Consider two identical, lossless parallel mirrors with intensity reflectivity , separation , and a uniform transparent medium of refractive index . Fix one polarization of an electromagnetic wave and an internal angle of incidence measured from the mirror normal vector. Illuminate with a monochromatic wave having planar wavefronts; the emerging contributions must overlap coherently in the detected direction. Define using the same incident and exit media. Each mirror transmits a fraction of incident power. Its reflected wave amplitude has magnitude , so two internal specular reflections multiply the circulating complex amplitude by magnitude , not .
Let be the vacuum wavelength and choose the reflection wave phase convention in which the product of the two internal amplitude reflection coefficients is real and positive. The phase difference between successive transmitted contributions, evaluated on a common outgoing wavefront, isWith other mirror coatings or phase conventions, use the total , where is the sum of the two internal reflection wave phases. The stated resonance positions presume modulo ; a constant nonzero shifts them, while a frequency-dependent one can also change their spacing.
Why does the cosine appear rather than its reciprocal? Inside the gap, the extra two legs have optical path length . But the later emerging contribution starts farther along the mirror. Comparing both on one outgoing wavefront subtracts from that path difference, leaving . Equivalently, a plane wave's mirror-normal wavevector component is , so the round-trip wave phase is . The diagram uses the same medium outside and inside to show the common-wavefront subtraction directly; at a refracting exit interface, tangential wavevector matching in Snell's law supplies the same result.
Absorb the common first-pass wave phase into the incident complex amplitude . Successive transmitted contributions are , , and so on. The superposition principle and the convergent geometric series giveThe last step expands the squared complex modulus as . This transmission profile is often called the Airy transmission function; it is distinct from the Airy disk, a diffraction image of a circular aperture. The University of Washington's lab handout gives the same transmission profile and distinguishes mirror reflectivity from other sources of peak broadening.[ref]
Fabry-Perot Interferometer, University of Washington Physics 331. Fabry-Perot Interferometer, theory equation (2), Finesse discussion, equations (4)–(8)
For an original example, set . At , the amplitudes add to , so . At , they alternate in sign and add to , so . At , the amplitude is and . Adding the individual intensities instead would give , independent of wave phase; that discards the wave interference responsible for the peaks.
In general the maximum is at , with integer , and the minimum is halfway between peaks. Perfect resonant transmission requires identical lossless mirrors, coherent illumination, and sufficient time to establish the steady field. Absorption, unequal mirror transmission, finite beams that fail to overlap, and fluctuations of can reduce it. The exactly reflecting case is excluded: no incident power enters through a perfectly reflecting mirror, and the resonant limit is singular.
Finesse 2026-10-14
The finesse of a Fabry–Pérot interferometer is its free spectral range divided by a transmission peak's full width at half maximum. Large finesse means a narrow accepted frequency interval compared with the spacing between repeated orders. Here half maximum means of the ideal unit peak, with zero detector background subtracted; it does not mean halfway between the transmission minimum and maximum.
Write for the coefficient multiplying in Fabry–Pérot transmission from multiple reflections. This coefficient is sometimes called the coefficient of finesse; it is not the finesse . About a resonance , put . Solving givesand, since one free spectral range advances the wave phase by ,These are exact for the ideal nondispersive model with constant and linear frequency dependence of . The inverse sine requires , or . At equality, neighbouring peaks merely touch half maximum at their shared minima: the nominal width is one full free spectral range and . Isolated half-maximum peaks require the strict inequality. Below this threshold the transmission never falls to , so this peak-width definition supplies no finesse; at the transmission is flat.
For large reflectivity, the small-angle approximation givesThis is a high-reflectivity approximation, not an identity for every . The original dimensionless examples below have exact full width at half maximum values obtained from the inverse sine formula.
Increasing mirror reflectivity narrows Fabry–Pérot interferometer transmission peaks
. Original stipulated dimensionless model for , with and modulo . All curves peak at unity and repeat after . The second panel enlarges the central resonance; coloured segments at mark each exact full width at half maximum. The inset compares exact finesse with the high-reflectivity approximation. These are calculations, not measured scans. Details.The beauty of the narrowing is visible directly in the geometric series: large preserves contributions from many round trips, so a small phase difference accumulates across many terms and spoils their addition. For the stipulated vacuum gap, gives an ideal full width at half maximum of about . This instrumental width is not a measured spectral line width. A real scan also depends on the source profile, accepted angles, mirror shape, alignment, and scan stability. The University of Washington handout separately discusses mirror-reflectivity, mirror-flatness, and detector-pinhole contributions; increasing alone cannot remove the others.[ref]
Fabry-Perot Interferometer, University of Washington Physics 331. Finesse discussion, equations (5)–(8), and §2.3 Determine the Finesse
Scanning Fabry–Pérot measurement 2026-10-14
An actual teaching experiment in LM-0300 Fabry Perot Spectrum Analyser by Walter Luhs, §§3.1.1–3.1.2, prepares a green laser beam by aligning it near and far along a rail, then centring back-reflected light from adjustable curved mirrors. An actuator using piezoelectricity moves one mirror. A screen first displays interference fringes; a focusing optical lens and photodiode then replace the viewing arrangement. The oscilloscope records the photodiode signal and the piezo drive reference on separate channels, using the latter as its trigger. Alignment and mirror separation are adjusted to suppress extra transverse normal modes; source temperature and drive electric current are controlled. Repeated peaks calibrate the scan using the appropriate free spectral range, and their spacing divided by their full width at half maximum estimates finesse.[ref]
This experiment uses a confocal curved-mirror cavity, whose repeated peak families can have spacing in air; it must not be calibrated blindly with the parallel-mirror . Extra transverse normal modes can mimic source features. A finite measured peak width bounds source sharpness only after instrumental broadening is considered; it does not determine the source's intrinsic width by itself.[ref]
LM-0300 Fabry Perot Spectrum Analyser by Walter Luhs. §3.1.2 p. 20: transverse modes, confocal calibration and source-linewidth inference
For an independent ideal scan calculation, hold a narrow laser wavelength fixed and vary the parallel-mirror gap at normal incidence. Advancing one resonance order requires . If changes uniformly over the measured interval, the time between repeated peaks divided by their full width at half maximum in time equals finesse. The cancellation of scan rate follows from : both peak spacing and peak width are divided by the same . It fails if the scan rate changes appreciably over that interval. A practical control in the University of Washington's motor-driven flat-mirror experiment is to check that successive peaks are equally spaced before using the time axis this way; its handout also warns that table strain and aggressive low-pass filtering alter the trace.[ref]