Barnett response of a magnetic material 2026-10-18
The two-state calculation is not a general formula for a ferromagnet. Exchange interactions, magnetic domains, magnetic domain-wall pinning, magnetic anisotropy, and hysteresis can determine which response is accessible. Both spin angular momentum and orbital angular momentum can contribute; a single constant gyromagnetic ratio may be only a restricted effective description. Rotation sets an internal bias, while the material and its preparation determine magnetization. The Barkhausen effect illustrates why a smooth bias can produce jumps instead of the toy smooth curve.
For a limited, reversible, isotropic linear model, suppose the same intrinsic volume magnetic susceptibility responds to the applied bias and to . For a uniformly magnetized ellipsoid along a principal axis, include its demagnetizing factor :Solving this linear equation yieldsHere and are actual magnetic field intensities; the added rotational bias is an equivalent drive in the constitutive response. In SI, dimensionless multiplies an intensity in , so would omit and have the wrong units. A susceptibility defined instead as has different units. State the convention before comparing formulas.
At zero applied magnetic field intensity, a stipulated gives prefactor in a sphere, with , and a prefactor approaching in a long axial ellipsoid. This is a geometry check of the assumed linear model. A real cylinder does not have an exactly uniform demagnetizing field, and an irreversible ferromagnet cannot in general be represented by this single linear equation. Inferring an intrinsic gyromagnetic ratio requires an independently calibrated material response and a geometry-dependent conversion of the measured stray magnetic field.
Differential magnetic susceptibility 2026-10-14
Differential magnetic susceptibility is the local slope at a specified bias magnetic field intensity, holding temperature and other stated constraints fixed. It equals volume magnetic susceptibility only for a linear response through the origin. For example, has , but , where . At these are about and times their common zero-field slope. A finite sweep chord is another quantity, not automatically this derivative.
If the differentiated field is instead the internal magnetic flux density, the longitudinal chain rule applied to givesThis differs from the vacuum/applied- conversion in volume magnetic susceptibility. It assumes a differentiable single branch with locally invertible .
In vacuum, magnetization is zero and magnetic flux density obeys . The applied quantities and mean the field of the external sources at the sample position with the sample absent. The internal magnetic field intensity includes the sample's demagnetizing field; its internal magnetic flux density additionally includes . A field quoted in the tesla is a quantity, even when an instrument informally calls it “”.
For a uniformly magnetized ellipsoid, along a principal axis with demagnetizing factor in the International System of Units,For a sphere, . The axial value approaches zero in the long slender ellipsoid limit and the normal value approaches one in the thin flat ellipsoid limit. Thus a stipulated intrinsic volume magnetic susceptibility would yield apparent values in a sphere and approximately in a long axial sample. These are calculated geometry effects, not measured material values. For fixed , implicit differentiation gives the same conversion for local differential magnetic susceptibility, .
Gouy balance 2026-10-14
A Gouy balance detects the force exerted by a nonuniform magnetic field on a sample of uniform cross-section extending between high- and low-field regions. TeachSpin's implementation reverses the usual arrangement: a rare-earth permanent-magnet assembly sits on a one-pan electronic balance, while a separate holder brings the sample into the field. The magnet's apparent mass change measures the opposite of the sample's vertical force, by Newton's third law. The described pole faces have diameter and separation ; samples occupy cuvettes of cross-section and height about . [ref]
Foundational Magnetic Susceptibility by TeachSpin. TeachSpin, Foundational Magnetic Susceptibility, Instrument: The Gouy Method and “Weighing the magnet” method; Specifications: magnet and sample dimensions
The same balance calibrates magnetic flux density by measuring the reaction force on the magnet when a wire of known horizontal length carries known electric current perpendicular to the field: . The manufacturer describes water being repelled by the high-field region, identifying negative magnetic susceptibility. This observed sign supplies a qualitative test, not a measured Curie's law curve. [ref]
Foundational Magnetic Susceptibility by TeachSpin. TeachSpin, Foundational Magnetic Susceptibility, Instrument: Absolute calibration method and Diamagnetism
For weak reversible linear response, a uniform sample displacing a weakly magnetic surrounding medium has, to leading order, downward forceThis follows by integrating the induced-dipole force density along a downward coordinate. is the cross-sectional area, and the two values are applied magnetic flux densities. The force depends on the endpoint fields; the entire field-gradient profile need not be measured under these assumptions. In the reversed apparatus, after subtracting the holder background, where is gravitational acceleration. This sign must be reversed before inferring volume magnetic susceptibility.
