Core needle biopsy Created 2026-10-31 Updated 2026-11-05
A core needle biopsy removes a small cylinder of biological tissue through a hollow needle for examination, commonly by microscopy. Retaining a piece of tissue permits assessment of cellular arrangement as well as individual cells. It differs from merely imaging the region or sampling dissolved substances in blood. The specimen supplies evidence from the sampled location; its interpretation also depends on sampling adequacy and the surrounding clinical question. [ref]
Coronary artery 2026-11-05
A coronary artery is an artery supplying the heart's own tissues, especially the myocardium. The main left coronary artery and right coronary artery arise from the proximal aorta near the aortic valve. Their branches supply the working cardiac muscle rather than merely conveying blood through the heart's chambers.[ref]
Anatomy and Physiology 2e by J. Gordon Betts and others. Section 19.1, Heart Anatomy, Coronary Circulation and Coronary Arteries; Figure 19.15
This arrangement separates two circulations that can otherwise be confused. Blood inside a cardiac chamber is being pumped onward; coronary blood flow brings oxygen and other materials to the living wall doing the pumping. An open chamber and a patent large coronary artery therefore answer different anatomical questions. Distribution through smaller vessels and exchange with tissue also matter.
An original conservation calculation illustrates the supply problem. If coronary volume flow is and arterial oxygen content is , then coronary oxygen delivery isWith chosen values and , delivery is . If a representative venous oxygen content is , a steady-state inflow–outflow balance givesHere is the coronary oxygen extraction fraction. The example assumes matched inflow and outflow from the same represented tissue, with negligible oxygen accumulation; these are illustrative values, not clinical reference limits. Delivery and extraction distinguish a flow measurement from the tissue's oxygen use.
Vascular stenosis can change the supply route, while the observed consequence depends on more than one geometric percentage. Coronary angioplasty targets a narrowed arterial segment. The historical primary study measured both stenosis and the pressure difference across the affected region, making anatomy and a physiological observation available together.[ref]
Nonoperative dilatation of coronary-artery stenosis: percutaneous transluminal coronary angioplasty by A. R. Grüntzig and others. Abstract, paired stenosis and pressure observations
Neither observation by itself supplies all the information in the oxygen balance above. Coronary artery disease Created 2026-10-31 Updated 2026-11-05
Coronary thermodilution mixing assumptions 2026-11-05
Coronary thermodilution mixing assumptions are the conditions that make a downstream temperature reading representative of the mixture used to infer coronary blood flow. They include adequate mixing of infused fluid and blood, appropriate volumetric heat capacity values, known infusion rate and temperature, and sufficiently small unmodeled heat transfer between the fluid and surrounding structures.
The apparatus places these assumptions in a concrete setting. In a primary continuous-infusion study, a catheter supplied room-temperature saline while a pressure/temperature guidewire measured distal temperature; the infused-fluid temperature was measured at the catheter tip.[ref]
Direct volumetric blood flow measurement in coronary arteries by thermodilution by Wilbert Aarnoudse and others. Abstract, Methods
Temperature at the tip matters because fluid can exchange heat before entering the measured blood flow.An original two-stream model makes the bookkeeping explicit. Let native blood flow be , infusion rate , baseline blood temperature , infused-fluid temperature and mixed temperature . Assume equal constant volumetric heat capacity, no external heat transfer and steady complete mixing. Conservation of energy givesand henceNative flow and total downstream mixture flow have different numerators. With constructed mL/min, , and , the model gives mL/min and mL/min. This equal-capacity balance is an explanatory model, not the instrument's full calibration algorithm.
Incomplete mixing changes what the sensor observes. If a sensor sampled an unusually cold filament and read for the same other inputs, the formula would return about mL/min instead of 80. Repeating that local reading precisely would not correct its lack of representativeness. More generally, a mixed temperature is weighted by transported heat capacity, rather than being an unweighted spatial mean.
Finally, becomes sensitive to small temperature errors when is small. At fixed ,For the constructed example this is mL/(min K). The derivative describes local sensitivity within the model; it does not estimate errors from incomplete mixing or heat loss. Those require separate physical evidence.
Corpus luteum 2026-11-05
The corpus luteum is a temporary endocrine structure formed from the ovarian follicle after ovulation. Its luteinized cells produce substantial progesterone, helping maintain the secretory state of the endometrium. Without sustained hormonal support it regresses; in early pregnancy, human chorionic gonadotropin helps preserve its steroid production.[ref]
Anatomy and Physiology 2e by J. Gordon Betts and others. Section 27.2, ovulation, corpus luteum and ovarian-cycle hormone changes
It illustrates that an endocrine gland need not be a permanently separate organ. A local tissue is reorganized into a hormone-secreting structure and later changes again. A measured progesterone concentration reflects both this production and removal from the blood, so it is not a direct count of luteal cells.
