Past exam of the biological physics course of the University of Oxford 2019 2 a ii Solution 2026-10-25
The intracellular recording by Alan Hodgkin and Andrew Huxley shows the membrane voltage rising from a negative resting value to a positive overshoot, with the outside held at zero reference. The action potential therefore does more than transiently abolish a resting polarization: it reverses the sign across the membrane. A simple hypothesis that excitation only makes an otherwise potassium-dominated membrane equally leaky cannot explain that positive overshoot.
The result helped motivate a transient, selective change in membrane permeability, later resolved into rapid inward sodium current followed by outward potassium current. The positive sodium equilibrium potential calculated above makes the overshoot physically plausible, while potassium conductance favours a negative resting voltage and repolarization. The 1939 voltage trace itself did not identify individual channel proteins or establish the full later voltage-dependent gating mechanism; those conclusions required ionic substitution and voltage-clamp evidence.[ref]
Action Potentials Recorded from Inside a Nerve Fibre by Alan Hodgkin and Andrew Huxley. 1939 intracellular recording and reversal of membrane voltage during excitation
Past exam of the biological physics course of the University of Oxford 2019 2 a i Solution 2026-10-25
Take . Equality of electrochemical potentials for a monovalent cation gives the Nernst equilibrium potentialAt , . ThereforeThe signs refer to the stated electrode convention, not to the direction of current at every voltage. Activities are approximated by concentrations and the bulk ionic concentrations are treated as fixed during a single spike.
Past exam of the biological physics course of the University of Oxford 2019 1 c ii Solution 2026-10-25
Write and . Then , soThereforeAt the optimum, the two contributions are equal. Expressing the optimal sliding length directly in terms of the minimum time givesThese relations concern the optimal point; a general nonminimal time can correspond to two different sliding lengths. A geometric or kinetic restriction on the allowed sliding length can instead place the optimum at a boundary.
Past exam of the biological physics course of the University of Oxford 2019 1 c i Solution 2026-10-25
The term is the bulk-diffusion search cost: increasing the effective length of DNA searched after each encounter enlarges the useful capture region and reduces this contribution. The term is the accumulated sliding cost. Approximately DNA landing-and-sliding episodes, each taking order , give . These are scaling estimates; geometric constants and correlated revisits are omitted by the supplied model.
Thus the facilitated target search is slow as , because too little sequence is examined per encounter, and slow at very large , because sliding and repeated local exploration take too long. A finite intermediate minimum balances 1D scanning against 3D relocation. The right panel of the figure in solution shows the two contributions and their sum. The model requires a useful range of sliding lengths below the full chromosome length, finite positive diffusion coefficients and effective relocation between episodes; it is not a claim that arbitrarily large is physically available.
Past exam of the biological physics course of the University of Oxford 2019 1 b iii Solution 2026-10-25
If the outcome is the first successful binding to any operator, ten well-separated functionally independent unoccupied targets give ten times the total capture rate. Henceor roughly – for the estimates above. This assumes nonoverlapping capture zones and no significant depletion before the first event. The first-arrival time at one designated operator is not divided by ten merely because other sites are added, and filling all ten sites is a different occupancy problem.
Past exam of the biological physics course of the University of Oxford 2019 1 b ii Solution 2026-10-25
The given sphere has radius . The Stokes–Einstein relation at an illustrative givesFor well-mixed independent searchers in cell volume , the target-arrival rate is . The corresponding mean first arrival time isThe source does not fix , the reaction radius or temperature. For an order-of-magnitude estimate, a bacterial volume around and reaction radius – give about –. A 20-base-pair B-form site is about long, supporting a nanometre-scale capture radius but not uniquely defining its spherical value. The estimate is the ideal diffusion-limited time, not a measured intracellular search time: nonspecific binding, orientational matching, crowding and limited accessibility are excluded.
Past exam of the biological physics course of the University of Oxford 2019 1 b i Solution 2026-10-25
Treat the target as a stationary perfectly absorbing sphere of reaction radius , surrounded by an effectively uniform reservoir of protein number density . At steady state the radial diffusion equation givesThe inward capture rate per target is the integral of the Fick's first law:For dilute independent targets of number density , the volume association rate is , soThis is the Smoluchowski association rate, in volume per time because the concentrations are number densities. If the target also diffuses, use the relative diffusion coefficient . Orientation constraints, incomplete absorption and chromosome geometry can reduce the actual association rate relative to this ideal collision limit.
Past exam of the atomic and laser physics course of the University of Oxford 2021 4 e ii Solution 2026-10-25
The finite nuclear size correction perturbation is unchanged for the same lead atomic nucleus. Its leading effect on one occupied orbital is still proportional to that orbital's contact density,Other electrons screen the nuclear attraction and alter the self-consistent wavefunction, usually reducing its contact density and hence its positive shift relative to the bare hydrogen-like ion. The reduction is modest for a deep orbital: it penetrates well inside most other shells and still samples nearly the full attraction. Replacing by the neutral atom's asymptotic charge one would be inappropriate for this core orbital.
