Bessel lens displacement method 2026-10-05
Etendue bench measurement 2026-10-14
A proposed optical bench test uses a steady illuminated diffuse patch, a relay made from two optical lens elements, interchangeable centred circular stops, and a calibrated optical power meter large enough to collect the whole output bundle. Start with small cone angles so an ordinary relay approximates the area-angle tradeoff. Measure the patch's image diameter and the accepted angular extent at both conjugate planes; the transverse magnification gives the spatial scale, but does not by itself measure etendue.
Map the local radiance with a baffled photodiode on translation and rotation stages, using two small aligned holes to select a narrow known solid angle. Keep the sampled position fixed while scanning direction, calibrate the sampling footprint and angular response, and repeat at several positions. Numerically integrate over the occupied samples, and integrate to predict the collected radiant flux. This checks the filled-cone assumption instead of inferring it from two outer dimensions.
Compare the relay without a stop and with a stop of times the illuminated diameter in the same plane. The uniform-bundle prediction is a radiant flux ratio of , with unchanged local radiance in the surviving samples. Cover the input for a dark reading, monitor source drift, repeat the open-stop reading, check detector linearity with calibrated optical attenuators, and enlarge the collecting detector or scan it to check for missed light rays. Lens losses, angular response, illumination gradients, alignment errors and diffraction can spoil the ideal prediction; their effects must be measured separately. This is a procedure to try, with predicted readouts, not purported experimental data.
Field of view Created 2026-10-05 Updated 2026-10-14
The field of view is the region of object directions sampled by an optical instrument in one pointing. State whether it is horizontal, vertical or diagonal, and whether it is a full angle or a half-angle. An object-plane width in millimetres also describes a field of view, but requires a specified object distance. Neither that width nor the angular field of view is the aperture diameter or the diffraction-limited resolution.
For a centred flat rectangular photodetector of width in the focal plane, with positive effective focal length , infinity focus and ideal rectilinear imaging without optical distortion, the full horizontal field of view isThe model maps an object direction to image height of magnitude ; set and use the inverse tangent. This retains exact right triangle geometry within the stipulated imaging model; a paraxial focal length alone does not guarantee that a real wide-field optical lens obeys it. With detector height , replace by for the vertical field of view, and by for the diagonal field of view. The small-angle approximation gives in radians. [ref]
https://www.edmundoptics.com/knowledge-center/application-notes/imaging/understanding-focal-length-and-field-of-view/. Gregory Hollows and Nicholas James, Edmund Optics, Understanding Focal Length and Field of View
.For an original worked example, a detector width gives at , and at . Keeping makes these f/2 and f/4 respectively: the field of view changes because changes. By contrast, closing from to at changes f/4 to f/8 while retaining in this model. The clean separation is useful: entrance pupil area controls collection, focal ratio controls the paraxial cone, and controls angular image coverage. Edge clipping, optical distortion, field curvature and optical aberrations can restrict the practically usable field of view.
A proposed angular readout on an optical bench illuminates a small asymmetric target at the optical focus of a collimator, providing a bundle with a known direction. Rotate the optical camera about the centre of its entrance pupil, reading a graduated rotation stage, and record the target image position on its fixed photodetector. Centre the target to establish zero; turn left and right until its centre reaches each detector edge. The difference between stage readings measures the full horizontal field of view. Repeat with a smaller aperture stop: unchanged edge directions but reduced signal support the distinction between collection and angular coverage. Keep the same active detector width, infinity focus, illumination, integration time and gain; approach each reading from the same direction to check mechanical backlash. A finite target blurs the edge criterion, detector thresholds can imitate lost coverage, and a wide bundle must illuminate the whole entrance pupil at every tested angle. These checks distinguish a geometrical boundary from insufficient signal. The analytical diagram is the prediction for this protocol, not a record of its execution.
Focal ratio Created 2026-10-06 Updated 2026-10-14
The focal ratio, or f-number, of a converging optical instrument focused at infinity is the dimensionless quantitywhere is effective focal length and is the on-axis entrance pupil diameter. The notation f/4 means , not in a particular unit. A focal length with gives f/4. Closing the aperture stop until gives f/8 while retaining the same focal length. The mechanical opening need not equal . [ref]
https://www.edmundoptics.com/knowledge-center/application-notes/imaging/lens-iris-aperture-setting/. Gregory Hollows and Nicholas James, Edmund Optics, System Throughput, f-number, and Numerical Aperture
.For a thin lens in air with a circular aperture stop at the thin lens, the converging bundle from a distant on-axis point has half-angle satisfyingThe last step uses the small-angle approximation. For a compound optical lens, the cone is set by the image-side optical pupil and its distance from the receiving plane; the simple triangle is not an exact high-angle rule. At finite object distance a thin lens instead gives , by its imaging equation and transverse magnification, so its working cone corresponds to . Nominal focal ratio therefore does not alone specify close-range image irradiance. [ref]
https://www.edmundoptics.com/knowledge-center/application-notes/imaging/lens-iris-aperture-setting/. Hollows and James, working f-number and image-space cone
