Fabry–Pérot transmission from multiple reflections Created 2026-10-14 Updated 2026-10-20
Consider two identical, lossless parallel mirrors with intensity reflectivity , separation , and a uniform transparent medium of refractive index . Fix one polarization of an electromagnetic wave and an internal angle of incidence measured from the mirror normal vector. Illuminate with a monochromatic wave having planar wavefronts; the emerging contributions must overlap coherently in the detected direction. Define using the same incident and exit media. Each mirror transmits a fraction of incident power. Its reflected wave amplitude has magnitude , so two internal specular reflections multiply the circulating complex amplitude by magnitude , not .
Let be the vacuum wavelength and choose the reflection wave phase convention in which the product of the two internal amplitude reflection coefficients is real and positive. The phase difference between successive transmitted contributions, evaluated on a common outgoing wavefront, is
With other mirror coatings or phase conventions, use the total , where is the sum of the two internal reflection wave phases. The stated resonance positions presume modulo ; a constant nonzero shifts them, while a frequency-dependent one can also change their spacing.
Why does the cosine appear rather than its reciprocal? Inside the gap, the extra two legs have optical path length . But the later emerging contribution starts farther along the mirror. Comparing both on one outgoing wavefront subtracts from that path difference, leaving . Equivalently, a plane wave's mirror-normal wavevector component is , so the round-trip wave phase is . The diagram uses the same medium outside and inside to show the common-wavefront subtraction directly; at a refracting exit interface, tangential wavevector matching in Snell's law supplies the same result.
Figure 1.
Multiple specular reflections become a coherent sum of transmitted complex amplitudes
. Original ideal geometry and amplitude construction, not apparatus data. The oblique rays expose successive round trips and the common outgoing wavefront; is internal. The amplitude panels independently use at and . Only the first five terms are drawn, with the infinite-sum endpoints marked. At normal incidence the outgoing contributions overlap directly. Details.
Absorb the common first-pass wave phase into the incident complex amplitude . Successive transmitted contributions are , , and so on. The superposition principle and the convergent geometric series give
The last step expands the squared complex modulus as . This transmission profile is often called the Airy transmission function; it is distinct from the Airy disk, a diffraction image of a circular aperture. The University of Washington's lab handout gives the same transmission profile and distinguishes mirror reflectivity from other sources of peak broadening.[ref]
For an original example, set . At , the amplitudes add to , so . At , they alternate in sign and add to , so . At , the amplitude is and . Adding the individual intensities instead would give , independent of wave phase; that discards the wave interference responsible for the peaks.
In general the maximum is at , with integer , and the minimum is halfway between peaks. Perfect resonant transmission requires identical lossless mirrors, coherent illumination, and sufficient time to establish the steady field. Absorption, unequal mirror transmission, finite beams that fail to overlap, and fluctuations of can reduce it. The exactly reflecting case is excluded: no incident power enters through a perfectly reflecting mirror, and the resonant limit is singular.
Finesse 2026-10-14
The finesse of a Fabry–Pérot interferometer is its free spectral range divided by a transmission peak's full width at half maximum. Large finesse means a narrow accepted frequency interval compared with the spacing between repeated orders. Here half maximum means of the ideal unit peak, with zero detector background subtracted; it does not mean halfway between the transmission minimum and maximum.
Write for the coefficient multiplying in Fabry–Pérot transmission from multiple reflections. This coefficient is sometimes called the coefficient of finesse; it is not the finesse . About a resonance , put . Solving gives
and, since one free spectral range advances the wave phase by ,
These are exact for the ideal nondispersive model with constant and linear frequency dependence of . The inverse sine requires , or . At equality, neighbouring peaks merely touch half maximum at their shared minima: the nominal width is one full free spectral range and . Isolated half-maximum peaks require the strict inequality. Below this threshold the transmission never falls to , so this peak-width definition supplies no finesse; at the transmission is flat.
For large reflectivity, the small-angle approximation gives
This is a high-reflectivity approximation, not an identity for every . The original dimensionless examples below have exact full width at half maximum values obtained from the inverse sine formula.
Mirror intensity reflectivity Exact Exact finesseApproximate finesse
Figure 1.
Increasing mirror reflectivity narrows Fabry–Pérot interferometer transmission peaks
. Original stipulated dimensionless model for , with and modulo . All curves peak at unity and repeat after . The second panel enlarges the central resonance; coloured segments at mark each exact full width at half maximum. The inset compares exact finesse with the high-reflectivity approximation. These are calculations, not measured scans. Details.
The beauty of the narrowing is visible directly in the geometric series: large preserves contributions from many round trips, so a small phase difference accumulates across many terms and spoils their addition. For the stipulated vacuum gap, gives an ideal full width at half maximum of about . This instrumental width is not a measured spectral line width. A real scan also depends on the source profile, accepted angles, mirror shape, alignment, and scan stability. The University of Washington handout separately discusses mirror-reflectivity, mirror-flatness, and detector-pinhole contributions; increasing alone cannot remove the others.[ref]
Let be the single-mirror power reflectivity and the propagation angle inside the gas. Define as the vacuum wavelength. Successive transmitted complex amplitudes differ by a round-trip factor , where, for real dielectric reflection coefficients whose product has positive sign,
The cosine arises by comparing successive emerging rays on the same outgoing wavefront; it is not the literal zigzag distance . Equivalently, the round-trip phase is . If the source's is the angle in external air, Snell's law gives and
If denotes the internal angle, simply set .
