Weissenberg–Rabinowitsch equation Created 2026-09-29 Updated 2026-11-05
The Weissenberg-Rabinowitsch equation recovers the wall shear rate of a generalized Newtonian fluid from a measured pressure-drop versus flow-rate curve. For steady fully developed flow in a horizontal circular pipe with radius , length and no slip, define positive wall shear stress
If is the volumetric flow rate, the wall shear rate is
The derivative samples the local slope of the measured flow curve.
To derive it, momentum balance gives . With and , integrating the velocity profile gives
Differentiating proves the formula. This assumes a local stress/shear-rate relation at the specified measurement conditions; elastic memory or wall slip requires additional modeling.
For a power-law fluid with , , one has and
The Newtonian case recovers . The correction is useful because a non-Newtonian wall shear rate cannot generally be inferred from the Newtonian expression alone.
A point mass attached to a light inextensible string winds around a fixed smooth circular pole of radius . Let the initial straight free length be , and assume the string remains taut without slipping over the part already laid on the pole. Since its tension is perpendicular to the point mass's velocity, the speed stays constant. If the contact point turns through , the free length obeys , while the involute geometry gives . Thus , or . First contact of the point mass with the pole occurs at , after . In the ideal model, the required tension diverges at contact; finite string strength or finite particle size limits that idealization.
Worm-like chain force-extension interpolation Created 2026-10-25 Updated 2026-11-05
The interpolation links chain extension to entropic tensile force, with contour length and persistence length . Small extension gives spring constant ; near the force stiffens as . The divergence assumes an inextensible backbone and is not a physical infinite tensile force. A branch fit estimates available contour and flexibility, not an unfolding activation barrier by itself.
X unit 2026-10-18
The historical X unit was a practical X-ray wavelength unit, approximately . Its scale used an assigned calcite spacing; relative wavelength measurements could be more precise than absolute determinations. Variation between crystal specimens led to calibration using reference spectral lines. An X unit value therefore cannot simply be read as an exact multiple of .[ref]
An angular-scale check determines how an indicated rotation corresponds to an angle. A reference line transfers a wavelength scale. An absolute determination ties that scale to an independently established length standard. These are different calibration tasks. Repeating measurements can reduce random scatter without correcting the common scale: if every inferred is too large by a chosen , all inferred absolute wavelengths are too large by , while ratios using that same are unchanged.
Zero-rest-length spring Created 2026-10-20 Updated 2026-11-05
A zero-rest-length spring has quadratic potential energy in its actual length , with no subtracted natural length. It is a useful idealization, not an ordinary unstretched spring of arbitrary length. For an end-to-end spring on a two-link pendulum, changing the natural length changes the quadratic bending stiffness about the straight configuration.