Liquid-liquid equilibrium 2026-11-05
At fixed temperature and pressure, liquid-liquid equilibrium is stable coexistence of distinct liquid thermodynamic phases that minimizes total Gibbs free energy for the specified component amounts. Their compositions can differ even though each exchanging chemical species has the same chemical potential in both phases. For neutral, nonreacting components in bulk phases at common temperature and pressure , neglecting external-field and interface-curvature contributions,
To see why, transfer an amount from phase to phase while holding the total amount of each component fixed. The change in Gibbs free energy is . If the coefficient is nonzero, one transfer direction lowers . Equality removes that driving term; stable equilibrium additionally requires a global minimum over the allowed phase arrangements. Here each chemical potential is the partial derivative of Gibbs free energy with respect to that component amount at fixed temperature, pressure and the other component amounts.[ref]
Charged species instead require equality of the corresponding electrochemical potential. Equal chemical potentials for neutral species do not require equal mole fractions. With a common pure-component reference, and , where is thermodynamic activity, an activity coefficient, and the molar gas constant. The activity equality for coexisting liquids is . Different nonideal environments can therefore support different compositions at the same chemical potential.
For a binary mixture, let be the mole fraction of component B and let be the homogeneous molar Gibbs free energy at fixed . Differentiating gives
Equality of both component chemical potentials between two compositions becomes the common-tangent construction for phase coexistence:
In this molar representation, the tangent slope is and its intercept is . Stable coexistence uses a supporting tangent lying below the homogeneous curve over all admissible compositions. This constructs the relevant convex envelope; two stationary points or equal slopes alone do not establish stability.
An original regular solution calculation makes this distinction visible. Because linear composition bias leaves coexistence compositions unchanged, subtract the linear pure-component reference and write
The dimensionless parameter penalizes unlike contacts when it is positive. Take . Symmetry makes the coexistence tangent horizontal, and the two outer solutions of give the symmetric regular-solution binodal:
These are model compositions, rather than measured hexane–water values. At overall mole fraction , the liquid-liquid tie line and lever rule give the fraction of total moles in phase :
Changing within the coexistence interval changes phase amounts while leaving the two endpoint compositions fixed. These mole-based phase fractions need not equal volume fractions.
The spinodal answers a different question: local stability of a homogeneous mixture. Here , so at the two local-stability limits are . Between them, composition fluctuations lower the bulk free energy. Between a binodal endpoint and the nearer spinodal, the homogeneous state has positive local curvature but a lower-energy phase-separated state exists: this is metastability. Thus the observed coexistence compositions are not obtained merely by setting .
Figure 1.
Original regular-solution model: the supporting tangent gives liquid coexistence, while the spinodal marks loss of local homogeneous stability.
Details.
A useful experiment measures compositions as well as the presence of layers. One hexane–water record reports overnight shaking, microsyringe sampling of the aqueous solution, and gas chromatography to measure dissolved hydrocarbon. The small dissolved amount is evidence of finite mutual solubility, consistent with liquid immiscibility over other bulk compositions.[ref] At controlled temperature, repeated sampling of both phases and checks from different initial compositions help test whether the endpoint compositions have stabilized. Critically evaluated reference systems provide a way to validate such instruments and techniques.[ref]
Liquid-liquid tie line 2026-11-05
A liquid-liquid tie line joins the compositions of two liquid phases that coexist at a specified temperature and pressure. Its endpoints describe the separate phases; an interior point describes an overall composition formed from suitable amounts of them. The liquid-liquid tie line therefore connects equilibrium chemistry with material balance rather than describing a spatial boundary between layers.
For a binary mixture, use component-B mole fractions , and overall fraction . If is the mole-based phase fraction in phase , conservation of component B gives the lever rule:
The endpoints must be different and . For invented coexistence endpoints , and overall , the result is . In a -mole sample, the phases contain and moles; their component-B amounts are and moles, totaling . These mole amounts do not specify the two layer volumes.
A ternary liquid-liquid tie line obeys the same vector balance. For chosen endpoint vectors and , a phase fraction gives . Every component must give the same . A normalized composition vector need not lie on this particular line; normalization alone does not establish compatibility with the proposed endpoints.
