A full reversal leaves saturated isotropic magnetostrictive strain unchanged. A rotation generally changes it. In the simplest unconstrained orientation average over magnetic domains, replace by , not by . Equal populations pointing along and have zero net magnetization but the same preferred strain as a single domain along . An isotropic orientation distribution instead has and zero average preferred strain. Elastic compatibility between real magnetic domains can modify the macroscopic response.
Reversing an applied magnetic field does not guarantee that all microscopic orientations retrace the same path. Hysteresis, magnetic domain-wall pinning, and changes in domain populations can alter the measured curve. The reversal identity concerns the same pair of magnetic states with opposite local magnetization; it is not a universal prediction that an arbitrary experimental sweep is a single-valued even function of applied magnetic field.
Magnetoelastic coupling 2026-10-18
Magnetoelastic coupling links a material's magnetic state to its strain and stress. Magnetostriction describes a resulting deformation; mechanical loading can also change the magnetic state.
Magnetostriction Created 2026-10-14 Updated 2026-10-18
Magnetostriction is a change of a material's shape or dimensions associated with its magnetization. A magnetic field can therefore produce strain without a contact force. The resulting magnetoelastic coupling lets a ferromagnet convert changes of magnetic state into mechanical motion; a constraint can instead turn the preferred deformation into stress. James Prescott Joule published his study of iron and steel bars in 1847.[ref]
The surprising point is that reversing the magnetization need not reverse the deformation. A material can prefer a longer axis along either or : an axis has no arrow. Isotropic linear magnetostriction vanishes excludes one particular linear constitutive term, while saturated isotropic magnetostrictive strain supplies a nonzero response with a quadratic dependence on the magnetic direction. The pulsed-field optical magnetostriction experiment shows how an actual length change can be resolved, and quadratic magnetostriction and frequency doubling separates an illustrative response law from a measured material curve.
Magnetostrictive strain 2026-10-18
Magnetostrictive strain is the preferred strain associated with a specified magnetic state relative to a stated reference. The measured strain also depends on mechanical constraints.
Mathias Doerr Created 2026-10-18 Updated 2026-11-05
Mathias Doerr coauthored a magnetostriction measurement system using Fibre Bragg gratings as optical strain gauges. The apparatus measured small samples in pulsed magnetic fields, resolving strain of order with a -kHz bandwidth at low temperatures.[ref]
Maxwell dissipation under controlled stress and strain Created 2026-10-20 Updated 2026-11-05
For a series Maxwell model with , . At fixed strain amplitude the energy dissipated per cycle is and peaks at . At fixed stress amplitude it is instead , which has no finite-frequency maximum. Specifying the imposed variable and whether loss means energy per cycle or power is essential.
Michael Nicklas Created 2026-10-18 Updated 2026-11-05
A researcher whose team used fiber Bragg gratings to measure magnetostriction of small single-crystal specimens. Bonding the fiber sensor to a sample transfers its strain into an optical wavelength shift. The apparatus makes structural responses accessible under short, strong magnetic field pulses and cryogenic conditions.[ref]
Minimum potential energy principle in elasticity Created 2026-10-14 Updated 2026-10-25
Let a convex strain energy density have derivative equal to the actual stress tensor. Under mixed displacement and traction data, any equilibrated stress with the prescribed body force and boundary tractions represents the external work. For any compatible trial strain , the convex supporting-plane inequality gives . The integral of vanishes by integration by parts. Thus the actual strain minimizes .
Neisseria 2026-11-05
Neisseria is a genus of bacteria containing both disease-associated species and species that commonly inhabit human mucosal surfaces without causing the corresponding disease. Neisseria gonorrhoeae is one pathogenic member; the behaviour of one species should not be assigned automatically to the entire genus.
Comparative genome sequencing found substantial sharing of genetic variants between human-associated commensal and pathogenic Neisseria. [ref] This makes the genus useful for studying how a shared genetic background interacts with host association. Possession of a gene associated with disease in another strain does not by itself establish that its new host has the same disease-causing phenotype.
Neisseria gonorrhoeae 2026-11-05
Neisseria gonorrhoeae is the bacterium causing gonorrhoea, an infection of mucosal surfaces that can also produce complications beyond the original site. Some infections cause few recognizable symptoms, so symptom frequency and infection frequency need not coincide. [ref]
It belongs to Neisseria, a genus that also includes human-associated commensal species. Shared ancestry therefore does not mean identical interactions with a host. Comparing genomes across the genus reveals genetic exchange, but the clinical behaviour of a strain depends on the organization and regulation of its genome as well as on host and tissue context. The disease name identifies a clinical entity; the species name identifies an organism.
