Compression ratio of a perpendicular magnetohydrodynamic shock Created 2026-10-14 Updated 2026-11-05
Put and . The mass, momentum and energy jump conditions for a perpendicular magnetohydrodynamic shock factor into the unchanged state and
For the compressive physical branch , positive downstream pressure implies when and the upstream sound speed or Alfvén speed is nonzero. Indeed the polynomial implies
It then gives : the upstream flow exceeds the perpendicular fast magnetosonic wave speed. The exactly cold unmagnetized strong-shock limit reaches the upper compression bound.
Isothermal coplanar magnetohydrodynamic characteristic matrix Created 2026-10-14 Updated 2026-11-05
For one-dimensional flow obeying an isothermal equation of state with , the primitive variables form a four-variable hyperbolic system and is constant. The speeds relative to satisfy . These are the fast and slow magnetosonic waves. The independent out-of-plane Alfvén wave polarization and a freely advected entropy mode are absent from this reduced isothermal system.
Linearized ideal magnetohydrodynamic equations Created 2026-09-25 Updated 2026-11-05
The linearized ideal magnetohydrodynamic equations retain terms first order in perturbations about a chosen ideal-MHD background. Around a uniform state they describe Alfvén waves and magnetosonic waves.
Stig Lundquist, the author printed as S. Lundquist, reported an early laboratory test in 1949. The apparatus used mercury in a stainless-steel cylinder, a vibrating disk, and a floating mirror to indicate the motion at the liquid surface. The reproduced apparatus drawing also shows a scale; the accompanying account gives an applied magnetic field of .[ref]
The imposed magnetic field ran along the cylinder, while the bottom disk oscillated to excite azimuthal motion. Varying the drive frequency sought a standing wave resonance. A later authored experimental account describes this as an early hint: the resonance peak was not reached, and magnetic damping was substantial.[ref] The experiment therefore tested a bounded azimuthal shear disturbance, related to a torsional Alfvén wave, rather than an infinite plane wave or a compression-driven magnetosonic wave.
Figure 1.
Functional chain of Lundquist's early mercury Alfvén-wave test
. An original functional schematic of the mercury vessel, axial magnetic field, bottom disk excitation and surface mirror readout. It is not a dimensional reconstruction. The frequency scan sought a standing wave resonance; the early experiment did not establish a resolved peak. Details.
The magnetic field provides the controlled physical parameter: the ideal Alfvén wave prediction makes a propagation speed proportional to its strength, while a resonance also depends on the vessel's boundary conditions. A quantitative test must compare the driven response with finite-electrical conductivity theory and account for mechanical coupling and wall losses. An observed surface motion alone cannot distinguish all these mechanisms. The reproduced apparatus account gives neither a numerical drive frequency nor a field-off comparison. Lundquist's paper itself calls the experiment preliminary and proposes further investigations.[ref]
Magnetohydrodynamic turbulence is irregular nonlinear motion of an electrically conducting fluid coupled to a magnetic field. Alfvén waves and magnetosonic waves give propagation times in addition to the nonlinear mixing time. A strong guide field distinguishes directions parallel and perpendicular to it, so the resulting cascades need not be isotropic.
A polarization specifies the direction or trajectory of the oscillating velocity and magnetic field in a magnetohydrodynamic wave. The linear Alfvén wave has velocity perpendicular to the plane of the background magnetic field and wavevector; the magnetosonic waves have velocity in that plane. A real fixed polarization vector gives a linear oscillation. Two orthogonal components of equal amplitude in quadrature give a circular trajectory. For propagation parallel to a uniform field, combining the two degenerate transverse linear polarizations produces circular polarization; at finite amplitude its constant transverse magnetic-field magnitude removes the longitudinal magnetic pressure gradient.
Magnetosonic wave Created 2026-09-24 Updated 2026-11-05
A magnetosonic wave is a compressive MHD mode polarized in the plane of the wavevector and background magnetic field.
An Alfvén wave is a transverse disturbance restored by magnetic tension. In a uniform conducting fluid with background , a small transverse displacement bends the magnetic field lines. Magnetic flux freezing gives , and the linear transverse Lorentz force density is . Thus the Linear Alfvén wave equations reduce to
For this shear polarization, at linear order. The disturbance transports energy along the background magnetic field; a single traveling wave has equal perturbation magnetic energy and kinetic energy, with for propagation along . These properties distinguish it from compressive magnetosonic waves.
Figure 1.
Transverse displacement of field lines in a traveling Alfvén wave
. Details.
The ideal magnetohydrodynamics approximation requires strong electrical coupling and wavelengths large compared with microscopic scales. Finite electrical resistivity and viscosity dissipate the wave's energy. In stellar winds and other astrophysical plasmas, Alfvén waves carry disturbances and can contribute to heating when dissipated. The Lundquist liquid-metal Alfvén wave experiment provides a laboratory counterpart: a conducting liquid in a strong applied magnetic field transmits a transverse magnetic disturbance, making the field's mechanical restoring action measurable.
