For the linear Planck function profile, direct integration gives
in the optically thick limit. A sudden doubling of absorber abundance doubles optical depth at every physical height while initially leaving the temperature profile fixed. With , the same profile is , not . Thus
If temperature increases downward, and outgoing spectral irradiance decreases immediately because the effective emitting region moves upward into cooler gas. Subsequent thermal adjustment is outside this instantaneous comparison.
The International Linear Collider uses externally powered superconducting niobium RF cavities at about GHz, with a reference average accelerating gradient of MV/m. Superconducting walls reduce RF dissipation, allowing relatively long RF pulses and bunch trains, at the cost of cryogenic infrastructure.
The Compact Linear Collider uses normal-conducting copper structures at about GHz and a main-linac gradient near MV/m in its multi-TeV design. A separate high-current, lower-energy electron drive beam is decelerated in power-extraction structures; the resulting RF power accelerates the high-energy, low-current main beams. This two-beam concept supplies short, high-power pulses without requiring a high-power klystron at every main-beam structure.
ILC: superconducting low-loss RF; CLIC: high-gradient normal-conducting two-beam RF. Both rely on damping and final focusing to obtain very small collision spots, so energy alone does not determine their luminosity. [ref] [ref]
For a comparison appropriate to this 2012 examination, use the reference-design and conceptual-design targets rather than later revised starting stages:
The ILC reference programme included scanning approximately – GeV and a possible TeV upgrade. The CLIC 2012 studies included lower-energy construction stages as well as the ultimate multi-TeV machine. These are design goals, not achieved operating luminosities.
Collider luminosity sets the event rate for a process of cross-section through ; it is not radiated optical power. [ref] [ref]
Both machines are proposed electron–positron linear colliders, using sources, damping rings, bunch compressors, two opposing main linacs, and final-focus and beam-delivery sections that bring very small bunches to an interaction point. The spent beams go to extraction lines and beam dumps rather than making repeated collision turns.
In the exam-era International Linear Collider reference design, polarized electrons and an undulator-based positron source feed damping rings and two superconducting main linacs; the full GeV centre-of-mass facility is about km long. The Compact Linear Collider adds high-current drive-beam generation and deceleration lines parallel to its main linacs; its TeV concept is roughly km long. The linear layout avoids the repeated synchrotron-radiation losses that would be severe for multi-hundred-GeV electrons in a storage ring. [ref] [ref]
Use a calibrated, nonintercepting DC beam current transformer to measure the circulating current repeatedly during a fill, with top-up injection absent or separately recorded. At fixed revolution frequency, , so a fit to versus time gives slope for exponential decay. The transformer's zero offset and long-term drift must be controlled, especially at low current. An AC current transformer or a calibrated bunch pickup can additionally resolve bunch charge, whereas a DC transformer provides the total circulating intensity needed here.
Particles are lost when a process drives their transverse amplitude or energy outside the machine's accepted region. Principal causes include scattering from residual gas; Touschek scattering within a bunch, which can convert transverse momentum into excessive longitudinal momentum; collision losses at an interaction point; diffusion from nonlinear resonances, field or RF noise; and collective instabilities or insufficient RF acceptance. Mechanical aperture restrictions turn large-amplitude motion into a loss.
Synchrotron-radiation energy loss is normally replenished by RF, so it does not by itself remove one electron for each emitted photon. Rare large energy deviations can nevertheless contribute to losses if they exceed the accepted energy range. Continuous top-up injection can hide the underlying decay and must be accounted for when measuring a lifetime.
The instantaneous beam lifetime is
where losses make . If the fractional loss rate is constant, and is the time to fall to of the starting population. At fixed revolution frequency, the circulating current has the same exponential decay. Density-dependent loss mechanisms can make the instantaneous lifetime vary, so a single exponential need not fit every fill.
The RF harmonic number is the number of RF cycles per revolution, so . For ,
The synchronous phase fixes which phase of that voltage is sampled, not the frequency ratio. For a sine voltage, gives zero net accelerating voltage and describes a stationary ideal-energy condition; an actual energy ramp requires a phase producing the required energy gain. A different phase-origin convention changes that statement about the zero of phase, but not the boxed frequencies.
The quoted proton energies are explicitly kinetic. For mean ring radius m,
Using these expressions rather than setting at injection gives
The frequency approaches as energy increases; it is the velocity increase, not a change in the prescribed mean ring circumference, that produces the frequency sweep.
As the star expands onto the red giant branch, a planet of fixed radius produces a shallower exoplanet transit, . For a fixed circular orbit and an approximately central chord, duration grows approximately as , and transit probability also rises. At fixed orbital inclination the impact parameter in stellar-radius units decreases, further changing the chord. These statements neglect orbital evolution, stellar mass loss, tidal effects and eventual engulfment, all of which can matter for a very close planet.
