Thermoelectric generator Created 2026-10-20 Updated 2026-11-05
A thermoelectric generator converts part of a heat flow driven by a temperature difference into electrical output through the Seebeck effect. Thermoelectric legs connect hot and cold sides; their electrical arrangement combines the generated voltages while their thermal paths carry heat between the sides.
A load draws electric current, so delivered power depends on both open-circuit voltage and internal resistance. Shorting the output gives current but zero terminal voltage, while an open circuit gives voltage but no useful delivered power. Thermal contacts and heat leakage alter the actual leg temperatures, so a material's thermoelectric figure of merit alone does not specify the complete generator's efficiency.
Thermoelectric offset 2026-11-05
A thermoelectric offset is an unwanted electric potential difference associated with Seebeck effect responses in a measurement circuit. Dissimilar conductors at different junction temperatures can generate a signal even when the intended electrical input is absent. Keithley's handbook discusses these offsets as a major limitation in low-voltage and low-resistance measurements.[ref]
For a simple two-material circuit, a useful model is
where the Seebeck coefficients depend on conductor material and temperature. With a stipulated constant difference and junction-temperature difference , the offset is . These are teaching inputs, not coefficients assigned to a particular real connector pair.
That small offset can dominate an intended signal. For an original resistor tested at , the wanted drop is also . An additive offset of the same sign doubles the indication to and gives an apparent if it is ignored. Reversing the current produces readings and in this model; their half-difference recovers the wanted .
Polarity reversal measurement cancels the unchanged offset, not every temperature effect. Thermal changes during the cycle can leave a residual, while current-induced heating can alter the resistor itself. The handbook therefore connects reversal timing with thermal stability.[ref]
An offset investigation records connector materials, junction temperatures, warm-up and handling, and compares readings before and after reversal. Reducing temperature gradients and avoiding unnecessary dissimilar-metal connections can reduce the generated signal. Keep residual correction uncertainty in the measurement result. A thermoelectric offset and random thermal noise have different roles in the measurement model; they are not interchangeable merely because both involve temperature.
Thermopile Created 2026-10-14 Updated 2026-10-18
A thermopile connects multiple thermocouples in series to turn a temperature difference into a larger electrical signal. Absorbed thermal radiation can heat its sensing junctions while reference junctions remain cooler; the signal depends on the thermal and optical design.
A thermopile is an array of thermocouples connected as a series circuit with their electromotive forces adding in the chosen terminal order. It measures a collective temperature difference through the Seebeck effect. An open-circuit electric potential difference requires no externally supplied electric current through the array: a high-input-electrical resistance voltmeter reads the signal. The heat that maintains the junction temperature difference still comes from somewhere, such as absorbed electromagnetic radiation.
In a membrane detector, an absorbing film heats the measuring junctions while reference junctions lie on the surrounding support. Actual junction temperatures can differ across the membrane.[ref] This converts difficult-to-observe heat transfer into an accessible electrical signal; the series connection combines many small contributions without requiring every thermocouple to have a separate meter.
Thermopile series voltage 2026-10-18
Use the A-positive terminal order of Seebeck effect for each thermocouple. Its thermocouple measuring junction has temperature and its reference connections have temperature . Define the difference of Seebeck coefficients as . Connect the B reference end of one thermocouple to the A reference end of the next at a common local temperature, so the terminal electric potential differences add:
The first A reference terminal is the positive meter input; the final B reference terminal is the negative input. Following this connected path and adding the individual Seebeck effect integrals proves the result. Matched meter leads with common endpoint temperatures cancel as in an isothermal terminal block. The manufacturer's sum formula also allows unequal individual contributions.[ref]
Figure 1. . Original idealized wiring, showing three of thermocouples. Each A leg rises from reference temperature to absorber temperature , and each B leg returns. B-to-A connections at join adjacent pairs; the thermally shared absorber and support do not short the electrically distinct junctions. A-positive and B-negative meter connections match the Seebeck effect convention. Arrows indicate absorbed electromagnetic radiation and escaping heat, not electric current. Details.
If all pairs share and the same nearly constant difference of Seebeck coefficients throughout that temperature interval, then
This is the pair's relative Seebeck coefficient, not either material's individual coefficient or a universal device constant. As an original constructed example, choose , and . Each thermocouple contributes and
Reversing the meter connections changes the sign. Exchanging and reverses the integrals and hence the electromotive force; this reversible sign response does not make a detector with heat conduction a reversible thermodynamic process. Reversing the wiring of one pair instead gives , because one contribution is subtracted rather than added. For this example the result is , and at equal junction temperatures every contribution vanishes.
The open-circuit condition matters. If the array's total electrical resistance is and the meter input has electrical resistance , the elementary voltage divider model gives . Thus is needed to suppress voltmeter loading. Appreciable electric current also permits Joule heating and the thermoelectric heat transfer to disturb the assumed junction temperatures.