Neutral axis 2026-10-18
The neutral axis is the line in the cross-section of an elastic beam where longitudinal bending strain vanishes. For a homogeneous beam in pure bending, zero resultant longitudinal force gives , so the neutral axis passes through the centroid. Fibres on its opposite sides are stretched and compressed. The second moment of area about this axis controls the relation between bending moment and curvature.
Nonnegative isotropic elastic strain energy Created 2026-10-14 Updated 2026-11-05
In three-dimensional isotropic linear elasticity, decompose the symmetric strain as with and . The stored energy is . Its nonnegativity for every strain is equivalent to the displayed inequalities: the traceless and purely volumetric test strains prove necessity, and the sum of squares proves sufficiency.
Normal strain Created 2026-10-20 Updated 2026-11-05
The fractional change in the length of a material line in a specified direction. For infinitesimal deformation with unit direction , it is , where is the small strain tensor.
Overhung shaft bending stress is the longitudinal normal stress caused by the bending moment from a transverse load beyond the shaft's supports. It differs from twisting due to shaft-axis torque. In the ideal two-support model, the largest overhung shaft bending moment has magnitude , where is the end load and the overhang.[ref]
For a homogeneous linear elastic beam, plane sections in the beam model give longitudinal strain relative to the neutral axis. With Young's modulus ,
where is the second moment of area. Thus . For a solid circular shaft of diameter , and the outermost distance is , giving
An original example uses , and . Then and . Reducing diameter to multiplies nominal stress by , raising it to about . The cubic diameter dependence makes a diameter change different from an equal percentage change in overhang.
A measurement check can place opposed axial strain gauges at one shaft station. In a simple axial-plus-bending model, readings and microstrain give axial strain microstrain and bending strain microstrain. This separates two contributions that a single gauge would mix.
The nominal formula excludes local geometric concentrations, multiaxial loading and yielding. It is not a fatigue-life prediction. Under a stationary bending direction, a rotating material point can experience alternating stress, motivating rotating shaft bending fatigue even when the external load is steady. A permissible load requires the actual geometry, material and load history.
Papillary muscle 2026-11-05
A papillary muscle is a muscular projection inside a ventricle that anchors chordae tendineae attached to the mitral valve or tricuspid valve. During ventricular systole, its contraction helps maintain the supporting geometry and tension that restrain the valve leaflets. Valve opening is driven by the appropriate pressure difference; a papillary muscle does not act as a cord-operated opener.[ref]
The anchor's position matters as well as its ability to contract. In a primary simulator study, investigators examined six human and five porcine specimens of the mitral valve, measuring six selected chordae tendineae with force transducers. Eight tested anchor configurations used 5 mm displacement components relative to a reference position. The resulting tension changes depended on which chord was measured.[ref] Moving an anchor therefore need not distribute extra load equally through the apparatus.
An original mechanical approximation illustrates the distinction. If a taut cord has reference length , cross-sectional area and effective Young's modulus , a small extra extension gives
This is a local Hooke's law approximation, not a claim that biological cords remain linear at every strain. Anchor displacement changes the cord's extension and direction, while active muscle contraction changes the moving support itself. In the equal-tether example under chordae tendineae, changing direction also changes the tension needed to balance a fixed leaflet load. The apparatus is consequently a coupled geometrical and muscular system; naming its parts alone does not predict its forces.
Passivity in linear viscoelasticity Created 2026-10-18 Updated 2026-11-05
A passive viscoelasticity law cannot deliver net work in a periodic steady deformation without an external source of energy. With strain and stress , the cycle-averaged supplied power is . Thus a necessary passivity condition, using the convention , is a nonnegative loss modulus at every positive frequency. Equivalently the work per cycle is . A stable differential equation for stress does not by itself ensure this energetic condition.
The in-plane equilibrium equations are and . On a simply connected patch, each divergence-free row has a streamfunction: write , , . Symmetry gives , so another potential exists with , . Hence
If two such Airy stress functions give the same stress, their difference has zero Hessian and is therefore an arbitrary affine function on a connected domain. This is the full nonuniqueness for a fixed stress. The existence argument is local, or global on a simply connected domain; domains that are multiply connected regions require the associated force and moment period conditions for a single-valued global potential. Equilibrium alone should not silently erase that topological qualification.
