Aleš Fajgelj 2026-11-05
Aleš Fajgelj is an analytical chemistry researcher whose work includes metrological traceability, recovery information and laboratory quality assurance. The 2011 IUPAC traceability report identifies his affiliation with the International Atomic Energy Agency's Department of Nuclear Sciences and Applications.[ref]
Metrological traceability of measurement results in chemistry: Concepts and implementation by Paul De Bièvre and others. Publisher byline and affiliation 3.
With Paul De Bièvre, René Dybkær and D. Brynn Hibbert, Aleš Fajgelj prepared recommendations intended to give chemical measurement a consistent account of the creation, meaning and role of metrological traceability. He also coauthored the 1999 recovery-information report, connecting the interpretation of laboratory results with the handling of losses during preparation.[ref]
Metrological traceability of measurement results in chemistry: Concepts and implementation by Paul De Bièvre and others. Abstract.
[ref]An original example illustrates the distinction between documenting a reference and validating a process. Suppose a standard solution's assigned concentration is connected to a specified reference through documented measurements. If an unknown loses 20% of its analyte during preparation while the standards do not, that documented standard alone does not justify treating the unknown's preparation loss as zero. The measurement model must represent the relevant stages and their measurement uncertainty.
Likewise, agreement in an interlaboratory comparison supplies evidence about the compared results, but does not by itself write the missing chain of reference relationships. The value of Aleš Fajgelj's standards work lies in making those distinctions explicit enough for laboratories to communicate what a result means.
Certified reference material 2026-11-05
A certified reference material is a reference material supplied with authoritative documentation assigning specified property values and their associated uncertainties and traceabilities through valid procedures. The certification applies to the stated properties and conditions. It does not make every conceivable property of the material a certified value.[ref]
A usable certificate identifies the material and relevant property, its assigned value, the uncertainty convention, conditions of use and the evidence needed for metrological traceability. Both reference material homogeneity and reference material stability matter when a portion is used later. The VIM distinguishes reference materials suitable for precision control from those with assigned values suitable for measurement calibration or measurement trueness control.[ref]
International vocabulary of metrology by JCGM. VIM3entry5.13, note2
For a physical example, the archived NIST SRM1922 mineral-oil certificate gives refractive index at and , with expanded uncertainty and coverage factor .[ref]
Certificate for Standard Reference Material 1922 by National Institute of Standards and Technology. 2009certificate, p1, uncertainty convention; p2, Table1, fitted589.3nm entry
Its corresponding standard uncertainty is .For an original comparison under those same conditions, suppose a refractometer gives with independent standard uncertainty . The discrepancy is , and its combined standard uncertainty isThus the discrepancy is . This calculation is a diagnostic comparison, not an automatic pass/fail rule. Correlated contributions, a different temperature or an inappropriate sample invalidate the simple comparison model. The certificate supplies a documented reference and its limits; the user's complete measurement result still includes the measuring instrument and procedure.
David Brynn Hibbert 2026-11-05
David Brynn Hibbert, also known as Brynn Hibbert, is an analytical chemistry researcher whose work combines chemometrics, electrochemical measurements and metrological traceability. His university profile records his tenure in the UNSW analytical-chemistry chair from1987 to2013 and his editorship of the IUPAC terminology compendium known as the Orange Book. The Royal Society of New South Wales explicitly verifies his full name.[ref]
David Brynn Hibbert profile at UNSW. Institutional research summary; linked Presidents’ Profiles, printed p.93, DAVID BRYNN HIBBERT.
With Paul De Bièvre, René Dybkær and Aleš Fajgelj, David Brynn Hibbert coauthored the IUPAC report on the concepts and implementation of metrological traceability in chemical measurement. Its goal was a consistent account of how a result is related to a reference, including the concepts needed to communicate that relationship.[ref]
An original illustration explains the value of a measurement model in chemometrics. Suppose two ideal sensors give and , where is the target concentration and an interfering response. Their mean recovers , while their difference diagnoses . If both instead respond as , averaging cannot remove the interference. The chemical response model determines what additional measurements identify; having more numbers alone does not guarantee more independent information.
