Photon radiotherapy uses indirectly ionizing photons. Their Compton scattering, photoelectric effect and, at higher energy, pair production create charged particles that deposit energy. A megavoltage beam has a dose-build-up region followed by a gradual decline and substantial exit dose. Multiple shaped beams or intensity-modulated radiotherapy distribute this dose around a target.
Proton therapy uses directly ionizing charged particles with a finite particle range and a Bragg peak. Tuning beam energy controls depth and scanning controls lateral delivery; multiple energies cover a finite target thickness. Reduced distal and integral normal-tissue dose is a potential advantage. Limitations include range uncertainty, Multiple Coulomb scattering, nuclear secondary production, motion-dependent delivery, and a variable relative biological effectiveness, particularly near the distal edge. A physical dose advantage must be assessed against target coverage and clinically relevant toxicity; it does not by itself establish superior tumour control.
For photons, the total mass attenuation coefficient sums contributions from photoelectric absorption, Compton scattering, coherent Rayleigh scattering, and pair production in nuclear or electronic fields when above their thresholds. At sufficiently high photon energies, photonuclear reactions can also contribute. Attenuation counts removal from the incident narrow beam, including scattering without complete local deposition of the original energy.
In water at both specified energies, Compton scattering dominates. At , photoelectric absorption and coherent Rayleigh scattering make smaller contributions; at these are still less important. Nuclear-field pair production is impossible below , so it occurs in neither example. The positrons used to produce the fluorine-18 annihilation radiation do not change that threshold for interactions of its photons in water.
Strictly, is a linear attenuation coefficient, whereas is a mass attenuation coefficient; the source's wording blurs these units. The mass energy-absorption coefficient weights the fraction of incident photon energy transferred to charged particles and retained after radiative losses, rather than simply counting all removals. Coherent scattering contributes attenuation with negligible energy transfer. A photon deflected by Compton scattering can carry much of the original energy away. One often writes , with the fraction of secondary charged-particle kinetic energy lost radiatively. Under charged-particle equilibrium, multiplying photon energy fluence by gives the absorbed dose; that equilibrium condition matters near interfaces and in buildup regions.[ref]
A CT number is a dimensionless relative attenuation measure, conventionally . The X-ray spectrum used in computed tomography has an effective energy far below and is polychromatic. Its photoelectric absorption contribution depends strongly on composition, whereas water and soft-tissue attenuation at the positron emission tomography energy is mainly Compton scattering. Thus a CT number is neither a linear attenuation coefficient nor an energy-independent mass attenuation coefficient.
The usual conversion calibrates a piecewise linear or bilinear relation between CT numbers and . The air–water branch models predominantly density differences in lung and soft tissue; a separate water–bone branch accounts for the different energy dependence of mineralized tissue. The calibration depends on the computed tomography spectrum. After geometric registration, the resulting linear attenuation coefficient map is forward projected along each coincidence line of response to obtain . If a mass coefficient is stored, its conversion to a linear coefficient must also include mass density. Unusual high-atomic-number materials can violate the simple tissue calibration, so the conversion is a physical material model, not a universal arithmetic rescaling.[ref][ref]
For a megavoltage X-ray beam, the surface absorbed dose is below the subsurface maximum. Photons generate energetic secondary electrons, mainly through Compton scattering; the downstream electron fluence initially builds up until approximate charged-particle equilibrium is established. Beyond this buildup region, decreasing primary photon fluence, scattering and geometric spreading make the depth-dose curve fall gradually. A penetrating photon beam has a substantial exit dose.
A nearly monoenergetic proton beam deposits a moderate entrance dose, then a sharp Bragg peak near the end of its range. As nonrelativistic protons slow, their electronic stopping power rises approximately as over the relevant part of the track. Once the protons stop, the dose falls steeply. Range straggling and energy spread broaden the peak; nuclear interactions add a smaller nonideal tail, so an exact hard cutoff is an idealization. Superposing appropriate incident energies produces a spread-out Bragg peak covering an extended target.[ref]
The label MV for an X-ray treatment beam specifies the nominal accelerating potential of the electron accelerator. Its bremsstrahlung beam is a broad photon energy spectrum with an endpoint of order , not a monoenergetic beam whose individual photons all carry the quoted numerical energy. Proton therapy beam energies can instead be specified directly in MeV per incident proton.
Figure 1.
Qualitative photon and proton depth-dose profiles and functions of passive proton beam modifiers
. Details.
Let be the incident laser-photon energy and . The maximum in the usual soft-laser geometry occurs for a head-on encounter followed by a forward outgoing photon along the electron beam. Boost into the initial electron rest frame: the incident energy becomes . Backscattering there gives the Compton scattering recoil relation . Boosting this outgoing photon forward to the lab gives
The familiar limit additionally requires and . The denominator is the recoil correction, not an optional factor at arbitrary incident energy.