For plane strain put . The constitutive equation gives . Consequently
The displacement Saint-Venant compatibility equations then becomes
For stable elastic moduli the coefficient is nonzero, so . If is bounded and smooth and on its boundary, integrating twice by parts gives . Thus is harmonic with zero boundary value and by uniqueness of the Dirichlet problem. The normal-derivative condition is what removes the extra fourth-order boundary terms.
For the pressurized annulus, substituting the radial constitutive equations into equilibrium gives , so . The stresses are
Using gauge stresses relative to ambient, the boundaries are , . Therefore
and
The maximum occurs at the bore. Once the chosen yield criterion is reached, Hooke's law cannot describe the total strain alone: write total strain as elastic plus plastic strain and supplement the elastic stress law with a yield condition, a plastic flow rule and any required work hardening law. A plastic region starts near the bore and must be matched to the remaining elastic region. The exact conversion between a principal-stress difference and the quoted yield stress depends on whether the material criterion is Tresca or von Mises. This is the elastic stress concentration in a pressurized thick cylinder.
Write , and . Differentiating twice and cancelling the mixed partial derivatives gives
A convenient set of six three-dimensional Saint-Venant compatibility equations is
They follow by inserting and commuting derivatives. They form the six symmetric components of the incompatibility tensor , up to the indicated signs and permutation of components.
They obey the three differential identities , because a symmetric pair of derivatives contracts with an antisymmetric Levi-Civita symbol. Thus there are three independent differential constraints, represented symmetrically by six component equations; they are not six unrelated constraints on the six strain functions. For example, at a nonzero wavevector directed along the third axis, compatibility imposes while can arise from the three displacement components. This confirms rank three. One cannot simply discard the same arbitrary three component equations in every direction; their independence is differential, with the stated identities. On a simply connected domain these are the local Saint-Venant compatibility equations for strain to be a symmetric displacement gradient, while domains that are multiply connected regions require global closure conditions as in the screw example. This is Saint-Venant strain compatibility and differential identities.
For antiplane displacement the only nonzero strain components are and . Commutation of mixed partial derivatives gives the necessary local compatibility condition
The supplied stress is symmetric, independent of and trace-free. Its first two equilibrium equations are automatic; its third gives
away from the origin. Antiplane shear has zero trace, so isotropic Hooke's law reduces to . Hence
Locally this integrates to , represented on a suitable branch by . The strain condition is satisfied at every point of the punctured plane, but the displacement cannot be made globally single-valued there:
A gradient of a globally single-valued smooth displacement would instead integrate to zero around any closed curve. Local compatibility is therefore not sufficient on this multiply connected region.
A physical construction is a Volterra screw dislocation: cut the cylinder along a radial half-plane ending on its axis, shift one cut face relative to the other parallel to the axis, and rejoin. The axial mismatch is the Burgers vector. In the given normalization its magnitude is ; with a dimensional mismatch one uses . An intact pristine solid cannot reach this state by a smooth single-valued elastic deformation alone. The axis is a dislocation core where the continuum elastic field is singular and must be regularized by microscopic structure or plastic deformation. On the punctured domain the differential condition holds locally; globally its nonzero circulation detects the defect. In a distributional description, that incompatibility is concentrated on the axis. This is local strain compatibility versus screw-dislocation circulation.
Take the trace of the constitutive relation at zero stress. It gives . With the observed stress-free volume strain this requires
This is the bulk modulus. A stable solid resists uniform compression, so ; equivalently the elastic energy of a nonzero pure dilation is positive. The thermal strain is isotropic, , because here is the volumetric, not linear, thermal expansion coefficient.
Let . Using , stress divergence is
Zero body force and equilibrium therefore give
For an applied body force per unit volume , equilibrium is , so its right-hand side becomes . Consequently
cancels the effective thermal forcing in the displacement equation. Per unit mass the force is . This sign follows from the divergence of the thermal stress , which is . Cancelling that divergence is distinct from removing the stress tensor itself: boundary tractions and thermal compatibility still matter.
For spatially uniform heating with the entire boundary fixed, is the unique equilibrium displacement in a stable elastic solid, and
The stress is compressive hydrostatic stress for a temperature rise. The fixed boundary supplies the tractions that prevent thermal expansion. If varies spatially and no compensating body force is imposed, fixing the boundary alone does not generally force the interior displacement to vanish: one must solve the displayed forced Navier-Cauchy equation with on the boundary, then recover the stress. The simple uniform hydrostatic expression should not be asserted for arbitrary temperature fields. This is uniform thermal stress in a fully constrained solid.