Limb darkening makes the central stellar surface brighter than the disk mean. A small planet at projected position blocks fractional flux approximately . A central transit is therefore deepest near mid-transit and rounded rather than flat-bottomed; a near-limb chord can be shallower. The geometrical contact times do not change for fixed radii and orbit, although a threshold-based measured duration can change because ingress and egress are fainter.
Reducing orbital inclination from exactly edge-on increases the impact parameter and shortens the chord, giving in the small-planet, circular approximation. For a uniformly bright disk, a fully internal transit retains approximately the same exoplanet transit depth . Once grazing, the occulted area and exoplanet transit depth decrease; for the exoplanet transit disappears. With limb darkening, a higher- path is also typically shallower before grazing.
A strongly moving lung target is a relative contraindication to a particular proton therapy plan if respiratory motion and changing air–tissue paths make robust target coverage and normal-tissue constraints unattainable. A changing water-equivalent path changes the particle range; pencil-beam scanning can also interact with respiratory motion. A photon radiotherapy plan may then offer more reliable coverage despite its greater exit dose. This is a conditional planning contraindication, not a blanket claim that lung cancer cannot be treated with protons: gating, breath-hold, rescanning and adaptive planning can change the decision. If a robust comparative plan shows no meaningful benefit, the additional cost and access burden also weigh against the proton plan.[ref]
A localized paediatric intracranial tumour is a representative indication where proton therapy can reduce unnecessary absorbed dose to the developing brain and other normal tissue. The finite particle range can reduce exit and integral dose compared with many photon radiotherapy plans, which may reduce late effects and secondary cancer risk over a long expected survival. It remains necessary to maintain target coverage, account for changing anatomy and keep uncertain distal-edge relative biological effectiveness away from sensitive structures. Travel, cost and daily positioning are practical disadvantages. The relevant comparison is a robust individual treatment plan and clinical endpoint, rather than the label “proton” alone.[ref]
Alice's outcome is random. Conditional on knowing it, Bob may assign a different quantum state, but without that classical record he sees the same density matrix. For the displayed pure two-qubit state, his reduced density matrix before Alice's measurement is
After Alice's computational-basis measurement with the outcome unannounced, the weighted mixture is exactly this same matrix. More generally, for any local trace-preserving operation with measurement operators ,
The equality follows from the cyclic property of the partial trace for operators acting on Alice's subsystem. Bob's every local outcome probability therefore remains unchanged. This is the no-communication theorem: . Conditional state changes become usable correlations only when the classical outcomes are compared.
Expand a normalized product state as
Thus , , , , giving
Conversely the nonzero coefficient matrix has determinant zero precisely when it has rank one, so the condition also suffices for a pure two-qubit state to factor.
For any fixed pair of local measurement settings with operators , the Born rule factorizes:
Hence a product state has independent local results in every pair of local bases. This assumes independent settings and local measurements; shared classical randomization of preparations or a subsequent joint interaction can generate correlations. A separable mixture is not necessarily a single product state.
When , the observed relative frequencies converge, for large sample size, to the conditional probabilities
Equality says that the second binary outcome has the same distribution whichever first outcome occurred; this is independence of these two particular measurement results. Cross-multiplication gives
For finite samples the two empirical fractions fluctuate; they are estimates, not exact deterministic equalities. If or , the missing conditional fraction is undefined, but one outcome is constant, so the joint measurement results are independent and the displayed modulus identity still holds.
This criterion only addresses the computational-basis statistics. For example
has all four joint probabilities equal to , yet is maximally entangled: its first-qubit density matrix is and . Moreover classical correlations of mixed separable states also exist, for example . Correlations in a single basis alone neither certify nor exclude quantum entanglement.
Measuring the first qubit applies or . The Born rule gives
The normalized conditional quantum states are
Each expression applies only when its denominator is nonzero; an impossible outcome has no defined conditional state.
A pure bipartite quantum state is entangled if it cannot be written as a tensor product . More generally a mixed quantum state is entangled if its density matrix cannot be expressed as a convex mixture of product density matrices. Two applications are quantum teleportation, which transfers an unknown qubit using a shared entangled pair plus classical communication, and superdense coding, which uses a shared entangled pair and transmission of one qubit to communicate two classical bits. Neither permits faster-than-light communication.
Let and retain the positive spin beam at every stage. The overlap of successive positive eigenstates is
Thus the unconditional survival probability, relative to the original intensity, is
The last retained quantum state is , so its final negative- result is certain conditional on survival and adds no further factor. In particular , , and . Since ,
This is a changing-measurement-axis form of the quantum Zeno effect: frequent selections steer the surviving spin through a continuous succession of nearby eigenstates.

There are unlisted articles, also show them or only show them.