For identical lossless mirrors, their power transmission is . In an energy-normalized amplitude convention this is ; more general interface amplitudes require the corresponding wave impedance factors. The geometric series of transmitted amplitudes gives
Hence
This is Fabry–Pérot transmission from multiple reflections.[ref]
At normal incidence, for nondispersive and zero net reflection phase modulo , the resonance condition is . The resonance frequencies and free spectral range are
For finite the resonances have finite width, and transmission away from them is nonzero. Thus “only discrete frequencies” is an ideal high-reflectivity description of the selected resonances, not an exact statement about the support of the transmitted spectrum. For example, at still gives .
At half the unit peak, . Measuring the phase displacement from a resonance yields
The last expression is the high-reflectivity approximation, with finesse . At , the full phase width is about radians and . At , the minimum transmission is , so the trace never reaches half the peak and this full width at half maximum is not defined. The exact half-maximum condition requires .
Figure 1.
Fabry–Pérot transmission for mirror reflectivities 0.1 and 0.9
. Original ideal Fabry–Pérot interferometer calculation. The broad low-reflectivity curve stays above half maximum; the right panel resolves the high-reflectivity peak and its full width at half maximum. Details.
For the absorbing Fabry–Pérot mirror phase and transmission, write and let be the power transmission of one mirror. Optical absorption makes . The transmitted intensity becomes
Here the phase formula is at normal incidence. The peak is reduced below unity, while a change in changes the width. The complex reflection phase also moves the resonances: if is approximately constant,
If either or depends on frequency, this is an implicit condition and the free spectral range need not be constant. No numerical shift is determined without the mirrors' optical response.
Let the first transmitted complex amplitude be : two amplitude transmission factors each of magnitude give magnitude . Each extra internal round trip adds two amplitude reflections, with combined magnitude , and phase . With the mirror phase convention already incorporated in the stipulated ,
Taking the squared modulus gives
It is , not , that multiplies the field after a round trip; would be the corresponding round-trip intensity fraction.
At resonance , . If is the positive phase displacement to half maximum,
For , the stipulated high-reflectivity approximation gives , while the exact value is . The full width is twice this value. With , , and the pattern repeats every . Its ideal finesse is approximately .
A wavelength component resonates at . Within the scan interval, the individual resonances are
No neighboring orders of these lines fall within the stated interval. The observed signal is the sum of their two Airy transmissions, since different spectral components add intensities. Individual resonance positions identify the two peaks to the plotted precision; the tails cause very small shifts of the maxima of the sum.
The gap-coordinate full width is
The separation is , about full widths, so the two components can be resolved by the ideal etalon. The equivalent wavelength resolution near order is about , smaller than their separation.
The added wavelength has an order- resonance at
It lies between the preceding two peaks; its adjacent orders are outside the scan. Its input strength was not specified, so the third peak's height cannot be uniquely assigned. The original plot uses equal strength only as a declared illustration.
This is an order-identification problem: the free spectral range near is . A line more than one free spectral range away can appear among peaks of another order. A lower-resolution prefilter or additional dispersive spectrometer is needed to identify the order; a narrow peak alone does not identify an absolute wavelength. mirror parallelism, beam collimation and detector angular acceptance must also be controlled before attributing a measured width entirely to reflectivity.[ref]
An actual teaching experiment in LM-0300 Fabry Perot Spectrum Analyser by Walter Luhs, §§3.1.1–3.1.2, prepares a green laser beam by aligning it near and far along a rail, then centring back-reflected light from adjustable curved mirrors. An actuator using piezoelectricity moves one mirror. A screen first displays interference fringes; a focusing optical lens and photodiode then replace the viewing arrangement. The oscilloscope records the photodiode signal and the piezo drive reference on separate channels, using the latter as its trigger. Alignment and mirror separation are adjusted to suppress extra transverse normal modes; source temperature and drive electric current are controlled. Repeated peaks calibrate the scan using the appropriate free spectral range, and their spacing divided by their full width at half maximum estimates finesse.[ref]
This experiment uses a confocal curved-mirror cavity, whose repeated peak families can have spacing in air; it must not be calibrated blindly with the parallel-mirror . Extra transverse normal modes can mimic source features. A finite measured peak width bounds source sharpness only after instrumental broadening is considered; it does not determine the source's intrinsic width by itself.[ref]
For an independent ideal scan calculation, hold a narrow laser wavelength fixed and vary the parallel-mirror gap at normal incidence. Advancing one resonance order requires . If changes uniformly over the measured interval, the time between repeated peaks divided by their full width at half maximum in time equals finesse. The cancellation of scan rate follows from : both peak spacing and peak width are divided by the same . It fails if the scan rate changes appreciably over that interval. A practical control in the University of Washington's motor-driven flat-mirror experiment is to check that successive peaks are equally spaced before using the time axis this way; its handout also warns that table strain and aggressive low-pass filtering alter the trace.[ref]