Temporal summation 2026-10-14
Temporal summation is overlap of responses to inputs arriving at different times. It can occur at one repeatedly activated synapse or across several synapses; it is not defined by reuse of a particular contact. For prescribed electric current inputs in a passive compartment, residual depolarization from earlier pulses changes the voltage reached by later pulses. The membrane time constant sets how rapidly that residual decays, while the duration of synaptic conductance and spatial filtering by a passive dendritic cable can add other timescales.
For the diagram, write , choose inward-positive imposed electric current , and use the ordinary differential equationA rectangular pulse of amplitude and duration , starting from rest, ends withAfterwards its contribution decays as . The superposition principle therefore gives, at the end of the third pulse with onset spacing ,For this is , so the peak membrane potential is . For it is , giving . Both protocols inject of electric charge; equal charge does not imply equal peak voltage because the leak drains charge while it is delivered.
In the adjacent-pulse case, the illustrative neuronal firing threshold is crossed at . A leaky integrate-and-fire model would emit its first event there and reset, so its later trajectory would differ from the passive diagram. The widely spaced train never reaches that threshold. Thus changing input timing alone can change whether an event occurs. A real neuron's neuronal firing threshold is also state-dependent, and synaptic conductance pulses are not prescribed electric current pulses.[ref]
Measured responses to repeated presynaptic action potentials may also change through synaptic plasticity. A larger second response can therefore reflect a stronger second input as well as residual postsynaptic voltage. To isolate passive temporal summation, compare known injected electric current waveforms with their single-pulse responses under stable recording conditions; to test actual synapses, measure whether input efficacy changes. These are proposed discriminating comparisons, not additional controls claimed for the slice experiment.[ref]
Two-state ion-channel gating Created 2026-10-14 Updated 2026-10-14
Two-state ion-channel gating models an individual gate as a random switch between closed and open states. Write for its open probability; this is the in the header equation. An individual gate's state is always closed or open, rather than partly open. A population of identical gates can have a fraction open near , and averaging repeated identically prepared trials estimates the same probability. A finite population's observed fraction fluctuates. See Purves and colleagues, Neuroscience, 2nd edition (2001): Ion Channels Underlying Action Potentials for single-channel steps and their population averages.
At fixed membrane potential , let constant rates govern closed-to-open and open-to-closed transitions respectively, in . This is a two-state continuous-time Markov chain. Over a short interval , an initially closed gate opens with probability , and an initially open gate closes with probability . Gain minus loss gives the deterministic ordinary differential equation for the probability:Here is the fixed-voltage limiting open probability, and is a time constant. The ratio of the rates fixes the limit, while their sum fixes the speed. With initial probability ,For a short derivation, subtract : the deviation obeys , yielding the exponential function. After one time constant, of the initial deviation remains. The solution stays between and , so it remains a valid probability. The rate and time constant formulations are described in Gerstner and colleagues, Neuronal Dynamics, §2.2.2: transition rates and channel kinetics.
For a worked toy condition A, choose and . Then , , andIn a separately prepared condition B, choose , and the same . Now , , and . Condition B approaches a higher limit more quickly. These are two stipulated constant-rate conditions with held fixed in each experiment, not an empirical function relating rates to voltage or a sequential switch between conditions. The initial need not be the limiting probability at the newly imposed voltage.
Two-state ion-channel gating: two constant-rate relaxation conditions
. Original computed probability curves, both starting at . Dashed lines show the limiting open probabilities and ; dotted lines mark time constants and . The dot marks condition A at , where . Smooth curves represent open probability or population averages, not an individual gate's random state trace or an ionic electric current. Details.In the Hodgkin-Huxley model, the rates depend on membrane potential: and . Its is the limit for voltage held at that . During an action potential, changing changes the rates and gates feed back onto through ionic electric currents; substituting the present voltage into the constant-rate solution does not solve that coupled system. Gating describes availability of a conducting pathway. Even an open ion channel carries zero net ionic electric current at its reversal potential.
The useful bridge is from abrupt random molecular events to a smooth population prediction. A channel requiring several independent permissive gates in an ion channel has an open probability equal to their product; this can make channel availability much smaller than each gate's availability. The Hodgkin-Huxley model uses and for sodium and potassium electrical conductances, respectively.
Voltage clamp Created 2026-10-13 Updated 2026-10-14
A voltage clamp uses electrical feedback to hold a preparation's membrane potential near a commanded value while measuring the electric current required to maintain it. Holding voltage separates changes in electrical conductance from changes in electrical driving force. Imperfect voltage control and finite recording bandwidth limit the inference. The muscle experiment under ionotropic receptor used separate intracellular electrodes for voltage control and a sealed patch pipette for recording local electric current.[ref]
Voltage-gated ion channel 2026-10-13
A membrane channel whose opening depends on membrane potential. Regenerative activation and subsequent inactivation or opposing currents help produce an action potential.
Whole-cell recording 2026-10-13
Whole-cell recording establishes intracellular electrical access by rupturing the membrane under a sealed patch pipette while retaining the gigaohm seal. Under adequate voltage clamp, the measured electric current combines contributions from accessible ion channels, membrane capacitance and seal leak current. Current clamp instead follows membrane potential while supplying a chosen electric current. Whole-cell recording is useful for linking a biological cell's total electrical response to its ion channels, but neither mode automatically controls distant dendrites or preserves the original cytosol.
In the 1981 methods demonstration, a bovine chromaffin biological cell was tested before and after patch rupture. Small voltage clamp steps produced a much larger capacitive transient after break-in. Integrating it gave for a cell; its decay indicated patch-clamp series resistance below . Depolarizing commands then revealed ionic electric currents. Separate current clamp recordings showed spontaneous action potentials. The comparison established access to the cell interior, rather than a claim that every pipette command equals membrane potential. Slower transients sometimes indicated incomplete rupture, and these small-cell results do not establish spatial control of a branched neuron.[ref]
Improved patch-clamp techniques for high-resolution current recording from cells and cell-free membrane patches by O. P. Hamill and others. pp. 98–99, Figure 15 and following voltage-clamp and current-clamp discussion
Synthetic whole-cell recording: patch-clamp series resistance and passive responses
. An original equivalent electrical circuit uses , and . The current clamp step and voltage clamp step are separate synthetic experiments. The passive model omits active ion channels, seal leak current, pipette capacitance and amplifier dynamics. Curves are calculations, not experimental measurements. Details.