The lever rule determines amounts after equilibrium endpoints have been established; it does not select those endpoints. They can come from measured phase compositions or a stable common-tangent construction for phase coexistence. Reliable experiments control temperature and sample purity, measure the separated compositions and distinguish genuine liquid-liquid equilibrium from other phase behavior. An IUPAC reference-system assessment specifically warns that turbidity can confuse liquid–liquid and solid–liquid transitions.[ref]
The residual correction in tie-line sensitivity accounts for rotation of a fitted liquid-liquid tie line when the measured overall composition does not lie exactly on it. In independent mole fraction coordinates, set , hold a symmetric positive-definite matrix fixed, and use the interior unconstrained tie-line phase-fraction fit. With , residual , and row vectors , , its differential is
The full derivation is in tie-line phase-fraction sensitivity. The normal equation makes orthogonal to in the chosen metric; it does not make the residual zero.
For an original example, take , , and . The third mole fraction is fixed by closure. These choices give
Increasing only the first coordinate of by predicts a phase fraction change . Omitting the correction misses the second contribution even though the fit satisfies its normal equation. A centered finite-difference recalculation as the perturbation shrinks tests this derivative directly.
This is a local sensitivity, not an uncertainty until combined with the joint input covariance matrix.[ref] The formula assumes distinct endpoints and an interior fit with fixed . A changing metric requires sensitivity of a tie-line fit to its weight matrix; a constrained boundary requires a separate local analysis. A nonzero residual can reflect composition noise or model mismatch and does not independently establish liquid-liquid equilibrium.
A ternary liquid-liquid tie line joins the compositions of two coexisting liquid phases in a three-component mixture at a specified temperature and pressure. IUPAC defines a tie line by its coexisting equilibrium endpoints.[ref] Each composition is a vector of mole fractions satisfying . Only two coordinates are independent; a triangular composition diagram displays this constraint.
If is the mole-based phase fraction in phase , conserving every component gives
This is the lever rule in vector form. Wherever , each component must give the same value
A component identical at both endpoints cannot determine , but its overall fraction must equal that common endpoint value.
For an original material-balance example, stipulate endpoint compositions and . With , the overall composition is . All three component calculations give . By contrast, still sums to one, but gives apparent phase fractions , and . Under the stipulated exact endpoints, it does not lie on this tie line. A ternary tie-line consistency residual records the failure of the vector balance; experimental use must account for composition uncertainties.
These chosen endpoints illustrate conservation, not a claim that an actual mixture has these equilibrium compositions. Establish endpoints from equilibrium measurements or a stable Gibbs free energy model. Moving along one liquid-liquid tie line changes phase amounts while preserving its endpoint compositions. Moving elsewhere in the two-phase region can select a different pair of endpoints; all tie lines need not be parallel. Finally, mole-based and mass-based diagrams require consistent fractions: a mole-based is not automatically a volume or mass fraction.
Tie-line endpoint covariance records how the measurement errors of the two measured liquid-liquid tie line endpoints vary together. Using independent mole fraction coordinates, represent the two endpoint estimates by column vectors . Their cross-covariance matrix is
An individual off-diagonal block need not be symmetric; the full joint covariance matrix must be a symmetric positive semidefinite matrix. The uncertainties of the two endpoint vectors alone do not determine their cross-covariance matrix.
Near an exactly balanced, interior tie-line phase-fraction fit, let be the row-vector sensitivity coefficient defined in tie-line phase-fraction sensitivity. If the overall composition measurement is independent of both endpoints, first-order uncertainty propagation gives
The cross term has a positive coefficient because the two endpoint perturbations enter the phase fraction with the same sign. Correlated endpoints can therefore increase the result. The general rule is to propagate the full joint covariance matrix, rather than assume that correlation always increases or always reduces uncertainty.[ref]
For a stipulated binary mixture example, use , , , so . Treat as exact and give each endpoint standard uncertainty with correlation coefficient . The lever rule yields
This gives for , about for , and for . These are first-order standard uncertainties under the stipulated joint error model, not bounds on all possible errors.
A shared calibration error affecting the overall composition as well changes the calculation. Suppose the same additive error affects identically. Then
The shared offset cancels exactly. More generally, a common affine map with also cancels in this binary ratio. This common affine calibration cancellation in the lever rule concerns only a truly common contribution; separate sample errors remain. If the shared offset has standard uncertainty , incorrectly treating its three appearances as independent would assign a spurious contribution instead of zero.
