An electrostatic accelerator gives a charged particle kinetic energy by taking it through a sustained electric potential difference. Its ion source, accelerating tube and target form a particularly direct chain: prepare a charge, let an electric field do work, and measure what arrives or what the target emits. A vacuum reduces collisions with gas before the beam reaches its target. The Cockcroft-Walton generator supplies the potential by accumulating electric charge on capacitors.
For a fixed electric charge , a time-independent electric potential and negligible collisions or radiation losses, conservation of energy gives
Here is the signed potential drop along the trajectory. A proton starting nearly at rest at and arriving at ground gains : a chosen gives , by the definition of the electronvolt. Several intermediate electrodes can distribute that drop along a tube, but the gains telescope to the same endpoint difference. Passing through more electrodes does not multiply the available kinetic energy beyond .
This is the distinction from a cyclotron. In a static electric field, a closed trip gives zero net work. A cyclotron changes the gap electric field between successive visits, so correctly timed particles repeatedly gain kinetic energy. Its limit involves the cyclotron resonance condition and relativistic detuning of a cyclotron; a single-pass electrostatic accelerator instead requires the full accelerating electric potential difference to be sustained at once. Neither machine's beam energy by itself specifies the energy released by a nuclear reaction.
A voltage multiplier made of rectifiers and capacitors that transfers electric charge from an alternating supply into a series stack of stored electric potential differences. The rectifiers allow charge transfer during selected portions of the cycle; the capacitors retain charge between transfers. The supply continually replaces charge removed by the load. Multiplication of voltage does not multiply energy: the input must supply the output power and losses.
In his 1951 lecture The Artificial Production of Fast Particles, Ernest Thomas Sinton Walton describes the fourfold multiplier's series storage capacitors and alternating transfer capacitor in Fig. 2, p. 190. This is a mechanism for producing a nearly steady accelerating potential from an alternating input.[ref]
Figure 1.
Voltage accumulation and particle acceleration are different steps
. Original functional diagram. Three ideal storage stages illustrate a chosen multiplier model; charge transfer is shown as a functional block rather than a wiring diagram. The beam crosses one total potential drop. The lower chain summarizes the lithium experiment's target and scintillation readout, not the geometry or stage count of the 1932 apparatus. Details.
Define a stage as one storage increment of , with the alternating input's peak electric potential difference relative to its reference, not its peak-to-peak value. Assume ideal rectifiers, no load, no leakage or stray capacitance, a stiff alternating source and enough cycles to reach equilibrium. For such stages,
The factor two follows from adding the input's next opposite excursion to an already stored peak. The subsequent series increments add. This ideal argument concerns equilibrium voltage; it supplies neither the charge-up time nor the useful load electric current.
To isolate the effect of drawing charge, consider the following original reservoir model. Each storage stage has equal capacitance ; a constant output electric current removes between replenishment events of frequency . Every series reservoir loses this charge, hence its voltage falls by per interval. Suppose replenishment removes a fixed fraction of each reservoir's accumulated deficit, with . This is an explicit phenomenological pump rule, not a solution of a particular multiplier's rectifier network. If is the deficit immediately after event , then
Here and are the equilibrium deficits just after and just before replenishment. Linear discharge between events gives the average output and peak-to-peak variation
For chosen dimensionless settings , and , the output varies between and , averaging , instead of the unloaded . Starting with zero deficit, the recurrence approaches equilibrium geometrically with factor . Taking recovers the ideal ladder; increasing or reduces droop in this model. As , effective replenishment fails and the small-deficit assumption fails too.
Real multiplier stages have unequal charge-transfer burdens; their mean deficits need not be equal and depend on topology, input impedance and parasitic capacitance. Thus this reservoir model explains droop and voltage variation without claiming their exact dependence on stage count for a real Cockcroft-Walton generator. In particular, adding more stages cannot be judged solely by the unloaded . For a beam sampling a slowly varying output, the electrostatic acceleration energy gain follows that instantaneous potential drop, so voltage variation also produces a spread of beam kinetic energies.