David Brynn Hibbert, portrait identified by his UNSW profile
. Measurement result 2026-11-05
A measurement result comprises the values attributed to a measurand together with the information needed to interpret those values. It commonly takes the form of a measured quantity value and its measurement uncertainty, but the result can contain a fuller probability distribution. A displayed number alone need not supply this information.[ref]
For an original electrical resistance example, report a corrected value at , with standard uncertainty . Specify that the uncertainty is a standard uncertainty, identify the resistor and the temperature condition, and retain the measurement procedure and measurement calibration records. Writing only “100.020” omits both the unit and the meaning of the last digits. Writing without stating what the second number represents is also incomplete.
An alternative report might use expanded uncertainty with coverage factor . This is a different uncertainty convention for the same central estimate; it is not a newly observed change in the resistor. A probability interpretation requires the distributional assumptions accompanying that convention.
An instrument's indication, a corrected measured quantity value and the complete measurement result therefore play different roles. Corrections from the measurement model, the specified measurand, environmental conditions and metrological traceability can all matter when comparing results. Extra displayed digits cannot replace the omitted measurement uncertainty.
Measurement standard 2026-11-05
A measurement standard realizes a specified quantity with an assigned value and associated measurement uncertainty, and is used as a reference. It can be a physical artifact, a measuring system or a suitable reference material. The value and its measurement uncertainty apply under stated conditions and at the relevant time; a nominal label alone is insufficient.[ref]
For an original comparison, take a reference resistor with assigned electrical resistance and standard uncertainty . A comparison measures a working resistor's ratio , with independent . The measurement model givesand first-order propagation of uncertainty givesThe reference's measurement uncertainty remains in the result even if the ratio could be read with arbitrarily many digits.[ref]
A practical comparison records reference conditions, connecting arrangements and repeated readings while checking effects such as instrumental drift. A primary measurement standard has a particular basis for its assigned value; a working reference need not be primary to transfer useful metrological traceability. Distinguish this physical reference from a written technical specification, which is another use of the word standard.
Medical physics 2026-11-05
Medical physics applies physics to quantitative problems in medical imaging, nuclear medicine and radiation therapy. It connects an instrument's signal to a physical quantity, tests the model behind that inference, and establishes its measurement uncertainty. Examples include reconstructing an image from radiation or acoustic measurements and determining the absorbed dose delivered by an ionizing radiation beam.
The sealed-water calorimeter of Steve R. Domen gives a concrete measurement example. Domen's 1994 study placed sealed water in a glass cylinder, 110 mm long and 33 mm in diameter, inside a 30 cm water-filled acrylic cube. Two calibrated thermistors formed opposite arms of a Wheatstone bridge; their change in electrical resistance measured the small temperature rise. The glass also limited convection.[ref]
A Sealed Water Calorimeter for Measuring Absorbed Dose by Steve R. Domen. Sections1–2, pp.121–122: measurement principle, bridge and glass-container geometry
In the ideal water calorimetry balance, deposited energy becomes heat, givingwhere is absorbed dose and specific heat capacity. Using a rounded illustrative , depositing in corresponds to one gray and onlyThis small signal makes thermal control and measurement calibration central to the experiment.
Domen also investigated the heat defect: radiation-induced chemistry can release or store energy, changing the heat readout. Approximately 3700 measurements varied dissolved-gas conditions and compared the response with other calorimeters. The test examined whether a measured temperature rise represented the intended absorbed dose, rather than assuming the equivalence.[ref]
A Sealed Water Calorimeter for Measuring Absorbed Dose by Steve R. Domen. Abstract and Sections7–8: gas-dependent heat defect, comparisons and uncertainty assessment
Metrological traceability connects such measurements through documented calibrations and their measurement uncertainties. In the IAEA/WHO network, national laboratories and secondary-standard laboratories link reference dosimeters to the instruments used in practice. A primary measurement standard supplies the reference realization; the calibration chain transfers it to other instruments.[ref]
Medical Physics and Dosimetry by the IAEA. Main text: national laboratories, secondary standards and end-user dosimeter calibration
Metrological traceability 2026-11-05
Metrological traceability is a property of a measurement result: a documented, unbroken sequence of measurement calibrations relates it to a stated reference, and every link contributes to its measurement uncertainty. The reference can be a practical realization of a measurement unit, a measurement procedure or a measurement standard.[ref]
Consider an original mass-measurement chain: a reference measurement standard calibrates a working mass, which is used for instrument calibration of a balance, which weighs an object. Suppose the reference contributes of standard uncertainty, the transfer adds an independent , and the final weighing adds an independent . With unit sensitivity to these additive contributions,The intermediate working mass has of standard uncertainty. That value already includes the reference contribution; adding the same again at the final step would double-count it. Correlated contributions require covariance terms rather than the independent-input calculation.[ref]
Documentation must identify the reference, comparison procedures, dates, applicable conditions and uncertainty contributions. A certificate or instrument label alone does not supply the complete chain for every later result. Metrological traceability also does not ensure that the resulting measurement uncertainty is small enough for the intended use.