.Two useful scalings follow under stated conditions. For a fixed uniform incident beam and unchanged transmission, collected radiant flux scales as . For an extended source with fixed radiance, the central image irradiance scales approximately as in the paraxial approximation: the solid angle of the cone scales as . For an ideal uniformly illuminated unobscured circular entrance pupil, the first dark ring of the point spread function has angular radius and focal plane radiusHere is wavelength. These are first-zero radii, not diameters or a universal rule for resolving arbitrary objects. A proof outline evaluates the circular aperture's Fraunhofer diffraction using its Fourier transform, then uses the first zero of the resulting Bessel function. [ref]
Two-Dimensional Fourier Optics. Richard Fitzpatrick, University of Texas at Austin, Two-Dimensional Fourier Optics, circular-aperture first minimum
.At , the example's f/4 and f/8 first-ring radii are and . Closing the aperture stop halves , quarters collected radiant flux and doubles this diffraction radius. It can also reduce optical aberrations by excluding outer light rays; actual sharpness reflects both effects. This explains why a smaller aperture need not produce a sharper image. [ref]
https://www.edmundoptics.com/knowledge-center/application-notes/imaging/limitations-on-resolution-and-contrast-the-airy-disk/. Gregory Hollows and Nicholas James, Edmund Optics, The Airy Disk and Diffraction Limit
.Aperture and focal ratio: a common optical focus, reduced collection and increased diffraction radius
. Original analytical illustration. Left: equal-scale thin lens geometry with and or . Right: collected radiant flux relative to f/4 is , and first-ring radius relative to f/4 is . The wavelength is ; the entrance pupil is circular, uniformly illuminated and unobscured. These are calculated quantities, not measurements. Details.A proposed optical bench check puts a fixed collimator before a converging thin lens and a photodetector large enough to collect the entire image behind it. Compare two centred aperture stops of known diameters while fixing source output, detector gain and integration time. The integrated signal tests the collection law; a spatially resolved optical camera at the focal plane can separately measure the point spread function. Repeat a dark reading and the first aperture stop, and check that neither the incoming beam nor detector clips either bundle. A resolved pinhole source, imperfect collimation, optical aberrations and detector pixel size can dominate the apparent spot width; a single peak reading does not measure total collected radiant flux.
Optical bench Created 2026-10-14 Updated 2026-10-14
An optical bench is a rail or aligned platform carrying an object, optical lens elements and a screen or detector at readable positions. It turns image formation into measurements of position and transverse magnification. Read distances between the optical planes rather than arbitrary holder boundaries; keep heights and optical axis alignment controlled. [ref]
https://www.pasco.com/resources/lab-experiments/484. PASCO, Object and Image Distances Thin Lens: bench apparatus and measurements
. Real image 2026-10-14
A real image lies where the outgoing light rays from each object point actually intersect in geometrical optics. A screen or detector placed at that image plane receives the focused pattern. The screen reveals the real image; it does not create the intersection. A viewer can also see a real image without a screen if their eye receives the diverging light rays beyond the intersection. [ref]
https://openstax.org/books/college-physics-2e/pages/25-7-image-formation-by-mirrors. Urone and Hinrichs, College Physics 2e, §25.7: Real images and their observation
.For a converging thin lens and real object with , the real image has and signed transverse magnification . Inversion is a property of this particular setup, not the definition of a real image. With and , the following are predictions:
| Object distance | Image distance | Transverse magnification | Signed image height |
|---|---|---|---|
To test both image position and transverse magnification, use an optical bench with an illuminated arrow or millimetre target, a converging optical lens of nominal focal length , a movable white screen and a ruler. Measure corresponding target and image intervals, rather than guessing the whole image size when it exceeds the screen. PASCO's Experiment 12 compares distance-based and size-based magnification; the following procedure uses several object distances, as in the Northern Virginia laboratory. [ref]
https://tecnoedu.com/recursos/UNLCHidrologia/ManualesOriginalesPasco/Basic-Optics-System-Manual-OS-8515C.pdf. PASCO, Basic Optics System manual, Experiment 12, pp. 33–36
; [ref].- Align target centre, optical lens centre and screen along one optical axis, with target and screen perpendicular to it. Record bench positions of the actual target plane, optical lens plane and screen surface; distances between holder edges introduce an offset.
- Start at . Move the screen through the expected region until the target's central detail is sharpest. Record , measured , the corresponding target and image intervals, and whether the arrow is inverted. Give the measured size ratio a negative sign if inverted.
- Repeat at and . Compare the measured signed size ratio with , and calculate for each pair. The three ideal rows above are predictions to compare against, not entries to copy into the measurement record. [ref]https://sites.nvcc.edu/alphy/_files/Manuals/Physics%20242%20Lab%2011%20-%20Thin%20Lenses.pdf. Northern Virginia Community College, Physics 242 Lab 11, pp. 2–4: screen focusing, orientation and size measurements.
Keep the optical lens, illumination and central target detail fixed between trials. Approach best focus from both sides and record the interval over which sharpness is difficult to distinguish; repeat focusing to estimate its reproducibility. A modest central aperture stop tests whether peripheral light rays change the result, but also reduces brightness. Spherical aberration, chromatic aberration and diffraction can broaden the optimum; a thick optical lens also makes the chosen reference plane imperfect. Treat nominal as an initial prediction, and report position and interval-reading limits instead of forcing exact agreement. [ref]
https://www.feynmanlectures.caltech.edu/I_27.html. Feynman, Leighton and Sands, §§27-5–27-7: principal planes and imaging limits
.Moving the object toward the front optical focus from outside makes the real image larger and farther away. A failed screen search near can therefore mean that the real image is beyond the bench, rather than that a virtual image has formed. At exactly , the outgoing bundle from each point is parallel and no finite screen position focuses it.