Current density Created 2026-09-24 Updated 2026-10-14
The current density describes the amount and direction of local electric charge transport per area per time. Its SI unit is . Through a small area element with unit normal , the contribution to electric current is : the dot product selects transport through the surface. A current density tangent to the surface contributes zero. If current density is uniform and perpendicular to a wire's transverse slice, its magnitude satisfies
Here is the wire cross-sectional area. For nonuniform current density, is only the average normal component, and the surface integral is needed. [ref].
Consider two separate uniform-flow cases, each carrying electric current . A wire cross-sectional area of gives ; doubling the wire cross-sectional area to gives . Equal electric current can therefore mean different local transport intensity. This distinction matters for Joule heating, whose local power per volume depends on current density and electric field.
Figure 1.
Equal electric current through different wire cross-sectional areas gives different current densities
. Both cases carry with uniform normal current density. The transverse slices use the same spatial scale; the bars compare . Source. Details.
For a toy Electron transport model, stipulate mobile electron number density and drift velocity , with the positive unit normal . Each Electron has electric charge , where the elementary charge is exact in SI. These are defined model inputs, rather than measured parameters of a particular material. [ref] The current density and its magnitude are
For wire cross-sectional area and constant transport over time , this gives
The two minus signs make conventional current point opposite to the Electron drift velocity. A small drift velocity can carry an appreciable electric current because many charge carriers contribute; it does not specify the propagation speed of an electrical disturbance.
Electrical conductivity 2026-10-06
Electrical electrical conductivity relates current density to the local electric field in the rest frame of an isotropic ohmic medium: . It is a bulk material coefficient, distinct from a sheet surface electrical conductivity. A moving conductor instead uses the moving-conductor Ohm law.
Electrical resistance Created 2026-09-24 Updated 2026-10-14
Electrical resistance measures the electric potential difference needed to drive a given electric current through a component. For an Ohmic conductor under fixed material conditions, is constant and Ohm's law gives . The SI unit is the ohm, . At a fixed positive electric potential difference, increasing electrical resistance reduces electric current. Electrical conductance expresses the same response reciprocally. [ref].
For a straight uniform wire at rest, with constant electrical conductivity , length and wire cross-sectional area , the uniform Ohmic conductor model gives
The electrical resistivity characterizes the material; electrical resistance also includes geometry. Doubling length doubles , while doubling wire cross-sectional area halves , with material and temperature fixed. The uniform-field assumption includes insulated sides and equipotential end faces, as explained in uniform current in a straight homogeneous wire. [ref].
As a defined wire example, take , and . Then ; applying electric potential difference drives electric current . With the same length and material, a second wire of wire cross-sectional area has and carries at that same electric potential difference. Fixing electric potential difference here differs from fixing electric current in the current density comparison: stating what is held fixed is essential.
Ohm's law Created 2026-09-24 Updated 2026-09-24
Ohm's law states that the potential difference across an ohmic component equals its current times its resistance: .
PHYWE's documented experiment uses a one-metre slide wire, a connection box, an unknown resistor, a known comparison resistor, a supply, and a digital multimeter in steady-current mA mode as the null detector. Its two yellow detector leads join the fixed-resistor junction and the slider. Move the slider until the indicated electric current vanishes; read the two wire lengths on the ruler and infer the unknown electrical resistance from their ratio. The guide advises changing the comparison resistor if no null is reachable or the slider lies near an end.[ref]
The inference requires uniform electrical resistivity and wire cross-sectional area, so the two wire electrical resistances have the ratio of their lengths, by . Retaining PHYWE's labeling, its equation (6) is , where is the comparison electrical resistance. This is a different arm placement from our schematic. The guide's example table reports larger discrepancies near wire ends.[ref]
Useful additional controls distinguish a true null measurement from an insensitive or disconnected detector. Check the detector zero with the supply off, then move the adjustable arm slightly to either side of the candidate balance and verify opposite detector signs. Reconnect the unknown with short, secure leads and repeat the balance. Any lead or contact electrical resistance included in that arm contributes to the inferred value, even though a detector lead carries no electric current at exact balance. For very small unknown electrical resistances, four-terminal sensing addresses this separate connection problem; a detector null alone does not remove it.
Check for Joule heating by repeating at lower supply electric potential difference and with shorter powered intervals, holding ambient temperature fixed. At balance the unknown still dissipates power
Halving quarters this power while halving ideal detector sensitivity. A balance that moves with excitation or elapsed time suggests changing electrical resistance, including self-heating; it is not explained by passive detector loading alone. These are proposed controls, not claimed outcomes of PHYWE's experiment. Standard-resistor accuracy, wire uniformity, contact reproducibility and finite detector resolution still limit the electrical measurement. Large electrical resistances also make unwanted leakage paths consequential.
Wire cross-sectional area 2026-10-14
The wire cross-sectional area is the area of a slice perpendicular to the wire's axis. For a round wire of radius , it is . It enters both the uniform-flow formula for current density and the formula for the electrical resistance of a uniform Ohmic conductor.