David H. Kohn 2026-11-05
David H. Kohn is a biomedical engineer whose research connects biomineralization, biomaterials and biomechanics. His University of Michigan profile describes two related questions: how the organization of mineralized tissue produces its mechanical behavior, and how understanding natural material formation can inform engineered biomaterials. This is an example of biomimetics: learning design principles from biological structures rather than merely copying their chemical ingredients.[ref]
Figure 1.
David H. Kohn, from his University of Michigan faculty profile
.
His joint work with M. D. Morris, W. F. Finney and Rupak M. Rajachar used Raman spectroscopy to investigate bone during elastic deformation. Their custom mechanical tester fitted the stage of a Raman microprobe and accepted hydrated specimens. The experiment paired loading of murine femora in tension with measurements of mineral phosphate-band shifts, while keeping loading below yield.[ref] The combination asks how a local molecular response accompanies the deformation of an entire composite material.
An original idealized calculation explains why the two measurements are complementary. For a harmonic oscillator with effective bond force constant and reduced mass , the vibrational wavenumber is
where is the speed of light. Holding fixed gives the first-order relation . A hypothetical band moving from to would correspond to approximately a decrease in this model's effective bond force constant. This Raman shift as a probe of bond stiffness is a local vibration model; the chosen numbers are not measurements from Kohn's paper.
A specimen's Young's modulus instead relates its macroscopic stress to its strain in a specified loading direction and regime. It cannot be read directly from one vibrational wavenumber. Composite material geometry, phase interactions and orientation mediate the connection between a local bond force constant and a bulk elastic modulus. Even a large local spectral response need not imply an equally large change in bulk stiffness.
This distinction gives the experiment its interest: a tensile testing apparatus and a spectroscopic probe observe different levels of the same loaded material. Their agreement or disagreement can discriminate structural explanations that a single bulk measurement would leave unresolved. Repeating both measurements during unloading would additionally test whether the changes reverse. Kohn's institutional description places this multiscale mechanics question alongside the development of new biomaterials.[ref]
Kelvin-Voigt rod Green function Created 2026-10-18 Updated 2026-11-05
For a rod with unit mass density and elastic modulus, the Kelvin-Voigt model gives , . For the operator with the opposite overall sign, , the inverse under the Fourier transform convention is the displayed expression. Its poles are . With real, the retarded fundamental solution in spatial Fourier variables is . Its initial derivative is , fixed by the leading coefficient . At a repeated root take the continuous limit; for imaginary the sine becomes a hyperbolic sine.
Palpation 2026-11-05
Palpation is examination by touch with the hands or fingers. It uses physical contact to assess features such as an organ's apparent size, position, consistency and tenderness. The observed feature and the resulting clinical diagnosis are separate: feeling a moving or resistant region does not by itself identify the complete underlying anatomy or disease.[ref]
The force applied during palpation is part of the measurement. In an original simplified indentation example, suppose a probe produces of displacement under a load. The secant stiffness for that observation is
A second specimen requiring at the same displacement has twice this apparent stiffness. That ratio is not automatically a ratio of intrinsic elastic modulus values: contact geometry, specimen thickness, support and deformation rate can alter the force-displacement curve. Touch supplies a mechanical observation whose interpretation requires an appropriate model.
A clinical measurement study makes the distinction concrete. S. D. Eilen and colleagues compared precordial palpation with two-dimensional echocardiography in 41 patients. They compared the location and palpable diameter of the apical impulse with left ventricle end-diastolic volume. A lateral impulse location was sensitive but not specific for enlargement. Within the reported subgroup without ventricular hypertrophy, an impulse diameter above in the left-lateral position had reported diagnostic sensitivity and diagnostic specificity . Those are results for that study's condition and subgroup, rather than universal performance figures for touch.[ref]
A small probability example explains why both attributes matter. In a stipulated set with 20 enlarged and 80 non-enlarged hearts, a rule detecting 18 enlarged hearts but also flagging 24 non-enlarged hearts has diagnostic sensitivity and diagnostic specificity . Only of its positive results identify enlargement. These invented counts are not a reconstruction of the 41-patient study. They show why a palpable feature must be tested against an independent reference and interpreted with the population being examined.
Repeating a specified observation can assess reproducibility, while comparison with echocardiography assesses a different question: correspondence with the chosen anatomical reference. Holding body position and observation method consistent helps distinguish those sources of variation. A reliable description of what was felt is necessary evidence, but reproducibility alone does not establish the causal explanation.
Inelastic neutron scattering measures both momentum and energy exchanged with the crystal. Comparing incident and outgoing neutron wavevectors gives , while their energy difference gives a created or annihilated phonon energy . Crystal momentum conservation identifies the reduced phonon wavevector modulo a reciprocal-lattice vector. Varying scattering geometry maps dispersion curves and polarization-dependent intensities across a substantial part of the Brillouin zone.
