Virial expansion Created 2026-09-24 Updated 2026-10-13
The virial expansion describes the first departures from the ideal gas law as a power series in number density. For a homogeneous, single-species gas in three dimensions at thermal equilibrium, write , with the volume, and define the dimensionless compressibility factor byHere is absolute pressure, is absolute thermodynamic temperature, and is the Boltzmann constant. The second virial coefficient determines the initial slope away from ; higher coefficients describe further corrections. The symbol here is an equation of state ratio, not a canonical partition function. [ref]
Controlled gas expansion and extraction of a dilute-gas slope: schematic apparatus and explicitly chosen toy curves
. Details. The left panel sketches the measurement principle; the right panel uses deliberately chosen polynomials, with and , where is a reference length. These curves are not measured data. Their initial slopes have opposite signs, but both bend because of the quadratic term. Using a finite secant from to gives , rather than : reducing the fitting range reduces this particular truncation bias. This algebra explains why measuring one nonideal pressure is insufficient to extract a reliable second virial coefficient.
Waxman and Hastings's 1971 Burnett experiment used sample and expansion chambers in a thermostatic bath, with a valve between them and a pressure transducer linked to a piston gauge. They measured successive isothermal expansions: evacuate the expansion chamber, open the valve, record the equilibrated pressure, isolate and evacuate that chamber again, then repeat. This avoids separately measuring the absolute gas amount and chamber volumes. For carbon dioxide at , their measurements below bar gave a molar second virial coefficient of approximately . [ref]
https://nvlpubs.nist.gov/nistpubs/jres/75C/jresv75Cn3-4p165_A1b.pdf. Waxman and Hastings, Journal of Research of the NBS 75C (1971), pages 165–176, abstract and apparatus
An idealized reduction makes the signal explicit. Let be the calibrated chamber volume ratio, the pre-expansion pressure, and the post-expansion pressure. Particle conservation during one valve opening gives . At the same temperature, division of the two equations of state yieldsThus the intercept determines , while the dilute-limit slope determines the second virial coefficient. In the actual experiment, helium runs calibrated the cell constant and chamber deformation corrections were included. Agreement of the carbon dioxide low-pressure intercept with the helium calibration, and the absence of an anomalous low-pressure upturn, checked for gas adsorption on chamber walls. [ref]
https://nvlpubs.nist.gov/nistpubs/jres/75C/jresv75Cn3-4p165_A1b.pdf. Waxman and Hastings (1971), data reduction and adsorption checks, especially equation 13 and page 176
For a limited dilute-gas fit, hold temperature fixed, allow thermal equilibrium after every expansion, calibrate absolute pressure and the chamber ratio, and check leaks and sample composition. Repeat the analysis with a smaller upper pressure cutoff and an added curvature term; compare the resulting second virial coefficients with their uncertainties. Too wide a range mixes in higher coefficients; too narrow a range makes the nonideal signal hard to distinguish from instrument error. The displayed chamber equation neglects deformation, dead spaces and adsorption, so it is a teaching reduction rather than the complete experimental analysis.
Units matter. With number density in , has units and has units . For molar density in , the same equation of state isHere is the Avogadro constant and is the molar gas constant; the molar coefficients have units and . A coefficient tabulated per mole must therefore multiply molar density, not number density.
For the classical formulas below, use a nondegenerate gas with thermal de Broglie wavelength satisfying , negligible quantum corrections to relative motion, and a stable, sufficiently short-ranged pair potential. Diluteness must also control the omitted interaction terms: alone is not enough when positive and negative contributions cancel. A finite truncation is a local low-number density approximation, not an equation of state for a dense liquid or across a phase transition. [ref]
https://davidtong.org/teaching/statistical-physics/statmechhtml/S2#S2.S2.SS4. Tong, section 2.2.4: classical-density condition
[ref]https://davidtong.org/teaching/statistical-physics/statmechhtml/S2#S2.S5.SS1. Tong, section 2.5.1: dilute interacting gas
NASA's Wind Tunnel Experiment Details, slide 27, describes a practical manometer measurement: partially fill a Tygon tube with water and connect its two ends to total pressure and static pressure ports in a wind tunnel. The total pressure connection pushes its liquid meniscus downward; the vertical length difference supplies the pressure difference. The slide predicts increasing separation as the tunnel speed increases. It supplies an apparatus and method, rather than a table of observed readings.[ref]
Wind Tunnel Experiment Details, slide 27 by NASA Glenn Research Center. Wind Tunnel Experiment Details, slide 27: water-filled Tygon tube, total/static pressure ports and height readout
A control for this practical is to expose both connections to the same atmospheric pressure before the run: settled liquid meniscus heights should agree in a symmetric column. Read each liquid meniscus at eye level, reconnect sealed tubing to the identified ports, and wait for settling. Recheck the equal-pressure zero afterwards; reverse connections to check the sign. These checks establish neither mass density nor ruler accuracy.[ref]
University Physics Volume 1 by William Moebs and others. §14.2, Manometers, Figure 14.12(a): both arms open to atmosphere
The inference is a differential pressure from hydrostatic pressure, with stagnation pressure on one side and static pressure on the other in NASA's practical. Converting that difference to a flow speed additionally needs the hypotheses discussed under dynamic pressure and Pitot-static tube. A changing pressure can leave the column oscillating; leaks, blocked pressure tappings or trapped liquid in a gas connection can alter or delay the readout. The column should be read after settling, and temperature should be recorded when choosing the measuring liquid's mass density.