Countercurrent exchange 2026-11-05
Countercurrent exchange is transfer of heat or material between adjacent streams moving in opposite directions. The opposing countercurrent flow can maintain a useful local driving difference along an exchanger. In a heat exchanger, a wall permits heat transfer while keeping the fluids separate; in the renal vasa recta, exchange with the surrounding medulla helps retain solute while blood circulates.[ref]
DOE Fundamentals Handbook Thermodynamics Heat Transfer and Fluid Flow Volume 2. HT-02,pp30–33: counter-flow geometry and temperature profiles
An ideal steady model gives a worked example. Suppose the two streams have equal constant heat-capacity flow rate , no heat escapes elsewhere, and their total thermal conductance is . If is the transferred thermal power, the energy balances giveEqual capacity rates make the local temperature difference constant in this ideal counter-flow model. Thus , and substitution yieldsFor , and inlet temperatures and , the result is . The hot outlet is and the cold outlet is . At either end the streams beside one another still differ by ; the two outlets are at opposite ends.[ref]
DOE Fundamentals Handbook Thermodynamics Heat Transfer and Fluid Flow Volume 2. HT-02,pp36–39: heat balance and overall conductance relation; numerical values here are illustrative
The arrangement neither creates energy nor pumps heat from a colder neighboring fluid to a hotter one. Flow geometry determines which local states interact. In the kidney, that distinction also separates exchange preserving a medullary gradient from the energy-dependent transport contributing to countercurrent multiplication.
Cupping 2026-10-31
Application of a cupping vessel to produce local suction. Dry cupping uses intact skin; wet cupping includes incisions and removal of blood. This procedural distinction does not itself establish therapeutic efficacy. [ref]
Cyanide poisoning Created 2026-10-31 Updated 2026-11-05
Toxic injury in which cyanide impairs cellular oxygen use, including through inhibition of cytochrome c oxidase. Oxygen can be available in blood while tissues fail to use it effectively, distinguishing the mechanism from simple lack of inspired oxygen.[ref]
Cyanide chemical fact sheet by CDC. Mechanism and health effects
Cyanosis Created 2026-10-31 Updated 2026-11-05
A blue or dusky appearance caused by changes in the pigments of blood visible through tissue, often associated with increased deoxygenated hemoglobin. Visible color is an imperfect indicator of tissue oxygenation and depends on the blood circulation and hemoglobin concentration.
Diabetes Created 2026-10-13 Updated 2026-11-05
A group of metabolic disorders characterized by persistently elevated blood glucose due to inadequate insulin secretion, action or both. Its forms differ in mechanism despite the shared glycemic result.[ref]
What Is Diabetes by NIDDK. Definition and types
Digoxin Created 2026-10-31 Updated 2026-11-05
Digoxin is a cardiac glycoside that inhibits sodium-potassium ATPase. The resulting changes in ion handling influence cardiac contraction and conduction. Blood concentration, tissue exposure and clinical response are related measurements with different time courses.[ref]
Dilated cardiomyopathy 2026-11-05
Dilated cardiomyopathy is a form of cardiomyopathy involving enlargement of a ventricular chamber together with impaired pumping by the heart muscle. The left ventricle is a central site of the disorder, and other chambers can also be affected. Enlargement and pumping function are related but distinct observations; chamber size alone does not determine how much blood is expelled.[ref]
Cardiomyopathy Types by NHLBI. Dilated cardiomyopathy: enlarged, weakened ventricles and reduced pumping
A simple volume example makes that distinction quantitative. Let end-diastolic volume be and end-systolic volume be . ThenHere SV is stroke volume and EF is ejection fraction. A stipulated chamber changing from to ejects with EF . Another changing from to ejects with EF . A larger filled volume need not produce a larger stroke volume. These are constructed mechanical examples, not diagnostic cutoffs or reference ranges.
Imaging can test several parts of this mechanism. Echocardiography follows chamber dimensions and contraction; cine magnetic resonance imaging can quantify volumes and longitudinal motion. In a primary study, Marcus Carlsson and colleagues compared twelve patients with dilated cardiomyopathy, twelve controls and twelve elite triathletes. Their analysis combined atrioventricular-plane displacement with anatomical area to investigate the longitudinal contribution to ventricular pumping.[ref]
Atrioventricular plane displacement is the major contributor to left ventricular pumping in healthy adults, athletes, and patients with dilated cardiomyopathy by Marcus Carlsson and others. Abstract, Methods: cine imaging and the three twelve-person groups
This experiment illustrates why the condition cannot be represented by one chamber diameter alone: geometry, motion and transported volume supply different information. Doppler echocardiography and its velocity-time integral provide complementary flow observations, while a clinical diagnosis also requires the surrounding evidence and cause of the myocardial abnormality.
