Adiabatic process Created 2026-09-24 Updated 2026-10-14
An adiabatic process has no heat transfer across the chosen boundary throughout the process: , rather than merely zero net heat after incoming and outgoing transfers cancel. It is a condition on energy transfer, whereas an isothermal process holds temperature constant. A sealed cylinder can approach an adiabatic process through insulation or through motion short compared with the time needed for appreciable heat transfer. Its temperature can nevertheless change because work crosses the boundary.[ref]
Take the trapped gas as a closed system, with fixed amount of substance and composition and no net change in bulk kinetic energy or potential energy between the endpoints. Define as heat entering and as work delivered to the surroundings. The first law of thermodynamics gives
Here is internal energy. An adiabatic compression normally supplies work, so ; an adiabatic expansion against a resisting load delivers work, so . An adiabatic process need not preserve internal energy and need not make the closed system an isolated system. [ref]
For a reversible thermodynamic process, at positive absolute temperature . A reversible adiabatic process therefore has : it is an isentropic process. Irreversible adiabatic processes can instead generate entropy; free expansion is the existing counterexample, with its calculation in entropy change in free expansion. Conversely, constant entropy alone does not certify an adiabatic process or reversibility: outward heat can export the entropy generated internally. For a closed system the macroscopic entropy balance is
where is the absolute boundary temperature where each heat transfer occurs and is internal entropy production. With no heat transfer, this reduces to ; reversibility makes . [ref]
A motivating experiment measures the gas temperature directly during compression and expansion, instead of inferring it from how warm a cylinder feels. PASCO's authored TD-8565 manual describes a sealed piston cylinder, a fine nickel-wire thermometer, an absolute pressure sensor and a position readout for volume. A computer records all three channels together. The wire's electrical resistance changes with temperature; its small size permits a rapid response. [ref]
Use ordinary trapped air and the apparatus's designed travel stops; mount the base securely, close the valve during a stroke, and record the actual volume limits. John Hart's university demonstration uses a large transparent cylinder with a low-heat capacity thermocouple, a pressure sensor, a travel gauge and a safety stop. It explicitly keeps the release valve closed during the demonstration. The basic observable is a rise in temperature on compression and a fall on loaded expansion, alongside the corresponding pressure and volume changes. Hart discusses wall thermal conduction, sensor response and leakage as reasons real records differ from the reversible model. [ref]
For a proposed rapid-versus-slow comparison, let the air and walls return to the same initial thermal equilibrium before each run, then compare the same starting and finishing volume values with different stroke durations. Read temperature, absolute pressure and position continuously, including the hold after motion stops. A rapid compression gives a temporary temperature rise; holding the smaller volume lets heat leave and the temperature approach the surroundings again. Slow compression in good thermal contact allows that heat transfer during the stroke and approaches an isothermal compression. Loaded expansion reverses the signs: the rapid stroke cools, while heat entering during slow motion reduces the cooling. PASCO explicitly supports rapid nearly adiabatic processes and slow isothermal processes; the matched-run controls here are a proposed extension, not a reported set of measurements. [ref]
Insulation suppresses thermal conduction; it does not prove that heat transfer vanishes. As proposed controls, repeat the matched strokes with and without a removable insulating jacket, record room and wall temperatures, measure fixed-position drift, and check valve closure and seal leakage. Calibrate the thermometer and position readout independently, including any connected dead volume; account for the heat capacity of the probe rather than treating it as a passive observer. Hart explicitly identifies the small air sample relative to the probe and walls, sensor inertia and seal leakage as limitations. A fast display cannot eliminate those physical effects. [ref]
There are two distinct timing requirements. Let describe internal equilibration, the thermometer response, the stroke duration and the effective heat transfer time constant. A useful sufficient window for a resolved, nearly reversible adiabatic process is
with negligible friction. The left inequality permits a quasistatic process and a usable readout; the right limits heat leakage. A violent stroke may satisfy only the right inequality. PASCO reports a roughly – lag of its temperature channel behind the other channels, so apparent simultaneous samples require care. If no such window exists, analyze equilibrium endpoints with the first law of thermodynamics, and regard the path as approximate. [ref]
Figure 1. . Original apparatus schematic and analytical fixed-volume relaxation model, not measured records. After a stroke and internal equilibration, the stipulated Newton's law of cooling model gives . The positive and negative curves illustrate the holds after compression and loaded expansion. The drawing is a generic sensor arrangement, not a reproduction of a commercial device; it distinguishes the small probe from the walls and their possible heat transfer. Details.
