For the stated magnetic vector potential, part a gives
Applying the same identity once more and using the Ampère-Maxwell equation in the magnetostatic limit gives
Expanding the Lorentz force density , using and the vector triple-product identity, separates its poloidal and azimuthal parts:
where
In an axisymmetric magnetostatic state, pressure and gravitational forces are poloidal, so the azimuthal component of the Lorentz force density must vanish. Hence and
The two gradients are locally parallel, so is constant on each regular level surface of . Therefore
for an arbitrary flux function .
A magnetostatic force-free magnetic field is in equilibrium when its electric current exerts no Lorentz force density:
Thus is pointwise parallel to , so for some scalar ,
Using the magnetostatic Ampère's law, , gives
Taking the divergence and using yields
The force-free parameter is therefore constant along each magnetic field line.
In a magnetostatic equilibrium, inertia is absent and all forces balance. A force-free magnetic field is the limiting case in which the Lorentz force density vanishes:
Thus the current density is parallel to the magnetic field, so for some scalar force-free parameter ,
Using Ampère's law in magnetostatics gives
Taking the divergence and using both the divergence of a curl is zero and yields
so
The force-free parameter is therefore constant along every magnetic field line.
Take , and . Then
Expanding the cyclic derivative of produces six second derivatives, which cancel in pairs because partial derivatives commute. Hence
This Bianchi identity contains and . The inhomogeneous Maxwell equations are
The temporal component is , since ; the spatial components give . The source suppresses the coupling factor, as in units with or a rescaled current.
For the physical Lorentz force density on matter, the consistent tensor formula is
Its temporal component is power transferred to matter per unit volume divided by . The printed expression has the opposite sign for the stated definition of in this convention. A stationary positive charge in a positive electric field is a concrete check: the physical upper spatial force is , whereas the printed expression, raised to an upper index, gives . It can represent the opposite momentum transfer to the electromagnetic field, but must not be identified with the force on the charge without changing a convention.
The electromagnetic four-potential is , and the vacuum four-wavevector is with . Define and . The given transverse potential is . Its physical fields are
so the Poynting vector points along positive . For our signature, , , and . Therefore
The square-root prefactor is simply the source's chosen wave normalization; an overall dimensional amplitude could multiply every field.
The four-current is , with . Charge conservation takes the equivalent forms
Lowering both indices of changes the sign of its time-space entries: , while . The temporal component of is , by Gauss's law. Its spatial components are , by the Ampère-Maxwell equation. Hence
For the displayed free wave the current vanishes because ; the component derivation also proves the sourced identity. The two homogeneous Maxwell equations follow separately from expressing in terms of a potential.
Force-sign qualification. With these definitions the physical Lorentz force density is , whereas the source prints the reversed contraction . Consequently
The physical time component is the power transferred to matter per volume divided by , as in Poynting's theorem. For example parallel positive and do positive work, but the literal printed contraction has negative time component. This sign cannot be repaired while simultaneously retaining the source's tensor definition and the Maxwell identity above; reverse the force contraction to describe the physical force.
Use a neutral, infinitely long wire on the axis. Denote the total current by , and write . Outside the wire the magnetic field and electric field are
These follow from cylindrical symmetry and Ampère's law. The zero temporal component of the given total four-current specifies lab neutrality; the in must refer to a carrier density, not that zero net charge density.
TODO: normalization from a literal volume current density requires the unspecified wire cross-section. The source does not supply its area or profile. The exterior field family below is fully determined in terms of ; it cannot be reduced to alone without that missing datum. If was intended as a cross-section-integrated line current instead, set and interpret its accompanying charge density as charge per length. No inside-wire profile is invented.
For a boost along positive , let . Apply the Lorentz transformation of electromagnetic fields at corresponding events:
Here the subscript labels the perpendicular-to-wire boost, not the direction of the transformed vector. In these formulas evaluate the original field at , and . The wire moves in this frame, so the fields are time-dependent. The local current transforms to , , . A nonzero transformed electric field is possible even with zero net charge density: it is not a purely electrostatic field.
For a boost along positive , the transverse coordinates are unchanged. The transformed fields are
The transformed line charge and current are and . These reproduce the radial electric field through Gauss's law. A boost comoving with the electrons removes their individual current contribution, but the positive background then moves and the total current is not zero.
For two identical wires, their lab interaction is attractive, with magnitude per length. The total four-current is spacelike, , so no inertial frame makes it a pure charge density. Also forbids a frame in which the exterior field is purely electric. For an arbitrary boost along the wires, the electrical part is repulsive and the magnetic part attractive:
The latter always dominates, and their sum remains .
Even a more general boost cannot make the entire-wire force electrical alone. At the second wire choose , so and with . The physical Lorentz force density is . If the boosted magnetic force vanished, , then would also give . Thus , which from the boost of requires . But for such a boost , whereas . The electrical term alone cannot equal the actual force. Therefore there is no such frame for both complete wires, although the force on electrons considered separately can be electrical in their rest frame.
Planetary dynamo 2026-10-14
A planetary dynamo maintains an intrinsic magnetic field by motion of an electrically conducting fluid. The resistive induction equation balances stretching and transport against magnetic diffusion. A sufficiently large magnetic Reynolds number is necessary but does not ensure that the flow regenerates every required field component. Thermal or compositional convection supplies mechanical power; rotation organizes the flow through the Coriolis force, and the Lorentz force density eventually modifies the flow and limits growth. A fluid core can fail to operate a dynamo if it is stably stratified or inadequately driven.
Resistive magnetohydrodynamics Created 2026-10-06 Updated 2026-11-05
Resistive magnetohydrodynamics retains finite magnetic diffusivity in the coupled evolution of a conducting fluid and its magnetic field. The resistive induction equation allows field diffusion relative to the fluid, while the magnetohydrodynamic momentum equation includes the Lorentz force density. It contrasts with the zero-diffusivity limit of ideal magnetohydrodynamics.
Rotating-frame magnetohydrodynamic momentum equation Created 2026-10-25 Updated 2026-11-05
For a rigid frame with constant angular velocity , add the Coriolis force and centrifugal force to the inviscid magnetohydrodynamic momentum equation. A constant magnetic permeability and solenoidal magnetic-field constraint split the Lorentz force density into magnetic pressure and magnetic tension. This nonrelativistic conducting-fluid approximation neglects the displacement current, net electric-charge force and viscosity. Differential rotation belongs to the fluid's velocity field, not to a spatially varying rigid-frame rotation vector. A time-dependent frame requires the additional Euler force.
Taylor constraint 2026-10-14
In inviscid magnetostrophic balance within an impenetrable axisymmetric container, with no azimuthal buoyancy or external mechanical torque, the cylindrically integrated Lorentz force density must vanish on every cylinder coaxial with rotation. The azimuthal pressure derivative integrates to zero, and the cylindrical Coriolis integral is proportional to net radial flux, zero by incompressibility and impermeability. Multiplying by cylinder area and lever arm gives the equivalent zero-torque form. This rotating-fluid condition is distinct from magnetic-helicity relaxation to a force-free plasma state. Its original primary source is Taylor's 1963 rotating-fluid paper.
Viscous magnetic-relaxation energy identity Created 2026-10-14 Updated 2026-11-05
For constant mass density , kinematic viscosity , ideal induction, zero boundary velocity and tangent magnetic field, put . Multiplying the momentum equation by and integrating cancels pressure work and advective flux. The magnetic-energy derivative is minus the integral of Lorentz force density dotted with velocity, canceling the same work in the kinetic-energy equation. Integration by parts then gives the displayed identity. For incompressible flow with zero boundary velocity, .