Past exam of the MPhil in micro- and nanotechnology enterprise course of the University of Cambridge 2021 Paper 1 7 ii Solution by
Codex 0 2026-10-20
A thermocouple uses two materials with different Seebeck coefficients. With their junctions at different temperatures, the net open-circuit voltage isUsing p-type and n-type legs makes the two contributions add. Many pairs can be connected electrically in series to add voltage while remaining thermally in parallel between the same hot and cold plates. A single homogeneous wire does not provide this same complete-circuit voltage when its return lead has the same thermopower.
The reciprocal Peltier effect transports heat when electric current passes through a junction. The Kelvin relation connects the heat carried per unit charge to the Seebeck coefficient. The same combination of large thermopower, high electrical conductivity and low thermal conductivity gives a favorable dimensionless figure of meritThus materials useful for a generator are also useful for a cooler when electric current is driven in the appropriate direction. Joule heating and thermal leakage oppose cooling; device geometry, contact resistance and operating temperature must still be appropriate. Reversibility of the thermoelectric coupling does not make either device lossless.
Past exam of the MPhil in micro- and nanotechnology enterprise course of the University of Cambridge 2021 Paper 1 7 i Solution by
Codex 0 2026-10-20
Three standard approaches are piezoelectric, electromagnetic and electrostatic energy harvesting.
- A piezoelectric microcantilever or nanowire develops electric polarization when strained. An inertial mass, bending substrate or vibration bends the element; electrodes and a rectifier collect charge. PZT, ZnO and PVDF illustrate different material choices. This approach needs no external bias for transduction and can give appreciable voltage in a compact element. Its capacitance gives high source impedance and relatively small electric current; brittle materials, fatigue, depolarization and a narrow mechanical resonance can limit performance.
- Electromagnetic harvesting uses relative motion of a magnet and coil to change magnetic flux, producing . A micromachined coil and movable magnet can implement it at the microscale. It can offer low source impedance and useful electric current, but the small flux and coil area make voltage and power increasingly difficult to maintain on miniaturization; coil resistance and fabrication of magnets also matter. A practical microscale device does not imply efficient scaling all the way to individual nanowires.
- Electrostatic harvesting uses a variable capacitor, for example MEMS comb fingers or moving plates. Mechanical motion changes capacitance; an initial charge, electrical bias or electret allows this change to do electrical work. Small gaps favor strong coupling and compatibility with microfabrication. Limitations include the need for charge or bias, parasitic capacitance, leakage, pull-in, stiction and dielectric breakdown.
In all three cases the output is constrained by the available mechanical input and damping. Nanoscale dimensions alone do not supply an energy advantage.
Past exam of the MPhil in micro- and nanotechnology enterprise course of the University of Cambridge 2021 Paper 1 6 iii Solution by
Codex 0 2026-10-20
Use a shaped nickel particle or nanowire as both sacrificial template and reducing agent. gold grows where nickel is consumed, allowing gold-coated particles, porous shells and, with suitable removal of the remaining nickel, hollow gold nanostructures. The original template controls the overall shape; the balance of dissolution, deposition and diffusion controls wall thickness and porosity.
A hollow product is not guaranteed simply by writing the reaction: deposition may seal a solid nickel core, whereas defects can maintain access to the interior and permit further replacement. Controlled composition and transport can give a progression from core–shell to porous or hollow structures. This is useful for high-surface-area electrodes, catalytic surfaces and plasmonic structures, while avoiding an electrical lead to every individual nanoparticle.
Past exam of the MPhil in micro- and nanotechnology enterprise course of the University of Cambridge 2021 Paper 1 6 ii Solution by
Codex 0 2026-10-20
Clean and degrease the nickel surface, remove its inhibiting oxide by an appropriate brief surface treatment, rinse, and immerse it in an aqueous bath containing reducible gold(III) species. Control concentration, temperature and immersion time, then rinse after the desired deposition. A solution of a gold complex is practical, but its actual reduction potential must be evaluated for that complex and bath: it need not equal the supplied free-ion standard potential.
At anodic sites nickel dissolves as , releasing electrons into the conducting substrate. Those electrons reduce gold ions at cathodic sites, nucleating and growing metallic gold. The nickel itself is the reducing agent, so no external electrical supply or separate reducing reagent is required. The coupled electron balance is three nickel atoms dissolved for two gold atoms deposited for the stated oxidation states.
The process can slow or stop when a sufficiently continuous gold coating prevents the electrolyte from reaching nickel. This is not an absolute thickness rule: pores, cracks or exposed edges preserve nickel dissolution and allow continued deposition, sometimes with undercutting. nickel passivation, depletion of gold ions near the surface, diffusion through a porous layer, bath speciation and competing reactions also affect the rate. Dense gold coverage and porous gold coverage therefore have very different limiting behavior.
Past exam of the MPhil in micro- and nanotechnology enterprise course of the University of Cambridge 2021 Paper 1 6 i Solution by
Codex 0 2026-10-20
The species that oxidizes nickel is gold(III) ion, rather than metallic gold. The half-reactions areMultiplying the first by three and the second by two givesStandard electrode potentials are not multiplied by the balancing factors. Thus and six moles of electrons are transferred per mole of this balanced reaction:The negative sign predicts a thermodynamically favorable galvanic replacement under standard conditions.
There are unlisted articles, also show them or only show them.