A plasma contains mobile charged species whose collective electromagnetic response matters. On scales large compared with the Debye length, positive and negative charge densities nearly cancel: this is quasineutrality, not the absence of electric currents or electric fields. For electrons of temperature and number density , the characteristic plasma screening and oscillation scales are
A collective plasma description requires many particles within a screening volume; long-wavelength, sufficiently slow behavior can often be described by magnetohydrodynamics with an appropriate fluid closure.
An individual particle feels the Lorentz force . In a uniform magnetic field, its transverse motion gyrates while its parallel motion remains free, giving a helical path when both components are present. The nonrelativistic cyclotron frequency and gyroradius are
When the system scale is much larger than and the relevant time scale longer than , the field strongly organizes transport across it, provided collisions do not interrupt the gyromotion. A perpendicular electric field also gives the common guiding-centre drift .
For a conducting fluid, the macroscopic Lorentz force density has the useful decomposition
These terms are magnetic pressure and magnetic tension. Magnetic tension resists bending, while magnetic-pressure gradients resist nonuniform compression. The plasma beta compares thermal and magnetic stresses.
With uniform magnetic diffusivity , the resistive induction equation is
If the magnetic Reynolds number , ideal magnetohydrodynamics applies approximately and magnetic flux freezing links the field geometry to fluid motion. Finite diffusivity permits field slippage and magnetic reconnection. Field tension supports Alfvén waves with ; coupled magnetic and gas compression also supports magnetosonic waves. These effects allow a field to transmit forces and angular momentum between distant parts of an astrophysical plasma.
Use the adiabatic form of ideal magnetohydrodynamics: heat conduction and external heating are absent, so . Infinite electrical conductivity and zero viscosity alone would not remove the thermal source terms on the cover page. If those terms are retained, the energy equation below must acquire on its right-hand side.
Expanding the continuity equation gives its conservative form . Using it to expand the conservative momentum derivative gives
For , the Lorentz force density is the divergence of the magnetic Maxwell stress tensor:
Combining these identities with momentum balance proves
The dyadic stress contains both magnetic tension and magnetic pressure; the sign in the flux is fixed by moving the magnetic force to the left.
For the energy equation, first dot momentum balance with and add the adiabatic internal-energy equation. The continuity equation converts their material derivatives into conservative derivatives, while . The result is
The ideal magnetohydrodynamic induction equation gives the magnetic counterpart. In fact,
Thus the outward Poynting vector is , and magnetic work cancels the fluid work. Finally, the continuity equation implies
Adding all three identities gives ideal magnetohydrodynamic energy conservation in the required local form:
where
The magnetic energy coefficient is , as in the original PDF. For a self-consistent, time-dependent gravitational field this local balance should not be confused with a global self-gravitating energy integral: the latter uses gravitational field energy, or the familiar one-half factor in after the field is eliminated.
Work in the shock frame of a thin planar discontinuity, with normal speed . A smooth gravitational potential has no finite jump through a vanishingly thin front; its advected contribution cancels using the common mass flux. Integrating the conservation laws gives constant normal mass, momentum and energy fluxes, together with the normal-field and tangential-electric-field conditions of the ideal magnetohydrodynamic shock conditions.
For a parallel magnetohydrodynamic shock, and . The magnetic solenoidal constraint makes the same on both sides. The normal momentum flux is ; its magnetic term is therefore identical upstream and downstream. The Poynting vector is zero because . Hence the nontrivial jumps are exactly the Rankine-Hugoniot conditions for a perfect gas:
with specific enthalpy . Physically, motion along the straight field neither bends it nor compresses its transverse flux. The field consequently provides no changed stress or energy flux in this purely parallel geometry. This conclusion does not apply to a shock that develops a transverse magnetic field.
For a perpendicular magnetohydrodynamic shock, the magnetic field is tangential and the velocity normal. Steady induction makes continuous, while the continuity equation makes continuous. Dividing gives the magnetic flux freezing relation
Put , so and . Constant normal momentum flux now reads . Substitution gives
The magnetic correction is negative for compression: part of the incoming ram pressure builds magnetic pressure instead of thermal pressure.
Here the Poynting vector has normal component . Divide the constant energy flux by the nonzero mass flux to obtain
With , this gives the second expression for downstream pressure:
In this expression is the only downstream unknown. Equating the two pressure expressions and multiplying by yields
up to an overall minus sign, where and
The discarded factor is the unchanged state, not a compressive shock. This derives the polynomial for the compression ratio of a perpendicular magnetohydrodynamic shock without omitting its trivial branch.
For the usual physical adiabatic index , is strictly increasing for positive , has , and has one positive root. Since
that root is greater than one precisely when . The necessity is not limited to : for any , eliminating using gives
For , positive downstream pressure requires when . Moreover,
The bracket is positive throughout , even when . The exactly cold unmagnetized limit gives the familiar strong-shock upper compression ratio directly. Thus the physical compressive branch requires
The PDF's final denotes this same incoming speed . The right side is the squared speed of a perpendicular fast magnetosonic wave: the upstream flow must be super-fast-magnetosonic so that this compressive signal cannot run upstream against the incoming flow. At equality the shock amplitude vanishes into a characteristic disturbance.