Fetal circulation Created 2026-10-31 Updated 2026-11-05
The fetal vascular arrangement, with placental gas exchange and shunts including the ductus venosus, foramen ovale and ductus arteriosus. It differs from established postnatal pulmonary circulation.
Left atrium 2026-11-05
The left atrium is the heart chamber receiving blood through the pulmonary veins and delivering it through the mitral valve to the left ventricle. It is the receiving chamber on the oxygenated return side of the pulmonary circulation.[ref]
Its role changes during the cardiac cycle. The chamber can accumulate incoming blood while its outlet is closed, pass blood onward during ventricular filling, and contribute to late filling through atrial contraction. The storage role is called atrial reservoir function.[ref]
A volume balance makes this more precise:
Here the sum includes the incoming pulmonary vein blood flow rates, and the outlet term is signed net flow through the mitral valve. In a constructed interval with total inflow L/min and zero outlet flow for s, the stored volume increases by
The example describes transient storage, not an indefinitely sustained steady state. Over a repeating cycle with no net accumulation, average inflow must equal average outflow.
The entering streams can also differ in oxygen content. Their mixed content is weighted by their blood flow rates, not by the number of vessels. Thus the same anatomical chamber supports two distinct balance questions: how its volume changes with time, and how transported oxygen combines. Its volume alone determines neither the stroke volume of the left ventricle nor the oxygen content entering the left ventricle.
The chief physiological routes are abrupt failure of blood circulation, failure of pulmonary ventilation or gas exchange, or catastrophic failure of the central control of those functions. Historical clinical accounts used labels such as syncope, asphyxia and medical coma in explaining deaths; these terms describe broad physiological failures rather than identifying the underlying diseases.[ref] A brief faint or ordinary medical coma is not itself necessarily fatal.
In primary circulatory failure, effective delivery of blood to the brain stops. Modern examples include ventricular fibrillation, pulseless ventricular tachycardia, severe bradyarrhythmia and asystole. They may arise in coronary artery disease, after myocardial infarction, in cardiomyopathy, or from inherited cardiac ion channel disorders. An electrical cause may leave little distinctive gross evidence at autopsy. These modern mechanisms refine the broad historical description of cardiac syncope.[ref]
Mechanical interruption of blood circulation gives another group: massive haemorrhage, rupture of an aortic aneurysm, cardiac tamponade, and large pulmonary embolism. The immediate deficit differs in each. Haemorrhage removes circulating volume; cardiac tamponade prevents adequate filling; pulmonary embolism obstructs flow through the pulmonary circulation. All can end with critically low cardiac output even if some electrical activity persists.[ref]
Respiratory failure includes obstruction of the airway by a foreign body, laryngeal oedema or aspiration; drowning; and depression of breathing by drugs or major brainstem injury. Oxygen delivery then fails and secondary cardiac arrest follows. Carbon monoxide poisoning and cyanide poisoning illustrate related failure of oxygen transport or use: not every hypoxic death is caused by physical obstruction of an airway.[ref][ref][ref]
A major intracranial haemorrhage or rapidly developing brain herniation can destroy or compress the pathways maintaining consciousness and breathing. A severe disturbance of electrolytes, especially potassium, may instead act directly on the heart's electrical function. A fatal seizure can involve respiratory and circulatory mechanisms; sudden unexpected death in epilepsy remains a diagnosis requiring exclusion of other causes, not merely recognition of a history of epilepsy.[ref]
The practical distinction is between mode, immediate mechanism and underlying cause. For example, rupture of an aneurysm can cause haemorrhage, then circulatory failure, then irreversible hypoxic-ischaemic brain injury. A complete explanation identifies that chain. Inspection, histology, examination of the airway and heart, and appropriately interpreted toxicology may establish it; an unexplained sudden death cannot be assigned a precise cause from its suddenness alone.
Pulmonary circulation Created 2026-10-31 Updated 2026-11-05
The pulmonary circulation carries blood from the right heart through the lungs and back to the left heart. It supports exchange of oxygen and carbon dioxide. Its pressure load differs from the systemic circulation even though long-term net flow through both circuits must balance.
Pulmonary trunk 2026-11-05
The pulmonary trunk is the common artery leaving the right ventricle through the pulmonary valve before dividing into the vessels supplying the two lungs. It is the initial shared segment of the pulmonary artery route in the pulmonary circulation. The name artery describes flow away from the heart; the blood in the pulmonary trunk has not yet acquired oxygen in the lungs.[ref]
At a junction with negligible storage, conservation of mass gives
A constructed total blood flow of L/min could therefore divide into and L/min. Measuring the total does not establish equal flow to the two lungs. In a simple steady model with a common upstream and downstream pressure, branch blood flow rates depend on their respective vascular resistance values; the shared inlet does not force the resistances to be equal.
The pulmonary trunk also supplies an important distinction between two measurements. Right ventricular ejection fraction describes change in a chamber volume, whereas forward blood flow in the pulmonary trunk describes transport through a vessel. They agree through stroke volume and heart rate only under the relevant balance assumptions, including negligible backward flow. An anatomical connection is therefore the starting point for a flow model, rather than a substitute for its assumptions.
Pulmonary valve 2026-11-05
The pulmonary valve is the heart valve between the right ventricle and pulmonary trunk. During forward ventricular ejection it allows blood to enter the pulmonary circulation; closure limits return from the pulmonary trunk into the relaxing right ventricle.[ref]
Its pocket-like cusps respond to the changing pressure difference. Unlike the tricuspid valve, the pulmonary valve has no attached chordae tendineae or papillary muscles.[ref] Thus the same direction-control task is achieved by different supporting structures at the chamber inlet and outlet.
