Daniel Axelrod Created 2026-10-24 Updated 2026-11-05
Biophysicist who used total internal reflection fluorescence microscopy to illuminate cell–surface contacts. Excitation near an interface connected optical confinement with selective observation of material close to a supporting surface.[ref]
A pyrene-actin assay can follow assembly continuously. A small labelled fraction mixed with otherwise unlabelled actin gives an increasing signal as the labelled subunits enter actin filaments, allowing comparison of lag, growth and plateau. Drug-only and labelled-monomer controls are essential because ToxB might alter fluorescence directly; comparable label incorporation and a polymer-mass calibration are needed to compare wild-type and mutant actin. An institutional description explains this polymerization-dependent fluorescence readout.[ref]
Direct single-filament imaging by total internal reflection fluorescence microscopy can separately measure actin filament appearance, elongation and shortening, rather than inferring all three from bulk polymer mass. It requires matched surface and label conditions, since immobilization can perturb assembly. light scattering or turbidity can also follow assembly, but aggregates and changes in actin filament length or bundling complicate mass estimates. electron microscopy can verify actin filament morphology and length at selected times, although sampling and preparation make it less convenient for a continuous kinetic curve. Combining a bulk assay with direct actin filament imaging addresses different ambiguities.
Past exam of the biological physics course of the University of Oxford 2019 6 iii Solution 2026-10-25
Fluorescence localization precision can be much finer than the image width: a fluorescent molecule produces a diffraction-broadened point spread function, but the centre of that distribution can be estimated much more precisely than its width. Fit the measured camera counts to a calibrated point-spread model with position, brightness and background parameters. For an ideal Gaussian image of standard deviation and independent detected photons, the centroid precision scales asPixelation and background worsen this limit. A useful approximate variance for square pixels of width and background rms noise photons per pixel isThis estimate requires a correctly specified isolated image and appropriate noise model. Drift, optical aberration, dye motion, linkage offset, bleaching and motion blur introduce further errors; localization precision alone does not guarantee absolute positional accuracy.[ref]
Precise nanometer localization analysis for individual fluorescent probes by Russell E. Thompson and others. Photon number, pixel size and background dependence of localization uncertainty
In the Myosin V measurements, total internal reflection fluorescence microscopy reduced background and a two-dimensional Gaussian fit localized a single dye attached to a light chain with roughly precision. The motor's centre advances about per cycle. A hand-over-hand mechanism instead moves the rear head about past the stationary front head, exchanging their roles. A label displaced by from the midpoint therefore gives alternating displacements and nm; near a head this tends towards alternating and nm. An inchworm model would give approximately uniform nm label displacements. Resolved unequal alternating steps therefore distinguish the mechanisms, with interpretation depending on the label geometry.[ref]
Myosin V Walks Hand-Over-Hand: Single Fluorophore Imaging with 1.5-nm Localization by Ahmet Yildiz and others. Single-light-chain fluorophore localization, alternating displacements and hand-over-hand interpretation; Science 300, 2061–2065 (2003)
For sub-diffraction imaging, arrange that only a sparse, spatially separable subset of fluorophores emits in each frame, localize those emitters, then combine many frames into a map. Photoactivation or reversible stochastic switching provides the sparse subsets. Distinct nearby molecules can then be localized at different times, circumventing overlap of their simultaneously emitted diffraction patterns. The achievable structural resolution depends on photon-limited precision, label density and linkage, repeated blinking, drift correction and specimen motion; arbitrarily many fits to the same dye do not supply missing labels elsewhere. This is the principle behind PALM and STORM, with their different switching strategies.[ref]
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM) by Michael J. Rust and others. Sequential sparse activation and localization of fluorophores to reconstruct a super-resolution image
Protein subunit 2026-11-05
A protein subunit is an individual polypeptide component of a protein complex. The number of protein subunits counts chain copies, whereas the number of subunit types counts distinct kinds of chain. An assembly has four protein subunits of two types. A protein domain is a region within a chain and need not be a separate protein subunit; the arrangement of several chains belongs to protein quaternary structure.
The alpha/beta tubulin heterodimer illustrates the distinction: it contains two related but different polypeptides, not two domains cut out of one chain. The 1998 electron-crystallographic model resolved the alpha/beta architecture at angstrom resolution, using zinc-induced tubulin sheets.[ref]
Structure of the alpha beta tubulin dimer by E. Nogales and others. Abstract and PDB entry 1TUB: distinct alpha and beta chains and electron-crystallographic method.
Subunit counting can also become an optical experiment. In total internal reflection fluorescence microscopy, tagged membrane proteins can be observed as isolated fluorescent spots; successive photobleaching steps reveal individual fluorescent tags disappearing. Subunit counting in membrane-bound proteins by Maximilian H. Ulbrich and Ehud Y. Isacoff used this approach on membrane proteins expressed in frog oocytes. For NR1/NR3B receptor assemblies, tagging one component type mainly gave two steps, while tagging both gave four, supporting a two-plus-two arrangement.[ref]
Subunit counting in membrane-bound proteins by Maximilian H. Ulbrich and Ehud Y. Isacoff. Figures 1–2 and results on NR1/NR3B stoichiometry.
A count of visible steps need not equal the true number of protein subunits: some tags fail to fluoresce, and two tags may bleach too close together to resolve. The experiment therefore combines step counts with a model of labeling and detection, rather than interpreting every two-step trace as proof of a two-chain protein complex.[ref]
Subunit counting in membrane-bound proteins by Maximilian H. Ulbrich and Ehud Y. Isacoff. Discussion of fluorescent-tag probability, approximately 80%, and binomial interpretation of bleaching-step distributions.
Total internal reflection fluorescence microscopy Created 2026-10-20 Updated 2026-11-05
Total internal reflection fluorescence microscopy excites labels close to a boundary using the evanescent wave accompanying total internal reflection. Illumination travels through the higher-refractive index side, typically a coverslip, at an angle above the critical angle for total internal reflection. The field penetrates the specimen side but decays with distance from the interface.
A prism or a sufficiently high-numerical aperture microscope objective supplies the required incidence. This confines excitation near the surface and reduces background from deeper fluorescent material, making it useful for surface-associated molecular events. Changing incidence angle changes the depth weighting; an intensity change can therefore reflect vertical motion as well as molecule number.[ref]
Total Internal Reflection Fluorescence Microscopy by University of California San Francisco. Technique description: evanescent excitation close to the interface