Agarose 2026-10-18
A polysaccharide that forms a porous gel on cooling from solution. In agarose gel electrophoresis, the agarose network provides a size-dependent obstacle to DNA migration in an electric field.
Agarose gel electrophoresis Created 2026-10-14 Updated 2026-10-18
Agarose gel electrophoresis uses a porous agarose polymer network. For linear double-stranded DNA within a suitable separation range, shorter fragments generally move farther in a fixed run. Raising the agarose concentration changes the mesh and the range of sizes that can be resolved.[ref] A compact circular DNA molecule need not migrate like linear DNA of the same length: geometry affects passage through the mesh.[ref]
A concrete laboratory example is Addgene's documented DNA separation protocol. Its standard 1% gel contains 1 g of agarose in 100 mL of TAE buffer. Dissolved agarose sets in a casting tray around a comb; removing the comb leaves sample wells. The gel is covered with the same buffer solution in a box connected to a voltage source. Loading buffer contains glycerol to increase sample density and a tracking dye to show run progress. A DNA ladder occupies a separate lane beside the samples. With wells near the negative cathode, DNA migrates toward the positive anode. After separation, bound stain makes the DNA visible by fluorescence under a UV transilluminator. The DNA ladder supplies the size reference; the tracking dye monitors migration but does not identify sample DNA.[ref]
In the manufacturer's controlled comparison, the same DNA ladder runs in 1%, 2%, and 3% agarose gels with the same run time and other stated conditions. The changed gel band spacing shows why a calibration belongs to its particular gel conditions, rather than establishing a universal distance law.[ref]
In interpreting an unknown sample, a blank lane tests for detectable background or carryover in that blank, while the DNA ladder checks migration and detection of its known fragments. An empty sample lane cannot by itself distinguish absent DNA from unsuccessful loading or insufficient detection. These controls answer different questions; neither makes matching migration a proof of matching nucleotide sequence.
Gel electrophoresis Created 2026-10-13 Updated 2026-10-18
Separation of charged molecules through a gel in an electric field. Denaturing conditions suppress folded structures, helping compare RNA lengths; matching migration alone does not establish an identical nucleotide sequence or identical covalent bonds. In the ribozyme experiments, labelled RNA was detected after separation by exposing photographic film.
In DNA agarose gel electrophoresis, the backbone phosphate groups carry negative electric charge under the usual mildly alkaline buffer solution conditions. DNA therefore moves toward the positive anode, away from the negative cathode.[ref]
The electric field points the other way: the electric force reverses direction when . The apparatus is driven by an external source of electric potential difference; the positive anode convention here belongs to that operating mode. Direction follows electric charge, so it is not a rule that all molecules move toward the same electrode.
The useful result is a spatial comparison: a mixture becomes separated gel bands, which can be compared with a DNA ladder or recovered for subsequent analysis. Agarose gel electrophoresis of linear double-stranded DNA, gel electrophoresis of denatured RNA, and SDS-PAGE of proteins use different conditions to make migration informative about chain size. An electric field supplies motion; the gel supplies a porous obstacle course.
Figure 1.
DNA migrates toward the positive anode, opposite to the electric field; the agarose mesh separates linear DNA fragments. Conceptual apparatus and mesh, not measured trajectories or a drawing to scale
. Details.
In the weak-field reptation regime of agarose gel electrophoresis, the electrophoretic mobility of a long linear DNA chain scales as , where is its number of base pairs. One way to see the scaling is that the constrained-chain diffusion coefficient scales as , whereas its effective electric charge scales as ; the drift response is proportional to . With the same electric field and running time, the migration distance is therefore . The time cancels from the ratio, giving
Here “kbp” means a thousand base pairs, not a rate. The second gel band has traveled farther and corresponds to the shorter chain under this migration model. The inverse-length law applies only over an appropriate migration regime.[ref].
At very low agarose concentration the mesh becomes too open to sieve these chains effectively. In the free-solution limit the chain's electric charge and friction are both approximately proportional to its length, so both chains have nearly the same electrophoretic mobility and their gel bands cease to separate well. At very high agarose concentration the pores become small and transport is strongly hindered; over a fixed experimental time both chains migrate very little, so their absolute spatial separation again becomes small. Increasing gel concentration can improve resolution over an intermediate range, but not indefinitely.
The numerical result is conditional on the inverse-length reptation law. Actual gel electrophoresis size calibration often uses an empirical approximately linear relation between distance and over a specified range. One known band alone cannot fix that relation's slope. The PDF supplies neither gel concentration nor a calibration curve, so is the standard model estimate rather than a uniquely calibrated experimental size.