The diagram's model is deliberately a hold after the stroke, when boundary work is zero. For constant whole-sample heat capacity at constant volume and effective thermal conductance , it assumes
This is Newton's law of cooling with one uniform gas temperature and a fixed surrounding temperature; actual wall and probe dynamics can require more than one time constant. At , the fraction of the initial temperature anomaly erased is ; at one time constant it is about . These are analytical fractions, not experimental tolerances or evidence that the preceding stroke was reversible. Measuring the hold helps estimate heat leakage independently of the motion.
The usefulness of an adiabatic process is that it separates mechanical work from heat transfer. Its reversible limit connects temperature changes, mechanical stiffness and entropy in one model: Rüchardt experiment and Clément-Desormes experiment already use that connection to measure heat capacity ratio. The contrast with free expansion explains the deeper point: suppressing heat does not determine how much work is exchanged or how much entropy is produced.
Free expansion Created 2026-10-14 Updated 2026-10-14
Free expansion occurs when a gas spreads into an initially evacuated region without driving an external load. The standard idealization uses a rigid, insulated vessel: initially a partition confines the gas to volume , while the remaining compartment contains vacuum. Open a passage and wait for thermodynamic equilibrium; the same fixed amount of substance now occupies the larger accessible volume . The outer vessel never changes size. This simple release separates three questions: what energy is conserved, whether temperature changes, and why entropy increases. [ref]
Figure 1.
Free expansion changes the accessible volume; the apparatus affects the observed temperature
. Original schematic, with equal compartments chosen for illustration. The top row assumes an insulated gas with negligible wall heat capacity. The bottom left sketches the water-bath arrangement of Joule's free-expansion experiment, rather than a reconstruction to scale. The bottom right uses stipulated heat capacities and an illustrative energy demand to show signal suppression; it contains no measured data. Details.
Choose the gas as the closed system, neglect heat exchange with the walls, and assume negligible changes in bulk kinetic energy and potential energy between the equilibrium endpoints. Insulation gives ; no moving outer boundary or external load receives work, so . The first law of thermodynamics therefore gives
The gas can develop internal motion during the release; this does not supply external work. The intermediate state need not have one equilibrium pressure or temperature, so there is no actual quasistatic process curve to integrate. In particular, substituting the equilibrium ideal gas law into would describe a different process. [ref]
For an ideal gas, internal energy of an ideal gas depends only on temperature. With positive heat capacity at constant volume, implies , and the ideal gas law gives . Doubling the accessible volume thus halves the final pressure without changing the final temperature. This is an endpoint statement; it does not assert a spatially uniform, constant temperature during the rush. Insulation alone does not imply constant temperature: a reversible adiabatic expansion cools an ideal gas because it supplies work. [ref]
For a real gas, can depend on volume as well as temperature, so unchanged internal energy need not mean unchanged temperature. For a fixed-composition simple compressible system in a single thermodynamic phase, equilibrium identities using a Maxwell relation give
Here is the whole sample's heat capacity at constant volume. The sign depends on the equation of state; for an ideal gas the numerator vanishes. For a finite free expansion, solve , or integrate this slope along equilibrium states of equal internal energy; that mathematical curve does not describe the actual release. [ref]
Free expansion is useful because it tests how internal energy depends on number density while eliminating external expansion work. Its beautiful surprise is that an ideal gas can finish with the same temperature and internal energy but greater entropy: a thermometer alone cannot diagnose reversibility. See entropy change in free expansion for the calculation and temperature sensitivity of a free-expansion experiment for the experimental qualification. The continuous-flow throttling associated with the Joule-Thomson coefficient has a different balance: under its usual assumptions it preserves enthalpy, whereas the gas-only idealization here preserves internal energy. [ref]