Inelastic X-ray scattering provides a complementary energy- and momentum-resolved probe, particularly when small samples or high-pressure environments favor photon beams. Raman and infrared spectroscopy measure optical-frequency resonances subject to different symmetry selection rules. Photon momentum at these frequencies is usually small on the Brillouin-zone scale, so these methods mostly sample near the zone center rather than an arbitrary phonon wavevector. Brillouin scattering and ultrasonic measurements probe low-frequency acoustic motion and infer sound velocities or elastic constants.
Heat-capacity measurements constrain the thermally weighted vibrational density of states and its low-frequency behavior, but do not by themselves reconstruct a unique wavevector-resolved dispersion. Elastic diffraction and temperature-dependent displacement factors also constrain mean-square motion, while energy-resolved inelastic measurements distinguish individual excitations directly. A monatomic scalar chain has only the acoustic branch derived below; it should not be assigned an optical branch merely because Raman spectroscopy exists for more complicated crystals.
Differentiating the displacement gives
The isotropic stress is diagonal, with
The two transverse traction-free conditions set the latter entries to zero. Hence and
Substitution shows ; solving for the two Lamé parameters gives
To determine the allowed interval without assuming signs not given, put . Then , so
Therefore . The endpoints would require a degenerate elastic modulus, so they are excluded by the strict material inequalities.
quantitative nanomechanical mapping can image the flake without an electrical return path. Repeated AFM force curves provide surface topography, adhesion and deformation or effective elastic modulus channels. The step and differences in tip–surface interaction can distinguish graphene from glass. For an atomically thin supported sheet the contact response is strongly substrate dependent, so fitting a three-dimensional half-space contact model does not directly measure the intrinsic in-plane Young's modulus of free graphene. Calibrate the cantilever spring constant, deflection sensitivity and tip radius, use small loads, and compare bare substrate. The manufacturer's description specifies the force-curve origin of the mechanical channels.[ref]
Three suitable approaches give complementary contrast. tapping-mode atomic force microscopy supplies surface topography and an oscillation-phase image. It reduces lateral drag and is often effective for soft block copolymer domains. Its phase contrast depends on elastic response, adhesion, dissipation and operating setpoint together: a bright phase domain is not automatically the stiffer polymer. Check contrast as amplitude and setpoint change and use a known reference.
quantitative nanomechanical mapping fits the repulsive portions of many AFM force curves and separately maps effective elastic modulus, adhesion and deformation. It directly addresses the stiffness difference and limits maximum force. Its quantitative result depends on tip radius, force calibration, contact model, loading rate and film thickness; domains narrower than the contact footprint are mixed and the substrate can dominate a thin film. Use small indentation, substrate controls and a suitable viscoelastic interpretation.
friction force microscopy can reveal domains with different frictional and adhesive response, using torsional deflection during contact scans. It is simple and sensitive to surface chemistry, but continuous shear may deform or displace soft domains, and slope/topography can contaminate the lateral signal. Acquire trace–retrace pairs at several low normal loads and check reproducibility. Use a mechanical-modulus map to test the stiffness assignment; phase or friction contrast alone does not uniquely identify stiffness or chemical composition.
Two useful properties are adhesion and contact elastic modulus. The pull-off force, the most negative force on retraction relative to the noncontact baseline, maps adhesion. Fit the contact part of the force-indentation relation using a suitable contact mechanics model to obtain a reduced elastic modulus; for example, the DMT contact model uses
where , is the calibrated tip radius and is indentation. Converting to a sample Young's modulus also requires the tip modulus and the two Poisson's ratios. The approach curve alone does not supply a retraction pull-off measurement. The loop area can additionally map dissipated energy; it is not automatically a purely viscous loss.[ref]
For an approximately isotropic rock, the P wave and S wave speeds are
where is bulk modulus, is shear modulus, and is density. Five important controls are:
The measured core seismic velocities should therefore be checked against in-situ saturation, effective stress, and temperature; laboratory values need not transfer unchanged offshore.
Mapping of local mechanical response from calibrated AFM force curves. Deformation, adhesion and a model-dependent contact elastic modulus can be separated more directly than by interpreting oscillation phase alone. Tip radius, indentation depth, loading rate and substrate response constrain quantitative interpretation.
Retardation time (viscoelasticity) Created 2026-10-20 Updated 2026-11-05
The characteristic time for a delayed strain response to approach equilibrium under a step in stress. For a Kelvin-Voigt model with elastic modulus and viscosity , the equation gives , where . A relaxation time instead describes decay of stress after an imposed strain; the two times need not coincide in a standard linear solid model.
Stress-strain curve 2026-11-05
A stress-strain curve plots a material's stress response against a specified strain measure during a loading experiment. Its initial slope gives an elastic modulus in a linear regime; yielding, hardening and fracture can produce later changes.
The curve depends on temperature, loading rate, sample history and the definitions of stress and strain. Engineering stress divides force by original cross-sectional area, whereas true stress uses current area. After necking these can differ greatly. Unloading can distinguish recoverable elastic strain from permanent deformation, so one loading curve alone does not specify every constitutive property.
Yield stress Created 2026-10-20 Updated 2026-11-05
The yield stress is the stress threshold beyond which a material sustains irreversible flow under the specified loading conditions. Time-dependent materials require an operational measurement protocol; a single elastic modulus does not determine their yield stress.