Two corrections clarify the limits. If both gas ports are at the same height and carry the same gas of constant mass density , keeping its hydrostatic pressure gives . Different port heights require their separate gas column heights. Also, a curved liquid meniscus can sustain a capillary pressure jump through surface tension. Write for liquid pressure minus gas pressure at the two surfaces. Neglecting gas weight, the balance becomes . Identical meniscus shapes in matching clean bores cancel those jumps; unequal bores or different wetting conditions need not. Thus the useful simplicity of rests on identifiable physical conditions.
Wind-fed black-hole binary Created 2026-10-20 Updated 2026-10-25
A binary in which a black hole captures part of its companion's stellar wind. The captured gas can dissipate energy and, with sufficient specific angular momentum, form an accretion disk. This differs from gas overflowing a Roche lobe through the inner Lagrange point. The fraction captured, its angular momentum and changes in the wind affect the accretion flow and emitted X-rays.
X-ray Created 2026-10-14 Updated 2026-10-18
X-rays are high-frequency electromagnetic radiation, conventionally with wavelengths of roughly to . The precise wavelength convention varies with context. Hot accreting gas and energetic electronic processes can emit X-rays, whose short wavelengths make them useful probes of compact objects and electron shells.
For a photon, , where is the Planck constant and is the speed of light. As a calculated example, gives , using . The same wavelength can describe different production mechanisms: bremsstrahlung produces a continuous frequency spectrum, whereas Characteristic X-rays arise from discrete electronic changes in chemical atoms. Measuring transmitted X-rays gives radiography; measuring their frequency spectrum gives spectroscopy.
Yair Segev 2026-11-05
Yair Segev coauthored an experiment increasing molecular-beam brightness by suppressing a shock-wave mechanism. The study connects a source's gas dynamics with the useful directed particle flux, rather than assuming that a higher source input always gives a brighter beam.[ref]
Molecular beam brightening by shock-wave suppression by Yair Segev and others. author list and the described study’s abstract or introductory account
Young–Laplace equation Created 2026-09-24 Updated 2026-10-14
The Young–Laplace equation relates the pressure jump across a stationary interface to its curvature and surface tension. Choose a unit normal vector pointing from the inside region to the outside region, and define to be positive for a convex sphere. In mechanical equilibrium, with constant surface tension and no additional normal viscous stresses,Here are the signed principal curvatures in this convention. Their sum is twice the corresponding signed mean curvature; stating the convention prevents a factor-of-two ambiguity. The Young–Laplace equation is a local normal stress balance for one interface. [ref]
https://arxiv.org/html/2011.11403v2. Tomas Bohr and Bernhard Scheichl, Surface Tension and Energy Conservation in a Moving Fluid, equations (8)–(9)
A spherical liquid droplet of radius in a gas has one interface, with . An ideal thin soap bubble has two liquid–gas interfaces. Adding their pressure jumps givesFor the soap bubble, now means the inner gas pressure minus the outer gas pressure. The second formula assumes equal surface tensions on both faces and film thickness negligible relative to , so their radii can be identified. Retaining distinct radii gives . A gas bubble inside bulk liquid has only one interface and therefore uses . [ref]
With the assumed constant toy surface tension , a droplet with has excess pressure ; at it has . A thin soap bubble assigned the same and has excess pressure . These are differences from the surrounding pressure, rather than absolute pressures. Halving the radius doubles the capillary pressure; doubling the interface count also doubles it at fixed radius and surface tension.
Smaller droplets need larger excess pressure; two bubble interfaces double it
. Left: a virtual outward displacement of a sphere balances pressure work against increased surface energy. Right: excess pressure in pascals versus positive radius in millimetres for one and two interfaces, using the assumed constant toy . Details.The spherical case has a short work argument. A virtual increase in radius gives and . At mechanical equilibrium, the net pressure work balances the increase in surface energy:For a thin soap bubble, both interfaces gain approximately the same surface area, doubling the right-hand side and giving . This is a virtual work balance between neighboring spherical configurations, rather than an assumption that a fixed-volume droplet actually expands. The general Young–Laplace equation replaces the spherical area-to-volume ratio by local curvature, making geometry directly measurable through pressure.