Separable differential equation Created 2026-09-28 Updated 2026-10-14
A first-order ordinary differential equation is separable if its explicit form factors as . On an interval where , write and take antiderivatives to obtain an implicit solution:An initial condition determines and selects a branch and domain. The useful simplification is that the two integrals each involve only one variable, even when the original equation is nonlinear.
For Newton's law of cooling, division by gives . To keep the logarithm dimensionless, integrate relative to the initial excess temperature:When , continuity preserves the sign of the excess temperature until any potential zero, giving . This formula never reaches zero at finite time. Taking its derivative verifies the ordinary differential equation, and substitution at verifies the initial condition.
Always check what division removed. Each zero gives a constant solution of a differential equation . Cooling therefore also has the equilibrium point , omitted by division but included in the final explicit formula. For the nonunique initial value problem , division by only describes the moving pieces: a valid solution may remain zero for an arbitrary time before joining one. Separation is a method for finding solutions, not a uniqueness theorem.
For a long homogeneous circular wire of radius , uniform volumetric heating , constant thermal conductivity and negligible end losses, the steady heat equation is . Regularity at the axis excludes a logarithm term, giving . If the surface obeys Newton's law of cooling, , then . Here has units and has units . For uniform electric current and constant electrical conductivity , Joule heating gives .
Thermometer Created 2026-10-14 Updated 2026-10-14
A thermometer measures temperature through a physical response whose relation to temperature is known. Examples include the length change from thermal expansion, a change in electrical resistance, and the pressure of a gas thermometer. If the response function is an injective function over the working range, its measured value determines through the inverse function. Thermometer calibration establishes that relation for the particular instrument and measurement conditions. Two matching readings are meaningful only after calibration to a common scale and with the probes sampling comparable equilibrium states. [ref]
https://openstax.org/books/university-physics-volume-2/pages/1-2-thermometers-and-temperature-scales. Ling, Moebs and Sanny, University Physics Volume 2, section 1.2: physical responses used in thermometers
For a contact thermometer, the sensing part must reach thermal equilibrium with the region being measured. That region may differ from the rest of the object: an immersed probe near a heater can read a local temperature while the surrounding water remains cooler. A stable reading can also be a steady state set by competing heat transfer paths to the sample and the room. Good contact, adequate immersion, mixing where appropriate, and checks for spatial differences help establish which temperature the reading represents. These are measurement controls inferred from the thermal equilibrium requirement, not a guarantee that every flat trace is equilibrium.
A thermometer also changes the sample it touches. Consider an original toy calculation with an initially uniform sample at , a probe at , and constant whole-body heat capacities and . Suppose together they form an isolated system, with no work or phase transition and negligible contact energy. The first law of thermodynamics and thermal equilibrium giveThe final thermometer reading underestimates the sample's original temperature by about , although it correctly measures their new common temperature. The disturbance becomes small when the participating probe heat capacity is small compared with the sample's. A large controlled heat bath is a different limit: it supplies or removes heat while approximately maintaining its own temperature.
Waiting time is a separate issue from disturbance. Under a toy Newton's law of cooling model for a uniform probe in a maintained heat bath, a constant contact conductance givesThe time constant controls this exponential decay. For stipulated values , and , the probe reads about after one time constant and after three. These are calculated values, not an instrument specification or measured data. Real probes may have multiple relaxation times and additional heat transfer paths; choose an equilibration criterion from the required accuracy, rather than assuming that a fixed waiting time works universally.