In 1932 John Douglas Cockcroft and Ernest Thomas Sinton Walton accelerated hydrogen ions from a discharge source through an evacuated tube onto lithium at . A side-facing zinc sulfide screen, viewed by microscope, showed particle scintillations. Mica stopped scattered protons; switching off or blocking the beam removed the flashes. An external screen allowed absorption-range measurements.[ref]
Magnetic deflection checked voltage calibration. Opposite screens and independent observers found excess coincidences for a thin lithium target, supporting paired alpha particle emission; geometry and screen efficiency limited detection.[ref]
John Douglas Cockcroft's 1951 lecture recalls detection at and an absorption range about , then refined alpha particle energies about each. He places the work under Ernest Rutherford's direction. The inferred nuclear reaction was lithium-7 plus a proton producing two alpha particles.[ref]
The logic has several independent links. Beam blocking tests whether the flashes depend on bombardment. An absorber tests whether scattered beam particles could reach the screen. A particle range tests product identity and kinetic energy, while coincidences test whether two products belong to one event. These tests support a reaction interpretation jointly; counting flashes alone is not an isotope identification, and a range-to-energy conversion needs calibration. The lithium proton reaction energy below is a modern calculation, separate from those historical measurements.
The nuclear reaction
conserves electric charge and total nucleon count: and . Its nuclear reaction Q-value is the initial minus final rest energy. It is additional to the incoming beam kinetic energy; the accelerator triggers a rearrangement whose products can carry much more kinetic energy than the incident proton.
Use one consistent set of neutral-atom isotope masses, in unified atomic mass units, from the National Institute of Standards and Technology:
These are isotope masses, not element-averaged atomic weights.[ref] With ,[ref]
The four electron rest masses cancel between sides. Differences of total electronic binding energies do not cancel exactly: this atomic-mass result approximates the bare-nucleus nuclear reaction Q-value at the displayed scale, not at arbitrary precision. No mixture of rounded nuclear binding energies is needed. At chosen incident kinetic energy on a stationary target, the two outgoing alpha particles together carry approximately before losses in the target and detector window.
Figure 1.
Reaction energy and the laboratory recoil of two alpha particles
. Original calculation using the stated neutral-atom isotope masses, electron-mass subtraction and neglected electronic binding corrections. Chosen incident proton energy 0.500 MeV and stationary lithium-7 target; no target or detector losses. Left: energy released by the mass difference plus incident kinetic energy. Right: exact two-body relativistic transformation within these mass assumptions; equal and opposite center-of-mass momenta need not give equal laboratory kinetic energies. Curves parameterize paired events and are not an angular probability distribution or historical data. Details.
Equal product masses imply equal kinetic energies and opposite momenta in the center of mass frame. The laboratory frame has nonzero initial momentum because the proton is moving. Conservation of momentum therefore forbids the two laboratory momenta from always being equal and opposite. The products are equal in laboratory kinetic energy only for particular emission directions, not for every event.
An exact two-body calculation makes this distinction quantitative. Write , , , and for incident kinetic energy. Express every quantity below in the same energy units; is momentum times the speed of light. For a stationary target,
Here is the center-of-mass energy, and is the center-of-mass speed divided by the speed of light. Each outgoing alpha particle has center-of-mass total energy and momentum-times- magnitude . A Lorentz transformation gives the paired laboratory kinetic energies, with measured from the incident beam in the center of mass frame:
Their sum is independent of and equals . Their difference is ; the symmetry belongs to the product interchange and the center of mass frame.
For the chosen model, subtract electron rest masses from each neutral-atom mass, neglect electronic binding energies, and use .[ref] At , the paired laboratory kinetic energies are approximately and ; at both are approximately . In the latter case both products have a forward laboratory momentum component, so even equal laboratory kinetic energies do not imply back-to-back laboratory trajectories. A real thick target and finite detector acceptance would broaden or select these ideal kinematic possibilities.

Articles by others on the same topic (0)

There are currently no matching articles.