A deliberately idealized valve model sets forward blood flow to zero when the downstream pressure exceeds the upstream pressure, and permits positive flow when ventricular pressure exceeds trunk pressure. This model captures direction but omits the inertia and deformation of real cusps. It is useful for checking the sign of a flow term, not for predicting an exact opening time.
For example, if a constructed cycle sends 80 mL forward and 10 mL backward across the pulmonary valve, net transport is 70 mL. Counting only the positive part of blood flow overestimates net delivery. This is why stroke volume inferred from changing chamber volume and net forward flow in the pulmonary trunk require compatible assumptions about valve function.
Pulmonary vein 2026-11-05
A pulmonary vein returns blood from a lung to the left atrium. The pulmonary veins complete the return side of the pulmonary circulation, after blood has received oxygen in the lungs. They are veins because they carry blood toward the heart, even though their oxygen content is higher than that of the blood arriving through the pulmonary artery.[ref]
Following a parcel of blood makes the sequence clear: right ventricle, pulmonary trunk, vessels of the lungs, pulmonary vein, left atrium, then left ventricle. The pulmonary vein connects the lung circuit to the receiving chamber of the left heart; it does not drain directly into the right atrium.
A simple oxygen balance illustrates why both content and flow matter. Suppose two returning streams have blood flow rates and oxygen contents . If they mix without further oxygen exchange, the left atrium's inflow content is
For constructed values L/min, L/min, and mL/mL, this gives mL/mL. An unweighted average would give mL/mL. A specimen's vessel connections establish where the streams meet; conservation of mass establishes how their transported oxygen combines.
Right atrium 2026-11-05
The right atrium is the heart chamber receiving blood from the superior vena cava, inferior vena cava and coronary sinus. Its principal outlet is the tricuspid valve, leading to the right ventricle.[ref] This places it between systemic venous return and the pump supplying the pulmonary circulation.
The right atrium is both a junction and a chamber that can store blood. For a simple volume balance,
where sums the incoming blood flow rates and is net outward flow through the tricuspid valve. If a constructed inflow exceeds outflow by L/min for min, atrial volume increases by 50 mL. Such an imbalance cannot persist indefinitely in a fixed-volume steady-state model. Over a repeating cardiac cycle, the time-averaged inflow and outflow must balance if there is no net accumulation.
The joining streams can have different venous oxygen content. Their location in one chamber does not guarantee instantaneous perfect mixing at every sample position. Calculating mixed venous oxygen content requires a representative mixture, with the entering blood flow rates supplying the weights. This connects an anatomical chamber to the sampling assumptions behind the Fick principle.
Systemic circulation 2026-11-05
The systemic circulation carries blood from the left ventricle through body tissues and back to the right atrium. Its main arterial outflow is the aorta, and major venous return channels include the superior vena cava and inferior vena cava.[ref] The separate pulmonary circulation then passes through the lungs before blood returns to the left heart.
The two circuits operate in series, while many systemic tissue beds receive arterial supply in parallel. In an original fixed-resistance model, beds sharing pressure difference have
For a stipulated mmHg and two resistances 30 and , flows are 3 and 1.5 litres per minute, totaling 4.5. The equivalent resistance is 20 in those resistance units. Adding flows is appropriate here; adding parallel resistances is not.
Real vascular resistance changes with vessel geometry and physiology. Some routes also contain successive exchange beds, as in a portal system. The parallel-bed calculation is therefore a deliberately reduced model, not a complete vessel map.
Conservation of mass constrains sustained output from the right and left heart. If their flows differ, a vascular compartment must gain or lose blood. For the pulmonary pool,
A hypothetical imbalance of adds 0.2 litres in one minute if maintained. Long-term matching of flows is a consequence of finite storage, rather than a rule that both instantaneous waveforms must be identical.
For a whole-body oxygen balance, systemic cardiac output must be paired with compatible arterial and mixed venous oxygen content. A regional venous sample answers a regional question; it does not become whole-body return simply because it was taken from a large vein.
Tricuspid valve 2026-11-05
The tricuspid valve is the right atrioventricular heart valve, between the right atrium and right ventricle. It permits filling from the right atrium and limits backward blood flow during ventricular contraction.[ref]
The leaflets are supported by chordae tendineae attached to papillary muscles. Rising ventricular pressure brings the leaflets together; tension in the supporting apparatus helps prevent their displacement into the right atrium. The papillary muscles do not need to pull the leaflets open to initiate filling.[ref]
A useful mechanical analogy is a pressure-loaded flap restrained by tethers. The pressure difference supplies a load, while the tethers limit how far the flap can move. The analogy distinguishes the role of the chordae tendineae from the action of a motorized door.
The valve also determines how to interpret right ventricular ejection fraction. Suppose a constructed ventricular contraction reduces cavity volume by 80 mL, but 20 mL of that loss returns through the tricuspid valve into the right atrium. Only 60 mL remains for forward transport through the pulmonary valve, if other transfers are negligible. The measured cavity-volume change is still 80 mL. An ejection fraction calculated from chamber volumes therefore does not by itself measure the useful forward stroke volume of the pulmonary circulation.
Venous thrombosis Created 2026-10-31 Updated 2026-11-05
Formation of a thrombus in a vein. Obstruction impairs venous return and can cause local swelling, while detached material can reach the pulmonary circulation.