Paul De Bièvre 2026-11-05
Paul De Bièvre was a researcher in isotope ratio measurements, reference materials and chemical metrology. His IUPAC Council biography records leadership in isotope mass spectrometry and isotope reference materials at the European Commission's nuclear-measurement laboratory, later the Institute for Reference Materials and Measurements.[ref]
Paul De Bièvre nomination biography for the 43rd IUPAC Council. Professional Experience, group leadership and laboratory responsibilities.
With René Dybkær, Aleš Fajgelj and David Brynn Hibbert, Paul De Bièvre prepared the2011 IUPAC report on metrological traceability of chemical measurement results. The report's stated aim is a consistent view of traceability's creation, meaning and role in chemical measurement.[ref]
An original isotope-counting example shows why a ratio must be specified. If a hypothetical two-isotope material contains80 units of isotope A and20 of isotope B, its ratio A/B is4, while the fraction A/(A+B) is0.8. Multiplying a sample's total amount by ten changes neither value. An instrument response ratio still requires a measurement model relating its signals to those isotope amounts; unequal response to the two isotopes can alter the observed ratio.
This connects isotope measurements with reference material characterization and measurement calibration. A precise signal ratio is useful only when its relation to the specified measurand and reference is established, with appropriate measurement uncertainty. Paul De Bièvre's documented work joined those experimental and conceptual aspects.
Range-overlap calibration 2026-11-05
Range-overlap calibration establishes or checks the relationship between instrument settings using inputs that both can measure validly. In gain ranging, it tests whether changing sensitivity preserves the inferred measurand. It can determine relative scale and offset between ranges, but agreement between ranges alone does not establish their absolute accuracy or independent metrological traceability.
For an original two-range measurement model, let the same stable electric current produceEliminating givesAn overlap experiment therefore needs enough distinct, stable input levels to distinguish relative gain from offset. One common input gives one equation for and and cannot identify both without additional information.
For example, suppose , , and . Currents of , and give output pairs , and . They satisfy . Dividing raw outputs by their nominal gains without removing the offsets would not give consistent current estimates.
A practical test can drive a switchable transimpedance amplifier from a stable current source, record multiple overlap levels, and alternate the setting order to reveal instrumental drift. Avoid amplifier clipping, allow settling time, and retain the bandwidth and temperature conditions. The manufacturer tables show why range-dependent noise and gain drift must be included rather than assumed equal.[ref]
Datasheet DLPCA-200 by FEMTO. p. 2, gain accuracy, gain drift, input limits and gain-dependent performance
At each level, compare corrected estimates and through their difference . The measurement uncertainty of that difference depends on covariance:A common reference can move both estimates together and disappear from this difference. Thus good overlap agreement checks a relative relationship; it cannot by itself exclude a shared calibration error. The general uncertainty-combination law explicitly retains correlated contributions.[ref]
René Dybkær 2026-11-05
René Dybkær worked on measurement concepts and terminology in laboratory medicine. The IUPAC traceability report identifies him with the Department of Standardization in Laboratory Medicine at Frederiksberg Hospital, Denmark, and names him as a coauthor with Paul De Bièvre, Aleš Fajgelj and David Brynn Hibbert.[ref]
Metrological traceability of measurement results in chemistry: Concepts and implementation by Paul De Bièvre and others. Publisher byline, affiliation2 and Abstract.
The report develops a shared account of metrological traceability for chemical measurement. Such terminology matters because a result must identify the measurand and reference relationship before numerical comparisons become meaningful. A chemical name, number and unit together specify more than an instrument indication alone.
For an original conversion example, a stipulated compound with molar mass at has mass concentration . The numbers2 and200 describe equivalent content under that specification, rather than disagreement between laboratories. Conversely, equal numbers attached to different quantity definitions need not be equivalent. Uncertainty in the inputs also belongs in the conversion's measurement uncertainty.
René Dybkær's coauthored standards work addresses this need to make the meaning of a measurement communicable. The example is an original illustration of the problem, not data attributed to his experiments or a statement of a clinical decision threshold.