Useful controls are an empty-holder reading at the same position, a distant-sample baseline, repeated wire-current reversals during field calibration, and stable temperature. They separate holder response, balance drift, force offsets, and thermal changes; these are proposed checks for the stated inference. Finite endpoint fields, nonuniform cross-section, uneven powder packing, stray forces and a demagnetizing field limit the simple formula. If magnetization is nonlinear, the weak-response force involves instead of a constant- endpoint square. A balance reading then measures an integrated response, not directly the local differential magnetic susceptibility.
Larmor-Langevin susceptibility 2026-10-25
The dimensionless SI volume magnetic susceptibility of number density of independent spherical bound electrons with mass and electron-weighted mean-square orbital radius. In a uniform magnetic field, the quadratic minimal-coupling Hamiltonian gives . Spherical symmetry gives ; differentiating twice with respect to gives the displayed negative response. Atomic orbitals use the bare electron mass, whereas a shallow donor envelope within an effective mass approximation uses that envelope's effective mass.
Magnetic susceptibility Created 2026-09-24 Updated 2026-10-13
Magnetic susceptibility describes how readily a magnetic field changes a material's magnetization. The field variable and normalization matter: volume magnetic susceptibility in the International System of Units is dimensionless, whereas a derivative of total magnetic moment with respect to has units of . A slope measured against the applied magnetic field intensity also depends on the sample's demagnetizing field.
For an isotropic, reversible linear response through the origin, writeHere is magnetization, or magnetic moment per volume; is the internal magnetic field intensity; is the internal magnetic flux density; and is the vacuum permeability. Both and have units . The magnetic permeability is . [ref]
Magnetic susceptibility and permeability. Richard Fitzpatrick, Magnetic susceptibility and permeability, equations (866)–(868): isotropic linear response and permeability
The independent-moment magnetic response below shows why one number cannot describe every field: magnetization approaches a saturation magnetization, while its differential magnetic susceptibility approaches zero. Anisotropy requires a magnetic susceptibility tensor; hysteresis requires specifying the preparation and sweep branch as well as the bias magnetic field, temperature, and timescale. The Gouy balance turns a small response into a measurable force without presuming that its readout is already the intrinsic volume magnetic susceptibility.
Molar magnetic susceptibility 2026-10-24
The product of volume magnetic susceptibility and molar volume. In SI it has units . For one localized magnetic ion per formula unit, its Curie–Weiss law is , with . Normalization per mole of formula units and per mole of magnetic ions differ when there is more than one such ion per formula unit.
Past exam of the condensed matter physics course of the University of Oxford 2016 3 a Solution 2026-10-25
Write the two allowed moment projections as , where for spin one-half. Their Zeeman energies in the prescribed flux density are . The single-particle partition function and the mean moment along the field areFor noninteracting moments, magnetization is moment per volume:For electron-like spin-only moments , these become and .
Differentiate with respect to the specified to obtainThis derivative is not a dimensionless SI volume susceptibility. In the weak-feedback approximation , the usual dimensionless differential susceptibility is . The small-field limit gives Curie's law . At finite bias a secant response differs from the differential slope . For an internal retained self-consistently, the exact local conversion is ; demagnetizing geometry can further affect an applied-field measurement. Stating the field convention avoids a hidden factor of or confusion between a slope and a ratio.
Past exam of the condensed matter physics course of the University of Oxford 2016 3 b Solution 2026-10-25
A shell has one hole in the otherwise filled shell. Hund's rules give , , and, for a more-than-half-filled shell, : the free-ion term is . Its Landé factor isDistinguish the Curie effective moment from a saturated projection:The question then explicitly asks us to use orbital quenching in the crystal. Ligand fields split and mix orbital states, suppressing their freely orientable angular momentum. The spin-only approximation has , , so but the two field-axis projections are . The latter, not , belong in the tanh argument and saturation magnetization.