A neutral lead atom has two electrons. Their contributions add in a frozen-orbital estimate of total atomic energy, roughly twice the per-electron shift, with relaxation and correlation corrections. An experimentally observed transition frequency again depends on the difference between the finite-size shifts of both participating many-electron quantum states. A quantitative neutral-lead result requires a screened relativistic many-electron calculation, not the one-electron formula with a single universally valid effective charge.
Past exam of the atomic and laser physics course of the University of Oxford 2021 4 e i Solution 2026-10-25
A nonrelativistic wavefunction vanishes linearly at the origin. Its probability density is therefore proportional to , so its first-order finite nuclear size correction shift scales as , rather than the result for . It is positive but much smaller.
More explicitly, the normalized hydrogen-like ion radial function obeys near the origin. Since the spherical harmonic has unit angular norm,ThusThis is about in the nonrelativistic model. At large , the relativistic Dirac spinor has an -type small component and a much stronger nuclear sensitivity than this nonrelativistic argument predicts; remains much more suppressed. Neglecting spin-orbit interaction corrections would miss that distinction.
The general thin gravitational lens equation is a two-component angular relation,For a spherical lens, image, source and lens centre lie in one plane containing the line of sight. Choose its sky direction as a signed axis. Then can be signed scalars andThey are not fundamentally scalar quantities for a general lens; the reduction uses this symmetry and axis choice. An exactly aligned source requires the full ring geometry, not a unique preferred sky axis.
Let be the reduced, observed angular displacement between source and image. In the small-angle lens geometry, the physical bending angle is weighted by the lens-to-source and observer-to-source angular diameter distances:In a Euclidean diagram this follows because the transverse displacement at the source plane is , whose observed angle is that displacement divided by . In cosmology the same thin-lens expression uses the corresponding angular diameter distances. For a signed one-dimensional coordinate, the direction is supplied by the image's side of the lens.
The evolving optical and infrared kilonova was consistent with radioactive heating of neutron-rich merger ejecta. Rapid neutron capture, the r-process, can synthesize nuclei heavier than iron; decay of the newly formed unstable nuclei powers the transient. Its redward evolution and large inferred opacity supported production of heavy-element-rich ejecta. Thus mergers are a demonstrated important site for heavy-element production, while the fractions of individual elements and their total cosmic contribution remain model-dependent. The transient was not a direct identification of every very heavy element.[ref]
Multi-messenger Observations of a Binary Neutron Star Merger by LIGO Scientific Collaboration and others. Kilonova interpretation and conclusions: optical/infrared evolution and radioactive r-process heating
The short gamma-ray burst GRB 170817A followed the merger signal by about , providing direct evidence that at least some short gamma-ray bursts arise from neutron star mergers. The association connects their high-energy emission and relativistic outflows to compact-binary coalescence. It does not establish that every short burst has this progenitor, nor that the observed gamma-ray luminosity is independent of viewing angle.[ref]
Multi-messenger Observations of a Binary Neutron Star Merger by LIGO Scientific Collaboration and others. Abstract and multiwavelength counterpart discussion: GRB 170817A delay and association
GW170817 supplied the first direct gravitational wave observation of a binary neutron star inspiral. The chirping waveform tests compact-binary general relativity, constrains masses and tidal effects, and links a class of known compact binaries to observable sources of gravitational waves. The electromagnetic counterpart identifies the host and distance, enabling complementary source and cosmological inference. This is distinct from the earlier binary-black-hole detections; it established a system involving matter that could also be observed electromagnetically.[ref]
GW170817: Observation of Gravitational Waves from a Binary Neutron Star Inspiral by LIGO Scientific Collaboration and Virgo Collaboration. Abstract and source-inference discussion: first binary-neutron-star inspiral, mass range and electromagnetic association
For a small radial comoving interval, . At ,ThusThis uses the unbound cosmological radial separation between separate quasars, unlike the peculiar-velocity redshift dispersion of galaxies inside the bound group. Integrating the distance relation instead of linearizing gives a small correction for a specified direction and endpoint. The quoted characteristic spacing alone does not assert that the same nearest object lies both purely transverse and purely radial.
For a transverse comoving separation Mpc in a flat universe, the corresponding distance is the transverse comoving distance , soEquivalently the physical separation is Mpc and dividing it by Mpc gives the same angle. Dividing 100 comoving Mpc directly by would mix scale conventions. The density's Mpc is a characteristic inter-object spacing; a particular nearest neighbour has a distribution of distances and orientations.
Nearly radial orbits have small transverse motion: . A bounded steady population contains both inward and outward phases, so large radial dispersion is compatible with zero mean radial velocity. Positivity of the distribution function and stability can impose further restrictions on particular radial models.
For an ensemble of nearly circular stellar orbits with randomly oriented planes, radial motion is small while tangential motion is substantial: . The two tangential variances remain equal by spherical symmetry. There need not be bulk rotation even though individual stars move on nearly circular paths. The anisotropy parameter is strongly negative; its exactly circular limit is singular as .
For two black holes of equal mass, and . The prescribed instantaneous orbital decay timescale givesThe integrated ten-billion-year criterion gives h. These large initial periods compared with a neutron-star pair reflect the stronger radiation reaction of the more massive system.
There are unlisted articles, also show them or only show them.