In general, stack the inputs as with joint covariance matrix . Let be the corresponding Jacobian matrix row from tie-line phase-fraction sensitivity, including its residual correction when needed. Then automatically includes correlations with the overall composition. The measurement guide specifically identifies common instruments, measurement standards and reference data as sources of such correlations.[ref]
An instructive measurement design analyzes the two equilibrium phases and the overall mixture using one instrument calibration, then repeats the entire procedure with independent instrument calibrations. The within-run contrasts and between-run changes probe different error contributions. Repeated readings under one unchanged instrument calibration cannot by themselves establish the uncertainty of its shared offset. The measurement model must identify which influences are common before the joint covariance matrix can represent them.
A tie-line phase-fraction fit estimates how much of each liquid phase is needed to reproduce an overall composition from specified liquid-liquid tie line endpoints. If are endpoint mole fraction vectors and is the mole-based phase fraction of phase , the mass balance predicts
The endpoints must be supplied by equilibrium measurements or a suitable thermodynamic model; fitting does not establish that an arbitrary pair of compositions is an equilibrium tie line.[ref]
For a ternary liquid-liquid tie line, use two independent composition coordinates, such as the first two mole fractions, since the third is fixed by their sum. Let be these two measured coordinates, the corresponding phase- coordinates, the difference between phase- and phase- coordinates, and a positive-definite covariance matrix for . With exact endpoints, generalized least squares minimizes
Differentiation yields the unconstrained estimate
The second expression imposes the physical bounds. It follows because is a convex quadratic when the endpoints differ in the measured coordinates. The ternary tie-line consistency residual then records the remaining failure of the mass balance.
For an original hypothetical example, take endpoint compositions and , with overall measurement . Suppose the first two measured mole fractions have independent standard measurement uncertainties and , so . Then
The predicted composition is , giving residual . The separate first- and second-component balances would suggest and ; the fit combines them according to their stated measurement uncertainties, rather than averaging those two numbers without regard to precision.
With Gaussian composition errors, fixed endpoints and an interior unconstrained fit, the tie-line phase-fraction uncertainty follows directly from the linear estimator:
for this example. Endpoint uncertainty, a fit on a boundary, or a nearly vanishing endpoint difference needs additional treatment. In particular, all three normalized mole fractions must not be treated as independent observations with an invertible three-coordinate covariance matrix: their exact closure creates dependence. A small fitted residual is evidence of consistency with the specified mass balance and error model, not a substitute for testing chemical potential equality or phase stability.
Tie-line phase-fraction sensitivity measures how an inferred phase fraction changes when the overall composition or the measured liquid-liquid tie line endpoints change. A sensitivity coefficient is a local partial derivative of the inference formula, rather than an uncertainty by itself. It becomes an uncertainty contribution only after combination with the input covariance matrix.[ref]
For one composition coordinate of a binary mixture, write the lever rule as
where are endpoint mole fractions, is the overall mole fraction and is the mole-based amount of phase . Differentiating the mass balance gives
Thus a measurement error in the overall composition and an equal measurement error in the phase- endpoint have different effects. The conditioning of tie-line phase-fraction inference deteriorates as the endpoint separation becomes small: the same composition measurement error then produces a larger change in the inferred phase fraction.
For an original example, take , , , giving . Increasing only by gives a first-order change . Direct substitution gives , a change of . For the closer endpoints , and balanced composition , the local sensitivity to the same endpoint error is ten times larger. This is a property of the inference geometry; it does not establish whether either hypothetical pair is in liquid-liquid equilibrium.
The multidimensional tie-line phase-fraction fit has an additional detail away from an exactly balanced composition. On independent mole fraction coordinates, hold a symmetric positive-definite matrix fixed and define
with distinct endpoints. Define row vectors and . Differentiating the generalized least squares normal equation gives
The residual correction in tie-line sensitivity vanishes when . Otherwise, moving an endpoint also rotates the fitted line relative to the nonzero ternary tie-line consistency residual. Omitting that contribution is an additional approximation. If itself changes with the measured inputs, its derivative must also enter the calculation.
These formulas describe the unconstrained fit locally. Imposing introduces boundary effects, and coincident endpoints make this inference undefined. A practical sensitivity check recomputes the fit after small positive and negative perturbations of one measured coordinate, keeping composition closure and the stated weight matrix. Agreement as the perturbation shrinks tests the derivative calculation; it does not validate the underlying equilibrium model.
Figure 1.
Closer tie-line endpoints amplify composition errors; endpoint correlation changes the inferred phase-fraction uncertainty
. Original binary examples with phase fraction0.40. Left: exact endpoint perturbations at separations0.60 and0.06. Right: first-order standard uncertainty with uncertain endpoints and exact overall composition; common calibration of all three measurements is a different model. Details.