The sulfate and water environment supplies mainly closed-shell, weakly magnetic surroundings, stabilizes localized Cu2+ sites and separates their moments so that exchange can be weak on the temperature scale considered. Paramagnetism here is an approximation of weakly interacting local spins, not a claim that dilution guarantees no magnetic ordering at any temperature. Elemental copper has a filled band and itinerant conduction electrons rather than one localized Cu2+ spin per atom. Pauli spin response and orbital/core contributions then replace a local-spin Curie law; ordinary pure copper has a weak net diamagnetic response.[ref]
https://www.sciencedirect.com/science/article/pii/S1090780715000774. 2015 primary measurement, abstract: negative volume susceptibility of high-purity copper wire
There is one Cu2+ per formula unit, hence m. The spin-only weak-field SI volume susceptibility isThese neglect exchange, anisotropic factors and background diamagnetism. At high field and low temperature, saturation requires the nonlinear response in a; a field-independent Curie value then describes only the zero-field slope.
Past exam of the condensed matter physics course of the University of Oxford 2021 4 b Solution 2026-10-25
The number of formula units per volume follows from the mass density:Each neutral formula unit contains electrons, so . Let be the electron-weighted mean-square orbital radius, averaged over all these electrons. The supplied Larmor-Langevin susceptibility then gives the dimensionless SI volume magnetic susceptibilitywhere is the Bohr radius. An explicit rough atomic-scale assumption gives .
The quoted bulk data do not determine : a nuclear charge does not specify an orbital radius in a screened many-electron chemical atom. Consequently the numerical estimate just made has atomic-model uncertainty; it is not a deduction with guaranteed 30 percent accuracy. For example, the alternative assumed gives four times the magnitude while leaving every supplied bulk number unchanged. Atomic wavefunctions, an explicit screened-orbital model, or measured atomic magnetic susceptibilities of materials exhibiting diamagnetism would be needed to support that accuracy. Keeping explicit makes the later comparison independent of an unadvertised radius assumption. The bare electron mass belongs in this atomic formula; the conduction band effective mass is relevant instead to the large donor envelope in part (c).
Past exam of the condensed matter physics course of the University of Oxford 2022 4 b i Solution 2026-10-25
In weak magnetic field and the regime of paramagnetism, localized magnetic moments with total angular momentum and Landé g-factor have SI volume magnetic susceptibilitywithin the Curie–Weiss law. Here counts magnetic ions per volume, is the vacuum permeability, is the Bohr magneton, and is the Weiss temperature. The factor is the zero-field average of the squared angular projection over .
For one magnetic ion per formula unit, a molar volume contains magnetic ions, where is the Avogadro constant. Consequently , and the molar magnetic susceptibility isDefining the dimensionless effective paramagnetic moment by , numerical substitution givesThe normalization is per mole of formula units, which here also means per mole of magnetic ions.
At weak field or high temperature, and , soUsing for the applied-field response and neglecting demagnetizing corrections, the SI volume magnetic susceptibility isThis is Curie's law. If susceptibility is instead defined as , its Curie constant is without ; stating which field is used prevents a units error.
Volume magnetic susceptibility 2026-10-14
Volume magnetic susceptibility is the dimensionless ratio of longitudinal magnetization to internal magnetic field intensity in a linear regime through the origin. Positive response gives paramagnetism. Always distinguish magnetization from total magnetic moment : dividing by volume changes the normalization. Mass-normalized and mole-normalized values likewise require the mass density or the volume per amount of substance before comparison with .
In the existing Pauli paramagnetism formula, denotes total magnetic moment, and is the total spin-summed density of states. Relabel that response asHere is the Bohr magneton. If its is a prescribed vacuum/applied magnetic flux density , the dimensionless apparent slope is . It agrees approximately with intrinsic only when the demagnetizing field correction and magnetic feedback are negligible. The existing Curie's law formula also uses a total-magnetic moment, -derivative convention; its counts moments rather than giving a number density.