For completeness, if the incidence direction is prescribed rather than optimized, let its unit vector be and the outgoing direction . Squaring the residual electron four-momentum on its mass shell gives the more general kinematic relation
Thus an unspecified crossing angle must not silently be identified with head-on incidence; the boxed result is the maximum for the stated head-on soft-photon arrangement.
Numerically gives , and a photon has energy . The maximum scattered energy is , giving
The rest-frame incident photon is only about one electronvolt, so the small recoil correction is consistent with the amplification estimate.
Three relevant observable effects are the relativistic Doppler effect in spectral-line shifts, including the transverse time-dilation contribution; relativistic aberration, observable as a change of apparent light direction with observer motion; and relativistic beaming of moving emitters, associated with strongly asymmetric jet brightness. Apparent superluminal motion supplies a related light-travel-time test: can exceed one without a material speed exceeding . These interpretations require an emission and source-motion model; a cosmological or gravitational redshift by itself is not a direct test of special-relativistic kinematics.
For Compton scattering from an initially stationary electron, let incoming and outgoing photon energies be and and their mutual angle be . Four-momentum conservation gives . Squaring and using both electron mass shells and both photon null norms gives
Consequently the outgoing angular frequency and shift are
Equivalently, the Compton wavelength shift is . The electron recoil is essential; treating its energy as unchanged would suppress the effect.
Let and . For a head-on photon and particle collision, boost to the particle's initial rest frame. The incident photon energy is . On the inverse-Compton branch , the maximal outgoing lab energy corresponds to rest-frame backscattering into the particle's forward direction. The exact Compton scattering recoil formula gives . Boosting the backscattered photon back to the lab gives
For this becomes
Only in the additional Thomson scattering limit may the denominator be neglected, yielding the printed estimate . Ultrarelativistic motion alone does not justify it. For example and would give from that estimate, exceeding the available total energy; the recoil-corrected maximum is about .
For an arbitrarily hard incident photon, maximizing over direction needs a further qualification: if , the largest outgoing photon energy is the unchanged , rather than this amplified backscattering branch. The exact photon energy gain is . Calling the outgoing energy the gain is accurate only when amplification is large. These distinctions prevent the inverse Compton scattering estimate from violating conservation of energy outside its low-rest-frame-photon-energy regime.
Photoelectric absorption 2026-10-25
A photon transfers its energy to a bound electron, ejecting it if energetically allowed. Subsequent atomic relaxation can emit characteristic radiation or additional electrons. Its material and energy dependence differs from Compton scattering, which matters when converting computed tomography attenuation to the higher photon energy of positron emission tomography.
Photon absorption 2026-10-06
Photon absorption removes a photon and transfers its energy and momentum to matter. It contributes a negative photon-number collision source. It differs from Compton scattering, which redistributes a photon's energy and direction while preserving the count. The integrated source can vanish if photon emission and absorption balance.
A single recoil endpoint leaves a tradeoff between incident speed and projectile mass. Two targets can remove the unknown incident speed. Assume both runs sample the same maximum projectile speed and that single elastic collisions reach the endpoint. For initially stationary target masses , let their maximum recoil speeds be . The maximum elastic recoil energy fraction calculation gives
If energies rather than speeds are inferred, use . The energy ratio itself is not the speed ratio.
For the stipulated example, hydrogen and nitrogen give
The inferred mass then determines . Changing the assumed mass to improve one recoil endpoint changes the prediction for the other: this is the constraining power of the comparison.
James Chadwick's June paper instead used approximate endpoints and , obtaining ; it allowed roughly ten percent uncertainty in . This was a rough mass comparison.[ref]
The inverse calculation has useful built-in checks. A positive finite mass requires . As approaches , distinguishing large projectile masses becomes difficult. Differentiation gives
Uncertain recoil endpoints therefore produce an uncertain inferred mass; the collision model cannot turn imprecise range measurements into exact spectroscopy. If different target runs select different incident energy groups, the common- cancellation also fails.
For comparison, Compton scattering of a photon of energy from a stationary free target of mass has the exact relativistic endpoint
This follows by combining momentum conservation with the target's relativistic energy, maximizing transfer when the photon reverses direction. Unlike the massive-projectile calculation, this equation does not approximate the incident photon as a nonrelativistic particle.
As a separate, explicitly hypothetical test, take and target rest energies and . To reproduce the stipulated hydrogen recoil endpoint , the photon would need . The same photon would give the heavier target at most , whereas the stipulated massive projectile gave . This is the structure of a two-target discrimination, not a transcription of a 1932 measurement. Actual radiation can contain more than one energy group or both photons and neutrons; a useful model must account for the observed endpoints and their origin together.
Each elementary QED vertex has one photon leg, so counting these legs gives . An amplitude with two external photons has even . In particular Compton scattering has no cubic-order elementary-vertex contribution. With four external legs and , a connected diagram has four internal lines and one loop.