive echo attenuation to a rectangular gradient-pair experiment:
It assumes free Gaussian diffusion with a constant scalar diffusion coefficient , ideal refocusing and two equal nonoverlapping rectangular gradient pulses of magnitude and duration , whose starting times are separated by . The gyromagnetic ratio is angular. The baseline is an otherwise matched echo without the applied diffusion-encoding gradients. These definitions are part of the formula, rather than optional choices of notation.[ref]
The finite-duration term follows directly from the encoding history. Write . The effective encoding rises linearly from zero to , stays constant for , then falls linearly to zero. Each ramp contributes to the diffusion weighting b-value, so
The two physical gradients can have the same polarity: the intervening pulse reverses the effective phase-encoding sign.
Figure 1.
Reused original illustration of a refocused gradient pair and its accumulated encoding
. The chosen illustrative timings are not a reconstruction of a historical run. Both physical gradient pulses have the same sign; refocusing reverses their effective encoding sign. Squaring the lower trace and integrating gives the finite-duration correction. Details.
For the illustrated and , the normalized integral is , rather than . This isolates the pulse-duration correction without assigning an unmeasured gradient amplitude.
The 1965 work combined theory with apparatus tests, including slow self-diffusion in dry glycerol.[ref] Restricted diffusion, flow, background gradients and measurement noise require their own interpretation; fitting a single attenuation to this equation does not establish all of its assumptions.