Diuretic therapy Created 2026-10-31 Updated 2026-11-05
Treatment intended to increase urine output. Current guidance uses monitored diuretic therapy for acute heart failure; it is distinct from loss of blood through venesection. [ref]
Doppler ultrasonography Created 2026-10-31 Updated 2026-11-05
Doppler ultrasonography applies Doppler ultrasound to motion within the body, especially flowing blood. Moving scatterers change the returned frequency or phase; the shift measures a component of velocity along the acoustic geometry. Combining that information with ultrasonography locates motion relative to the imaged structures.[ref]
Venous Ultrasound by RadiologyInfo.org. What is Venous Ultrasound Imaging?: Doppler measurement of moving materials and blood flow
A color map assigns a display color to a measured flow quantity under a chosen sign convention. It therefore represents an inferred motion, rather than the literal optical color of the blood. Estimating a speed requires the beam-to-flow angle and the assumptions behind the Doppler ultrasound measurement; a small shift can reflect a nearly transverse flow as well as a small speed.
Drug distribution 2026-11-05
Drug distribution is movement of a drug between blood and other body compartments. Perfusion, membrane permeability, tissue binding and plasma-protein binding jointly affect it. The apparent distribution volume iswhere is the amount in the body and the plasma concentration. If mg and mg/L, L. [ref]
Population Pharmacokinetics Guidance for Industry by the FDA. 2022, pharmacokinetic parameters and concentration-time models
The result is a proportionality quantity, not an anatomical cavity that must contain that many litres. Extensive tissue binding can lower and make large. A rapid fall in plasma concentration immediately after administration can therefore reflect distribution as well as drug elimination; distinguishing them requires a model and a suitable sampling schedule.
Drug elimination 2026-11-05
Drug elimination removes a parent drug from the body's measured parent-drug pool through drug metabolism or excretion. Redistribution from blood to a tissue changes plasma concentration but does not by itself eliminate the drug from the body. A mass balance separates input, output and transfers between compartments. [ref]
Population Pharmacokinetics Guidance for Industry by the FDA. 2022, pharmacokinetic model development and concentration-time analysis
For a one-compartment model with no input and first-order elimination, gives . Equal fractions disappear in equal time intervals. By contrast, a saturated elimination route can approach removal of equal amounts per interval. The latter produces a different concentration-time curve and cannot be assumed to have a concentration-independent half-life.
Dry cupping 2026-10-31
Application of suction cups to intact skin, without the incisions used in wet cupping. It therefore does not itself constitute removal of blood. [ref]
Embolism Created 2026-10-31 Updated 2026-11-05
End-diastolic volume 2026-11-05
End-diastolic volume is the volume of blood in a specified ventricle at the end of filling, before the subsequent ejection. It is the starting volume in the usual volumetric stroke volume calculation and the denominator of ejection fraction:The right ventricle and left ventricle each have their own end-diastolic volume. The chamber, phase and measurement convention must be identified before two values are compared.
For a constructed example, a chamber filling to 120 mL and ending ejection at 50 mL has a stroke volume of 70 mL and ejection fraction about . Another chamber filling to 180 mL and ending at 110 mL has the same 70 mL stroke volume, but ejection fraction about . Equal ejected volumes do not imply equal relative emptying.
The quantity can be obtained from time-resolved images by choosing the filling phase and identifying the complete cavity. A primary right-ventricular magnetic resonance imaging study generated volumes from cine images with three-dimensional modelling; its reference analysis also considered age, sex and body size.[ref]
Reference right ventricular systolic and diastolic function normalized to age, gender and body surface area from steady-state free precession cardiovascular magnetic resonance by Alicia M. Maceira and others. Abstract, Methods and results
These factors help explain why an isolated volume should not be treated as a universal reference value.For a simple sum-of-slices model, , where is the measured cavity area in a slice and its represented thickness. Omitting a slice with area 10 cm and represented thickness 0.8 cm omits about 8 mL. This example connects image segmentation and coverage to a concrete volume error; it does not require a spherical ventricle.
Endocrine gland 2026-11-05
An endocrine gland releases hormones into the surrounding internal fluid for delivery to target tissues, commonly through the blood. Unlike an exocrine gland, it does not use a duct to discharge its hormonal secretion onto an epithelial surface or into an anatomical lumen.[ref]
Anatomy and Physiology 2e by J. Gordon Betts and others. Section 17.1, Structures of the Endocrine System
The thyroid and pituitary are examples. The pancreas shows why classification can be functional: its endocrine cells release hormones such as insulin, while other pancreatic cells send digestive secretion through ducts. Hormone delivery alone does not specify the response. A target cell's receptors and intracellular signaling determine whether and how it reacts, and feedback can regulate further secretion.