The vesicle lumen is the enclosed interior of a vesicle, separated from the cytosol by its lipid bilayer. It can contain dissolved cargo, ions and portions of membrane proteins facing inward. In a synaptic vesicle, for example, the neurotransmitter is stored in the vesicle lumen before exocytosis.
Membrane topology makes this interior useful to track. When a vesicle buds from the endoplasmic reticulum, its vesicle lumen derives from the interior of the endoplasmic reticulum; fusion with the Golgi apparatus delivers the cargo into the next lumen without exposing it to the cytosol. When a secretory vesicle undergoes exocytosis, the vesicle lumen opens to the extracellular space. Thus an enclosed compartment can transport material through a biological cell while keeping it on the same side of a cell membrane throughout.[ref]
Molecular Biology of the Cell, 4th edition by Bruce Alberts and others. Chapter 13, The Molecular Mechanisms of Membrane Transport and the Maintenance of Compartmental Diversity: conservation of membrane orientation during budding and fusion
Whole-cell recording Created 2026-10-13 Updated 2026-11-05
Whole-cell recording establishes intracellular electrical access by rupturing the membrane under a sealed patch pipette while retaining the gigaohm seal. Under adequate voltage clamp, the measured electric current combines contributions from accessible ion channels, membrane capacitance and seal leak current. Current clamp instead follows membrane potential while supplying a chosen electric current. Whole-cell recording is useful for linking a biological cell's total electrical response to its ion channels, but neither mode automatically controls distant dendrites or preserves the original cytosol.
In the 1981 methods demonstration, a bovine chromaffin biological cell was tested before and after patch rupture. Small voltage clamp steps produced a much larger capacitive transient after break-in. Integrating it gave for a cell; its decay indicated patch-clamp series resistance below . Depolarizing commands then revealed ionic electric currents. Separate current clamp recordings showed spontaneous action potentials. The comparison established access to the cell interior, rather than a claim that every pipette command equals membrane potential. Slower transients sometimes indicated incomplete rupture, and these small-cell results do not establish spatial control of a branched neuron.[ref]
Improved patch-clamp techniques for high-resolution current recording from cells and cell-free membrane patches by O. P. Hamill and others. pp. 98–99, Figure 15 and following voltage-clamp and current-clamp discussion
Synthetic whole-cell recording: patch-clamp series resistance and passive responses
. An original equivalent electrical circuit uses , and . The current clamp step and voltage clamp step are separate synthetic experiments. The passive model omits active ion channels, seal leak current, pipette capacitance and amplifier dynamics. Curves are calculations, not experimental measurements. Details.